Processor |
Number |
Two to 12 |
Architecture |
UltraSPARC[tm] III: 750MHz
UltraSPARC III Cu (copper based): 900MHz, 1050MHz or 1200MHz
UltraSPARC IV (SF 4800 only): 1050MHz, 1200MHz, or 1350MHz
UltraSPARC IV+ (SF 4800 only): 1.5GHz or 1.8GHz |
Cache per processor |
UltraSPARC III and III CU:
Primary (L1): 32 KB instruction, and 64 KB data cache
Secondary (L2): 8 MB, ECC protected
UltraSPARC IV:
Primary (L1): 64 KB 4-way data, 32 KB 4-way instruction, 2 KB Write, 2 KB Prefetch
Secondary (L2): 16 MB external (exclusive access to 8 MB per pipeline), On-chip controller and address tags
UltraSPARC IV+:
Primary (L2): 2 MB on-chip
Secondary (L3): 32 MB off-chip
|
CPU interface |
Packet-switch crossbar connecting up to
3 CPU/Memory boards, and up to 2 I/O assemblies |
System Interconnect |
Fireplane, 9.6 GB/sec (at 150 MHz) |
System
Boards |
Number of boards |
Maximum of 3 CPU/Memory boards and 2 I/O
assemblies |
CPU/Memory board |
Two CPU's with 32 GB (max) Memory or four
CPU's with 64 GB (max) memory |
PCI I/O Assembly |
Eight PCI slots supporting:
6 full or short cards
4 at 33 MHz, 5V (slots 2, 4, 5, 6)
2 at 33/66 MHz, 3.3V (slots 3, 7)
2 short boards
33 MHz, 5V (slots 0 and 1)
|
CompactPCI I/O Assembly |
Four CompactPCI slots supporting 4-3U cPCI cards
2 at 33/66 MHz, 3.3V (slot 0 and 1)
2 at 33 MHz, 5V (slots 2 and 3)
|
PCI-X I/O Assembly |
Eight 64-bit PCI-X slots
6 at 100 MHz
2 at 33 MHz
|
Main Memory |
64 GB memory (max) per 4 CPU's or 32 GB memory (max) per 2
CPU's on a CPU/Memory board
Maximum system memory capacity of 192 GB (3 × 64 GB)
1GB DIMMs are not supported on 750MHz CPU/Memory boards.
Note: The UltraSPARC III processor contains an integrated memory controller
which is responsible for memory management of local memory and for running
diagnostics on the CPU/Memory board. Therefore, memory capacity is directly
related to the number of CPU's.
|
Standard
Interfaces |
System Controller |
Responsible for the overall control of the
system. Each System Controller includes one RS-232/423 (DB25)
serial interface and one 10/100BASE-T ethernet/fast ethernet (RJ45)
interface. Dual system controllers are standard on the Sun Fire 6800. |
Internal
Mass Storage |
Sun StorEdge[tm] D240 Media Tray |
A 2U-high, rack-mounted unit into which
two UltraWide SCSI3 disk drive, and one DVD drive and one DDS4 tape drive
can be fitted. The DVD and DDS4 devices can be replaced by extra disk drives
if required. Up to 2 - D240 trays can be installed into the Sun Fire 4800/4810
cabinet. |
Power
Supplies |
The Sun Fire 3800-6800 server family can
be configured with N"4" redundant DC bulk power supplies, which are hot
swappable. The DC bulk power supplies provide power for all of the Sun Fire
3800-6800 systems' internal requirements, on a load-shared 48VDC power bus.
The base package comes with 2 power supplies. |
Environment |
4800 |
4810 |
AC input |
200-240 VAC, 47-63 Hz, 16A at 208 VAC for each power cord (2+1 redundancy)(maximum) |
200 - 240 VAC, 47 - 63 Hz, 16A at 208 VAC for each power cord (2+1 redundancy)(maximum) |
Input power |
3,040 W |
3,120 W |
Heat output |
10,370 BTU/hr |
10,625 BTU/hr |
Temperature |
Optimal: 21° C to 23° C (70°
F to 73.5° F)
Operating: 5° C to 35° C (41° F to 95° F) - derate
2° C for every 1 km up to 3 km
Nonoperating: -20° C to 60° C (-4° F to 140° F)
|
Optimal: 21° C to 23° C (70°
F to 73.5° F)
Operating: 5° C to 35° C (41° F to 95° F) - derate
2° C for every 1 km up to 3 km
Nonoperating: -20° C to 60° C (-4° F to 140° F)
|
Humidity |
Optimal: 45% to 50% relative humidity
Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing |
Optimal: 45% to 50% relative humidity
Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing |
Altitude |
Operating: 3000 m (10,000 ft.)
Nonoperating: 12,000 m (40,000 ft.) |
Operating: 3000 m (10,000 ft.)
Nonoperating: 12,000 m (40,000 ft.) |
Acoustic noise |
69 dB(A) |
69 dB(A) |
Vibration |
Operating: 0.15 G, 5 to 500Hz, swept sine
Nonoperating: 0.6 G, 5 to 500Hz, swept sine, vertical
0.3 G, 5 to 500Hz, swept sine, horizontal |
Operating: 0.15 G, 5 to 500Hz, swept sine
Nonoperating: 0.6 G, 5 to 500Hz, swept sine, vertical
0.3 G, 5 to 500Hz, swept sine, horizontal |
Shock |
Operating: 3 G, 11 ms, half sine |
Operating: 3 G, 11 ms, half sine |
Number of cords1 |
Deskside: 3
Rack Mounted: See specific rack information in Components area of the Sun System Handbook |
Deskside: 3
Rack Mounted: See specific rack information in Components area of the Sun System Handbook |
1 One power cord
for each power supply installed. Minimum required is two and maximum is
three. |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL 1950, CSA C22.2 950, TUB EN60950, CB
Scheme (Worldwide Deviation) |
RFI/EMI |
FCC Class A, ICES 003 Class A, DOC Class
A, EN55022 Class A, VCCI Class A, BSMI Class A, EN61000-3-2 & EN61000-3-3 |
Immunity |
EN55024, EN50082-1 |
Dimensions and Weights |
4800 |
4810 |
Height |
32.40 in, 82.3 cm (deskside)
30.00 in, 76.2 cm (rack-mount) |
36.75 in, 93.4 cm |
Width |
18.90 in, 48.1 cm (deskside)
17.56 in, 44.6 cm (rack-mount) |
17.56 in, 44.6 cm |
Depth |
34.20 in, 86.9 cm (deskside)
28.50 in, 72.4 cm (rack-mount) |
23.62 in, 60.0 cm |
Weight |
290 lbs, 131 kg (deskside)
275 lbs, 125 kg (rack-mount) |
290 lbs, 132 kg |
Clearance and Service Access
(4800/4810 Rack-mounted) |
Front |
4 ft (121 cm) |
Rear |
3 ft (91 cm) |
Right |
0 clearance during operation* |
Left |
0 clearance during operation* |
* To access and remove side panels, allow
approximately 2 ft (60 cm.) of space on the sides. |
Clearance and Service Access
(4800 Deskside) |
Front |
3 ft (91 cm) |
Rear |
3 ft (91 cm) |
Right |
1 in (25 mm) |
Left |
1 in (25 mm) |
Rack |
4800: Fits into standard 19-inch
wide, 36-inch deep commercial racks.
4810: Fits into 19 inch wide, 30 inch racks. |