Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] 4800/4810 Server: Hardware Specifications

Processor
Number Two to 12
Architecture UltraSPARC[tm] III: 750MHz
UltraSPARC III Cu (copper based): 900MHz, 1050MHz or 1200MHz
UltraSPARC IV (SF 4800 only): 1050MHz, 1200MHz, or 1350MHz
UltraSPARC IV+ (SF 4800 only): 1.5GHz or 1.8GHz
Cache per processor UltraSPARC III and III CU:
Primary (L1): 32 KB instruction, and 64 KB data cache
Secondary (L2): 8 MB, ECC protected
UltraSPARC IV:
Primary (L1): 64 KB 4-way data, 32 KB 4-way instruction, 2 KB Write, 2 KB Prefetch
Secondary (L2): 16 MB external (exclusive access to 8 MB per pipeline), On-chip controller and address tags
UltraSPARC IV+:
Primary (L2): 2 MB on-chip
Secondary (L3): 32 MB off-chip
CPU interface Packet-switch crossbar connecting up to 3 CPU/Memory boards, and up to 2 I/O assemblies
System Interconnect Fireplane, 9.6 GB/sec (at 150 MHz)
System Boards
Number of boards Maximum of 3 CPU/Memory boards and 2 I/O assemblies
CPU/Memory board Two CPU's with 32 GB (max) Memory or four CPU's with 64 GB (max) memory 
PCI I/O Assembly Eight PCI slots supporting:
  6 full or short cards
4 at 33 MHz, 5V (slots 2, 4, 5, 6)
2 at 33/66 MHz, 3.3V (slots 3, 7)
  2 short boards
33 MHz, 5V (slots 0 and 1)
CompactPCI I/O Assembly Four CompactPCI slots supporting 4-3U cPCI cards
2 at 33/66 MHz, 3.3V (slot 0 and 1)
2 at 33 MHz, 5V (slots 2 and 3)
PCI-X I/O Assembly Eight 64-bit PCI-X slots
6 at 100 MHz
2 at 33 MHz
Main Memory
64 GB memory (max) per 4 CPU's or 32 GB memory (max) per 2 CPU's on a CPU/Memory board

Maximum system memory capacity of 192 GB (3 × 64 GB)

1GB DIMMs are not supported on 750MHz CPU/Memory boards.

Note: The UltraSPARC III processor contains an integrated memory controller which is responsible for memory management of local memory and for running diagnostics on the CPU/Memory board. Therefore, memory capacity is directly related to the number of CPU's.

Standard Interfaces
System Controller Responsible for the overall control of the system. Each System Controller includes one RS-232/423 (DB25) serial interface and one 10/100BASE-T ethernet/fast ethernet (RJ45) interface. Dual system controllers are standard on the Sun Fire 6800.
Internal Mass Storage
Sun StorEdge[tm] D240 Media Tray A 2U-high, rack-mounted unit into which two UltraWide SCSI3 disk drive, and one DVD drive and one DDS4 tape drive can be fitted. The DVD and DDS4 devices can be replaced by extra disk drives if required. Up to 2 - D240 trays can be installed into the Sun Fire 4800/4810 cabinet.
Power Supplies
The Sun Fire 3800-6800 server family can be configured with N"4" redundant DC bulk power supplies, which are hot swappable. The DC bulk power supplies provide power for all of the Sun Fire 3800-6800 systems' internal requirements, on a load-shared 48VDC power bus. The base package comes with 2 power supplies.
Environment 4800 4810
AC input 200-240 VAC, 47-63 Hz, 16A at 208 VAC for each power cord (2+1 redundancy)(maximum) 200 - 240 VAC, 47 - 63 Hz, 16A at 208 VAC for each power cord (2+1 redundancy)(maximum)
Input power 3,040 W 3,120 W
Heat output 10,370 BTU/hr 10,625 BTU/hr
Temperature Optimal: 21° C to 23° C (70° F to 73.5° F)
Operating: 5° C to 35° C (41° F to 95° F) - derate 2° C for every 1 km up to 3 km
Nonoperating: -20° C to 60° C (-4° F to 140° F)
Optimal: 21° C to 23° C (70° F to 73.5° F)
Operating: 5° C to 35° C (41° F to 95° F) - derate 2° C for every 1 km up to 3 km
Nonoperating: -20° C to 60° C (-4° F to 140° F)
Humidity Optimal: 45% to 50% relative humidity
Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing
Optimal: 45% to 50% relative humidity
Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing
Altitude Operating: 3000 m (10,000 ft.)
Nonoperating: 12,000 m (40,000 ft.)
Operating: 3000 m (10,000 ft.)
Nonoperating: 12,000 m (40,000 ft.)
Acoustic noise 69 dB(A) 69 dB(A)
Vibration Operating: 0.15 G, 5 to 500Hz, swept sine
Nonoperating: 0.6 G, 5 to 500Hz, swept sine, vertical
0.3 G, 5 to 500Hz, swept sine, horizontal
Operating: 0.15 G, 5 to 500Hz, swept sine
Nonoperating: 0.6 G, 5 to 500Hz, swept sine, vertical
0.3 G, 5 to 500Hz, swept sine, horizontal
Shock Operating: 3 G, 11 ms, half sine Operating: 3 G, 11 ms, half sine
Number of cords1 Deskside: 3
Rack Mounted: See specific rack information in Components area of the Sun System Handbook
Deskside: 3
Rack Mounted: See specific rack information in Components area of the Sun System Handbook
1 One power cord for each power supply installed. Minimum required is two and maximum is three.
Regulations
Meets or exceeds the following requirements:
Safety UL 1950, CSA C22.2 950, TUB EN60950, CB Scheme (Worldwide Deviation)
RFI/EMI FCC Class A, ICES 003 Class A, DOC Class A, EN55022 Class A, VCCI Class A, BSMI Class A, EN61000-3-2 & EN61000-3-3
Immunity EN55024, EN50082-1
Dimensions and Weights 4800 4810
Height 32.40 in, 82.3 cm (deskside)
30.00 in, 76.2 cm (rack-mount)
36.75 in, 93.4 cm
Width  18.90 in, 48.1 cm (deskside)
17.56 in, 44.6 cm (rack-mount)
17.56 in, 44.6 cm
Depth  34.20 in, 86.9 cm (deskside)
28.50 in, 72.4 cm (rack-mount)
23.62 in, 60.0 cm
Weight  290 lbs, 131 kg (deskside)
275 lbs, 125 kg (rack-mount)
290 lbs, 132 kg
Clearance and Service Access (4800/4810 Rack-mounted)
Front 4 ft (121 cm)
Rear 3 ft (91 cm)
Right 0 clearance during operation*
Left 0 clearance during operation*
* To access and remove side panels, allow approximately 2 ft (60 cm.) of space on the sides.
Clearance and Service Access (4800 Deskside)
Front 3 ft (91 cm)
Rear 3 ft (91 cm)
Right 1 in (25 mm)
Left 1 in (25 mm)
Rack
4800: Fits into standard 19-inch wide, 36-inch deep commercial racks.
4810: Fits into 19 inch wide, 30 inch racks.

   
  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.