Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] T2000 Server: Hardware Specifications

Processor
Number 1
Architecture 1.0/1.2-GHz UltraSPARC T1 Chip Multithreaded (CMT)
1.2 GHz is 8 core
1.0 GHz are 4, 6 or 8-core
CoolThreads Server
ECO-Responsible Server
Cache memory 3 MB unified level 2 cache with ECC
Main Memory
Capacities DIMM slots per memory controller: 4
DIMM type: DDR2 ECC registered DIMMs
DIMM size: 512-MB, 1-GB, 2-GB, or 4-GB
Maximum capacity: 64GB (when configured with 4-GB DIMMs)
Note: DIMMS must be installed in sets of 8. Two basic memory configurations are supported: 8-DIMM or 16-DIMM. All DIMMs must have identical capacity. An 8 DIMM configuration fully populates Rank 0 slots.
Standard Integrated Interfaces
Network Four 10/100/1000 Base-T Ethernet autonegotiating ports
Network Management One dedicated 10/100Base-T Ethernet port
Remote Management SC Serial Management port and Net Management port
USB Front:Two USB 1.1 ports
Rear:Two USB 1.1 ports
PCI Interfaces Three PCI-Express (PCI-E) low-profile, 2.5GHz lanes card slots with up to X8 data lanes.
Two PCI-X low-profile, 64-bit, 133 MHz card slots.
Note: One PCI-X (slot 0) is occupied by a SAS disk controller card.
Internal Storage
Disks Up to four 73GB or 146GB HDD Disks (Hot Pluggable, SFF, SAS, 10K RPM).
Removable Media 1 slimline DVD-R/CD-RW drive
Power Supplies
The Sun Fire T2000 has two autoranging, 550W (N+1), hot-swappable power supplies. To ensure redundant operation of the power supplies, the two power cords should be connected to separate AC circuits. These are the electrical limits and ranges for the Sun Fire T2000 server utilizing 550 W power supplies:
Operating input voltage range 100 to 240 VAC, 50-60 Hz
Maximum operating input current 4.0 A at 100 to 120 VAC
2.0 A at 200 to 240 VAC
Maximum operating input power 400 W
Maximum heat dissipation 1,365 BTU/hr
Nominal Power 325 W
Space, Watts and Performance (SWaP)
Space (RU) 2
Watts 300
Performance (application tier benchmark) 5300
Performance/watt 17.667
SWaP 8.8
Environment
Temperature Operating (Sea Level to 3000 ft(900m)): 5° C to 35° C (41° F to 95° F)
Non-operating: -40° C to 60° C (-40° F to 140° F)
Operating (Above 3000 ft(900m)):Decrease maximum temperature as altitude increases, 1.6°F/1000 ft (1°C/300m)
Non-operating: -40° C to 60° C (-40° F to 140° F)
Humidity Operating: 20% to 80% relative humidity noncondensing, 27° C (80.6° F) web bulb, IEC 60068-2-3&56
Non-operating: 98% relative humidity 38° C (100.4 ° F) noncondensing,IEC 60068-2-3&56
Altitude Operating: up to 3000 m (10,000 ft.), IEC 60068-2-13
Non-operating: up to 12,000 m (40,000 ft.), IEC 60068-2-13
Acoustic noise - LPAm (bystander positions) Operating: 62 dB
Idling: 62 dB
Acoustic noise - LwAd (1 B = 10 dB) Operating: 7.7 B
Idling: 7.7 B
Vibration Operating: 0.2 Gs, Swept sine 5-500-5Hz, 1 octave/min, all axes, IEC 60068-2-13
Non-operating: 1.0 Gs, Swept sine 5-500-5Hz, 1 octave/min, all axes, IEC 60068-2-13
Shock Operating: 5.0 Gs peak 11 msec, half-sine pulse, IEC 60068-2-27
Non-operating: 30.0 Gs peak 11 msec, half-sine pulse, IEC 60068-2-27
Cooling 3 hot-swappable and redundant system fans.
1 hot-swappable blower unit.
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC 825-1,2, CFR21 part 1040, CNS 14336, GB4943
Ergonomics EK1-1TB-2000
RFI/EMI EN55022 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NC 3548 Class A, CNS 13438 Class A, KSC 5858 Class A, GB9254 Class A, EN61000-3-2, GB17625.1, EN61000-3-3
Immunity EN55024, IEC 61000-2, IEC 61000-3, IEC 61000-4, IEC 61000-5, IEC 61000-6, IEC 61000-8, IEC 61000-11
Telecommunications EN300-386
Regulatory Markings (pending) CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/DEMKO/GS, UL/S-mark, CCC
Dimensions and Weight
Height (2 rack units) 89 mm (3.5 in.)
Width 425 mm (16.7 in.)
Depth 617 mm (24.3 in.)
Weight, approximate (without PCI cards and rack mounts) 18 kg (40 lb.)
Clearance and Service Access
Front 91 cm (36 in.)
Rear 91 cm (36 in.)
Rack Mounting
SR900-38 Sun Rack 900 - 38 (alloy)
SR900-36N Sun Rack 900 - 36N (alloy)
Sr1000-38 Sun Rack 1000 - 38 (alloy)
SR1000-42 Sun Rack 1000 - 42 (alloy)
SG-XARY030A Sun StorEdge 72-inch expansion cabinet
Sun Fire cabinet

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback