VMEbus Bus Grant and Interrupt Acknowledge

This chart shows how the Bus Grant In/Out and Interrupt Acknowledge In/Out signals are connected on the board. Wired signals are not used. Open signals are selected with backplane jumpers. Option signals are enabled on the board and on the backplane.

DESCRIPTION BG0 BG1 BG2 BG3 IACK
4100 CPU Wired Wired Wired Open Wired
4200 CPU Wired Wired Wired Open Wired
4300 CPU Wired Wired Wired Open Open
4400 CPU Wired Wired Wired Open Wired
600MP CPU Wired Wired Wired Open Open
CG2 Color Wired Wired Wired Wired Open
CG3 Color Wired Wired Wired Wired Open
CG5 Color Wired Wired Wired Wired Open
CG9 Color Wired Wired Wired Wired Open
GB Wired Wired Wired Wired Wired
GP & GP+ Wired Wired Wired Open Open
GP2 Wired Wired Wired Wired Wired
TAAC-1 Wired Wired Wired Wired Open
VX Open Open Open Open Open
MVX Wired Wired Wired Open Open
3/E Mono Wired Wired Wired Wired Wired
3/E Color Wired Wired Wired Wired Wired
VME-Multibus Wired Wired Wired Open Open
Xylogics 7053 Option Option Option Option Open
ISP-80 IPI-2 Open Open Open Open Open
Prestoserve Wired Wired Wired Wired Wired
ALM-2 Wired Wired Wired Wired Open
MCP Wired Wired Wired Wired Open
HSI Wired Wired Wired Wired Open
Channel Adapter Option Option Option Option
FDDI Wired Open Open Open Open
SCSI-2 Option Option Option Option Open
SCSI-3 Wired Wired Wired Open Open
3/E SCSI Wired Wired Wired Wired Open
IPC Open Open Open Open Open



Last updated: December 2, 1996
  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback