Processor |
Number |
Two to 24 |
Architecture |
UltraSPARC[tm] III: 750MHz
UltraSPARC III Cu (copper based): 900MHz, 1050MHz or 1200MHz
UltraSPARC IV: 1050MHz, 1200MHz or 1350MHz
UltraSPARC IV+: 1.5GHz or 1.8GHz |
Cache per processor |
UltraSPARC III and III CU:
Primary (L1): 32 KB instruction, and 64 KB data cache
Secondary (L2): 8 MB, ECC protected
UltraSPARC IV:
Primary (L1): 64 KB 4-way data, 32 KB 4-way instruction, 2 KB Write, 2 KB Prefetch
Secondary (L2): 16 MB external (exclusive access to 8 MB per pipeline), On-chip controller and address tags
UltraSPARC IV+:
Primary (L2): 2 MB on-chip
Secondary (L3): 32 MB off-chip
|
CPU interface |
Packet-switch crossbar connecting up to 6 CPU/Memory boards, and up to
4 I/O assemblies |
System Interconnect |
Fireplane, 9.6 GB/sec (at 150 MHz) |
System
Boards |
Number of boards |
Maximum of 6 CPU/Memory boards and 4 I/O assemblies |
CPU/Memory board |
Two CPU's with 32 GB (max) Memory or four CPU's with 64 GB (max) memory |
PCI I/O Assembly |
Eight PCI slots supporting:
6 full or short cards
4 at 33 MHz, 5V (slots 2, 4, 5, 6)
2 at 33/66 MHz, 3.3V (slots 3, 7)
2 short boards
33 MHz, 5V (slots 0 and 1)
|
CompactPCI I/O Assembly |
Four CompactPCI slots supporting 4-3U cPCI cards
2 at 33/66 MHz, 3.3V (slot 0 and 1)
2 at 33 MHz, 5V (slots 2 and 3)
|
PCI-X I/O Assembly |
Eight 64-bit PCI-X slots
6 at 100 MHz
2 at 33 MHz
|
Main
Memory |
64 GB memory (max) per 4 CPU's or 32 GB memory (max) per 2
CPU's on a CPU/Memory board
Maximum system memory capacity of 384 GB (6 × 64 GB)
1GB DIMMs are not supported on 750MHz CPU/Memory boards.
Note: The UltraSPARC III processor contains an integrated memory controller
which is responsible for memory management of local memory and for running
diagnostics on the CPU/Memory board. Therefore, memory capacity is directly
related to the number of CPU's.
|
Standard
Interfaces |
System Controller |
Responsible for the overall control of the system. Each System Controller
includes one RS-232/423 (DB25)
serial interface and one 10/100BASE-T ethernet/fast ethernet (RJ45)
interface. Dual system controllers are standard on the Sun Fire 6800. |
Internal
Mass Storage |
Sun StorEdge[tm] D240 Media Tray |
A 2U-high, rack-mounted unit into which two UltraWide SCSI3 disk drive,
and one DVD drive and one DDS4 tape drive can be fitted. The DVD and DDS4
devices can be replaced by extra disk drives if required. Up to 3 - D240
trays can be installed into the Sun Fire 6800 cabinet. |
Power
Supplies |
The Sun Fire 3800-6800 server family can be configured with
N"4" redundant DC bulk power supplies, which are hot swappable. The DC bulk
power supplies provide power for all of the Sun Fire 3800-6800 systems'
internal requirements, on a load-shared 48VDC power bus. The base package
comes with 6 power supplies. |
Environment |
AC power |
200 - 240 VAC, 47 - 63 Hz, 34 A with 2 RTS |
Input power |
6,460 W |
Heat output |
22,030 BTU/hr |
Temperature |
Optimal: 21° C to 23° C (70° F to 73.5° F)
Operating: 5° C to 35° C (41° F to 95° F) - derate
2° C for every 1 km up to 3 km
Nonoperating: -20° C to 60° C (-4° F to 140° F) |
Humidity |
Optimal: 45% to 50% relative humidity
Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing |
Acoustic noise |
69 dB(A) |
Vibration |
Operating: 0.15 G, 5 to 500Hz, swept sine
Nonoperating: 0.6 G, 5 to 500Hz, swept sine, vertical
0.3 G, 5 to 500Hz, swept sine, horizontal |
Shock |
Operating: 3 G, 11 ms, half sine |
Number of cords1 |
2 or 4 (dual power grid feature) |
1 One power cord
for each RTS installed. Minimum required is two and maximum is four. |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL 1950, CSA C22.2 950, TUB EN60950, CB Scheme (Worldwide Deviation) |
RFI/EMI |
FCC Class A, ICES 003 Class A, DOC Class A, EN55022 Class A, VCCI Class
A, BSMI Class A, EN61000-3-2 & EN61000-3-3 |
Immunity |
EN55024, EN50082-1 |
Dimensions
and Weights |
Height |
75.00 in, 190.5 cm |
Width |
24.00 in, 61.0 cm |
Depth |
53.00 in, 134.6 cm |
Weight, main cabinet |
1000 lbs, 454 kg |
Power Cord |
180 in (15 ft), 457.2 cm (4.6 m) |
Clearance
and Service Access |
Front |
4 ft (122 cm) |
Rear |
3 ft (91.4 cm) |
Right |
0 clearance during operation* |
Left |
0 clearance during operation* |
* To access and remove side panels, allow approximately 2
ft (60 cm.) of space on the sides. For any peripheral tray in the processor
cabinet OVER 508 mm (20 in) in length, allow additional space for access
to the doors on the side where the peripheral will be loaded. |