Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] V20z Server: Hardware Specifications

Processor
Number 1 or 2
Architecture AMD Opteron Processor 200 Series
242 (1.6GHz), 244 (1.8GHz), 270 (2.0GHz), 248 (2.2GHz), 275 (2.2GHz), 250 (2.4GHz), 252 (2.6GHz)
Cache memory 1 MB Level 2
Main Memory
Capacities 4 DIMM slots per processor, 8 total slots per System Board
DDR1/333 ECC registered DIMMs (128 bit plus ECC databus)

512-MB, 1-GB, or 2-GB expansion (16GB maximum when configured with 2 processors)
Standard Integrated Interfaces
Network Two 10/100/1000Base-T Ethernet ports
Network Management One dedicated 10/100Base-T Ethernet port with integrated 2 ports switch for daisy-chaining
Serial One TIA/EIA-232-F asynchronous DB-9 port
SCSI Single Ultra320 SCSI interface, internal access only. No external SCSI port.
USB One USB 1.1 port
Expansion bus Two internal PCI-X slots
  • one full-length at 64-bit/133MHz (slot 0)
  • one half-length at 64-bit/66MHz (slot 1)
Internal Mass Storage
Disks Up to two hot-swap Ultra320 SCSI Disks (36 or 73 GB, 10K RPM)
DVD or CD-ROM One Slim-line ATAPI DVD-ROM/Floppy or CD-ROM/Floppy (optional)
Power Supplies
One power supply, maximum AC output 465W
Environment
AC power 90-264 V AC (47-63 Hz)
Temperature Single, non-rack system:
Operating: 10° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F)
Humidity Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing, 38° C (100.4° F) max wet bulb
Altitude Single, non-rack system:
Operating: up to 3000 m (10,000 ft.), maximum ambient temperature is derated by 1° C per 500 m above 500 m
Nonoperating: up to 12,000 m (40,000 ft.)
Acoustic noise Single, non-rack system:
Less than 6.7 B sound power in ambient temperature of up to 24° C
Vibration Single, non-rack system:
.20 G, 5 to 500 Hz sine sweep
Shock Single, non-rack system:
5 G, 11 ms half-sine
Regulations
Meets or exceeds the following requirements:
Safety IEC60950, UL/CSA60950, EN60950
RFI/EMI FCC Class A, Part 15 47 CFR, EN55022, CISPR 22
Immunity EN55024
Certifications Safety: cULus Mark, TUV GS Mark, CE Mark
EMC: CE Mark (93/68/EEC), FCC authorized Class A, VCCI, BSMI, CTICK
Dimensions and Weight
Height 43 mm (1.69 in.)
Width 430 mm (16.94 in.)
Depth 724 mm (28.5 in.)
Weight 16 kg (35 lb.) (with packaging)
Enclosure

The Sun Fire V20z server can be mounted in industry standard 19-inch equipment racks. (The new Compute Grid rack system base and Sun Fire V20z compute servers will enable the installation of 32 1U units in the Sun Rack 1000-38.)

The optional slide rail kit (X9267A, backward-compatible with X9274A) is designed to enable Sun Fire V20z servers to be racked in a Sun Rack 1000-38 (also known as Sun Rack 1038) and third party EIA 310D compliant racks which have mounting depths of 27-30 inches. Please note that not all third party racks meet these parameters. The slides are useable on racks with a rail-to-rail spacing of 26.88-30.63 inches.

The Sun Rack 1038 rail spacing, for example, is 27.00 inches. The slide kit will include hardware that enables mounting to any of the following types of rack rails:
6 mm threaded holes
#10-32 threaded holes
#10 clearance holes

The optional slide rail kit (X9267A) is a 4-point mounted slide rail kit only. No other kits will be available to allow 2-point, front-mount, nor mid-mount configuration.


  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback