Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun-4/280

with 501-1167 SCSI Host Adapter

SHUNTS BOARD SLOT POSITION
BG3 IACK 1 2 3 4 5 6 7 8 9 10 11 12
Out Out Sun 4200 CPU A










In In 1st Memory (6)




A





In In 2nd Memory (6)
A









In In 3rd Memory (6)

A








In In 4th Memory (6)


A







Out Out GP (4)








A

In In GB









A
In
In
In
In
In
In
TAAC-1 (5)
E F
E
F
E
F
D C
D
B
C
D
A
B
C
A
B
A
Out Out 1st ALM-1










A
Out Out 2nd ALM-1









A
Out Out 3rd ALM-1








A

Out Out SCSI (11)





A




In Out 1st MCP
A B C D






In Out 2nd MCP

A B C

D



In Out 3rd MCP


A B

C D


In Out 4th MCP



A

B C D E F
In Out 1st ALM-2
A B C D

E F G H I
In Out 2nd ALM-2

A B C

D E F G H
In Out 3rd ALM-2


A B

C D E F G
In Out 4th ALM-2



A

B C D E F
Out
Out
Out
Out
1st Channel
Adapter

A B
A
C
B
C

D E
D
F
E
G
F
G
Out
Out
Out
Out
2nd Channel
Adapter



A A

B C
B
D
C
E
D
E
Out
In
Out
In
1st MAPkit
A B
A
C
B
C

D E
D
F
E
G
F
G
Out
In
Out
In
2nd MAPkit


A A

B C
B
D
C
E
D
E
In Out Color (2)
A B C D

E F G H I
In Out CG5 w GP/GP+
A B C D

E F


In Out CG5 w GP2









A B
In Out CG9 Color









A B
In Out 1st HSI
A B C D

E F G H I
In Out 2nd HSI

A B C

D E F G H
Out Out Ethernet
A B C D

E F G H I
Out Out 1st FDDI
A B C D

E F G H I
Out Out 2nd FDDI

A B C

D E F G H
In Out 1st IPC (3)
A B C D

E F G H I
In Out 2nd IPC (3)

A B C

D E F G H
In Out 3rd IPC (3)


A B

C D E F G
In Out 4th IPC (3)



A

B C D E F
Out Out 1st Tape Ctlr (8)






A B C D E
Out Out 2nd Tape Ctlr (8)







A B C D
Out Out 1st Disk Ctlr (9)






A B C D E
Out Out 2nd Disk Ctlr (9)







A B C D
Out Out 3rd Disk Ctlr (10)








A B C
Out Out 4th Disk Ctlr (10)









A B

References

  1. Sun Systems Cardcage Slot Assignments and Backplane Configuration Procedures, 813-2004-16.
  2. Sun-4/200 Cardcage Slot Assignments and Backplane Configuration Procedures, 813-2037-05.

Sun-4/280

with Double-Height Backpanel
with 501-1167 SCSI Host Adapter

SHUNTS BOARD SLOT POSITION
BG3 IACK 1 2 3 4 5 6 7 8 9 10 11 12
Out Out Sun 4200 CPU A A









In In 1st Memory (6)




A





In In 2nd Memory (6)
A









In In 3rd Memory (6)

A








In In 4th Memory (6)


A







Out Out GP (4)








A

In In GB









A
In
In
In
In
In
In
TAAC-1 (5)

E E E
D C
D
B
C
D
A
B
C
A
B
A
Out Out 1st ALM-1










A
Out Out 2nd ALM-1









A
Out Out 3rd ALM-1








A

Out Out SCSI (11)





A




In Out 1st MCP
A B C D






In Out 2nd MCP

A B C

D



In Out 3rd MCP


A B

C D


In Out 4th MCP



A

B C D E F
In Out 1st ALM-2
A B C D

E F G H I
In Out 2nd ALM-2

A B C

D E F G H
In Out 3rd ALM-2


A B

C D E F G
In Out 4th ALM-2



A

B C D E F
Out
Out
Out
Out
1st Channel
Adapter

A B
A
C
B
C

D E
D
F
E
G
F
G
Out
Out
Out
Out
2nd Channel
Adapter



A A

B C
B
D
C
E
D
E
Out
In
Out
In
1st MAPkit
A B
A
C
B
C

D E
D
F
E
G
F
G
Out
In
Out
In
2nd MAPkit


A A

B C
B
D
C
E
D
E
In Out Color (2)

A B C
D E F G H I
In Out CG5 w GP/GP+

A B C
D E F


In Out CG5 w GP2









A B
In Out CG9 Color









A B
In Out 1st HSI

A B C

D E F G H
In Out 2nd HSI


A B

C D E F G
Out Out Ethernet

A B C
D E F G H I
Out Out 1st FDDI

A B C

D E F G H
Out Out 2nd FDDI


A B

C D E F G
In Out 1st IPC (3)

A B C
D E F G H I
In Out 2nd IPC (3)


A B
C D E F G H
In Out 3rd IPC (3)



A
B C D E F G
In Out 4th IPC (3)





A B C D E F
Out Out 1st Tape Ctlr (8)





A B C D E F
Out Out 2nd Tape Ctlr (8)






A B C D E
Out Out 1st Disk Ctlr (9)





A B C D E F
Out Out 2nd Disk Ctlr (9)






A B C D E
Out Out 3rd Disk Ctlr (10)







A B C D
Out Out 4th Disk Ctlr (10)








A B C

References

  1. Sun Systems ardcage Slot Assignments and Backplane Configuration Procedures, 813-2004-16.
  2. Cardcage Slot Assignments and Backplane Configuration Procedures for Sun 4/200 Systems with Double-Height Backpanels, 813-2071-05.

Sun-4/280

with 501-1138 or 501-1217 SCSI

SHUNTS BOARD SLOT POSITION
BG3 IACK 1 2 3 4 5 6 7 8 9 10 11 12
Out Out Sun 4200 CPU A










In In 1st Memory (6)




A





In In 2nd Memory (6)
A









In In 3rd Memory (6)

A








In In 4th Memory (6)


A







Out Out GP (4)








A

In In GB









A
In
In
In
In
In
In
TAAC-1 (5)
E F
E
F
E
F
D C
D
B
C
D
A
B
C
A
B
A
Out Out 1st ALM-1










A
Out Out 2nd ALM-1









A
Out Out 3rd ALM-1








A

In Out 1st MCP
A B C D






In Out 2nd MCP

A B C
D




In Out 3rd MCP


A B
C D



In Out 4th MCP



A
B C D


In Out 1st ALM-2
A B C D
E F G H I J
In Out 2nd ALM-2

A B C
D E F G H I
In Out 3rd ALM-2


A B
C D E F G H
In Out 4th ALM-2



A
B C D E F G
Out
Out
Out
Out
1st Channel
Adapter

A B
A
C
B
C
C D
C
E
D
F
E
G
F
G
Out
Out
Out
Out
2nd Channel
Adapter



A A
B C
B
D
C
E
D
F
E
F
Out
In
Out
In
1st MAPkit
A B
A
C
B
C
D E
D
F
E
G
F
H
G
H
Out
In
Out
In
2nd MAPkit


A A
B C
B
D
C
E
D
F
E
F
In Out 1st HSI
D A B C
E F G H I J
In Out 2nd HSI
C
A B
D E F G H I
Out Out Ethernet
D A B C
E F G H I J
Out Out SCSI (12)
A B C D
E F G H I J
In Out Color (2)
A B C D
E F G H I J
In Out CG5 w GP/GP+
A B C D
E F G


In Out CG5 w GP2









A B
In Out CG9 Color









A B
In Out 1st HSI
A B C D
E F G H I J
In Out 2nd HSI

A B C
D E F G H I
Out Out Ethernet
A B C D
E F G H I J
Out Out 1st FDDI
A B C D
E F G H I J
Out Out 2nd FDDI

A B C
D E F G H I
In Out 1st IPC (3)
A B C D
E F G H I J
In Out 2nd IPC (3)

A B C
D E F G H I
In Out 3rd IPC (3)


A B
C D E F G H
In Out 4th IPC (3)



A
B C D E F G
Out Out 1st Tape Ctlr (8)
A B C D
E F G H I J
Out Out 2nd Tape Ctlr (8)

A B C
D E F G H I
Out Out 1st Disk Ctlr (9)
A B C D
E F G H I J
Out Out 2nd Disk Ctlr (9)

A B C
D E F G H I
Out Out 3rd Disk Ctlr (10)


A B
C D E F G H
Out Out 4th Disk Ctlr (10)



A
B C D E F G

References

  1. Sun Systems Cardcage Slot Assignments and Backplane Configuration Procedures, 813-2004-16.
  2. Sun-4/200 Cardcage Slot Assignments and Backplane Configuration Procedures, 813-2037-05.

Sun-4/280

with Double-Height Backpanel
with 501-1138 or 501-1217 SCSI

SHUNTS BOARD SLOT POSITION
BG3 IACK 1 2 3 4 5 6 7 8 9 10 11 12
Out Out Sun 4200 CPU A A









In In 1st Memory (6)




A





In In 2nd Memory (6)
A









In In 3rd Memory (6)

A








In In 4th Memory (6)


A







Out Out GP (4)








A

In In GB









A
In
In
In
In
In
In
TAAC-1 (5)

E E E
D C
D
B
C
D
A
B
C
A
B
A
Out Out 1st ALM-1










A
Out Out 2nd ALM-1









A
Out Out 3rd ALM-1








A

In Out 1st MCP

A B C
D




In Out 2nd MCP


A B
C D



In Out 3rd MCP



A
B C D


In Out 4th MCP





A B C D E F
In Out 1st ALM-2

A B C
D E F G H I
In Out 2nd ALM-2


A B
C D E F G H
In Out 3rd ALM-2



A
B C D E F G
In Out 4th ALM-2





A B C D E F
Out
Out
Out
Out
1st Channel
Adapter


A A
B
B
C D
C
E
D
F
E
G
F
G
Out
Out
Out
Out
2nd Channel
Adapter






A B
A
C
B
D
C
E
D
E
Out
In
Out
In
1st MAPkit

A B
A
B
C D
C
E
D
F
E
G
F
G
Out
In
Out
In
2nd MAPkit





A B
A
C
B
D
C
E
D
E
Out Out SCSI (12)

A B C
D E F G H I
In Out Color (2)

A B C
D E F G H I
In Out CG5 w GP/GP+

A B C
D E F


In Out CG5 w GP2









A B
In Out CG9 Color









A B
In Out 1st HSI

A B C
D E F G H I
In Out 2nd HSI


A B
C D E F G H
Out Out Ethernet

A B C
D E F G H I
Out Out 1st FDDI

A B C
D E F G H I
Out Out 2nd FDDI


A B
C D E F G H
In Out 1st IPC (3)

A B C
D E F G H I
In Out 2nd IPC (3)


A B
C D E F G H
In Out 3rd IPC (3)



A
B C D E F G
In Out 4th IPC (3)





A B C D E F
Out Out 1st Tape Ctlr (8)

A B C
D E F G H I
Out Out 2nd Tape Ctlr (8)


A B
C D E F G H
Out Out 1st Disk Ctlr (9)

A B C
D E F G H I
Out Out 2nd Disk Ctlr (9)


A B
C D E F G H
Out Out 3rd Disk Ctlr (10)



A
B C D E F G
Out Out 4th Disk Ctlr (10)





A B C D E F

References

  1. Sun Systems Cardcage Slot Assignments and Backplane Configuration Procedures, 813-2004-16.
  2. Cardcage Slot Assignments and Backplane Configuration Procedures for Sun 4/200 Systems with Double-Height Backpanels, 813-2071-05.

Sun-4/280

with 501-1138 or 501-1217 SCSI

Slots 7,8,9 reserved for non-Sun boards that use P2

SHUNTS BOARD SLOT POSITION
BG3 IACK 1 2 3 4 5 6 7 8 9 10 11 12
Out Out Sun 4200 CPU A










In In 1st Memory (6)




A





In In 2nd Memory (6)
A









In In 3rd Memory (6)

A








In In 4th Memory (6)


A







Out Out GP (4)








A

In In GB









A
In
In
In
In
In
In
TAAC-1 (5)
B C
B
C
B
C



A A A
Out Out 1st ALM-1










A
Out Out 2nd ALM-1









A
Out Out 3rd ALM-1








A

In Out 1st MCP
A B C D






In Out 2nd MCP

A B C



D E F
In Out 3rd MCP


A B



C D E
In Out 4th MCP



A



B C D
In Out 1st ALM-2
A B C D



E F G
In Out 2nd ALM-2

A B C



D E F
In Out 3rd ALM-2


A B



C D E
In Out 4th ALM-2



A



B C D
Out
Out
Out
Out
1st Channel
Adapter

A B
A
C
B
C



D E
D
E
Out
Out
Out
Out
2nd Channel
Adapter



A A



B C
B
C
Out
Out
Out
Out
1st MAPkit
A B
A
C
B
C



D E
D
E
Out
Out
Out
Out
2nd MAPkit


A A



B C
B
C
Out In SCSI (12)
A B C D



E F G
In Out Color (2)
A B C D



E F G
In Out CG5 w GP/GP+
A B C D






In Out CG5 w GP2









A B
In Out CG9 Color









A B
In Out 1st HSI
A B C D



E F G
In Out 2nd HSI

A B C



D E F
Out Out Ethernet
A B C D



E F G
Out Out 1st FDDI
A B C D



E F G
Out Out 2nd FDDI

A B C



D E F
In Out 1st IPC (3)
A B C D



E F G
In Out 2nd IPC (3)

A B C



D E F
In Out 3rd IPC (3)


A




C D E
In Out 4th IPC (3)



A



B C D
Out Out 1st Tape Ctlr (8)
A B C D



E F G
Out Out 2nd Tape Ctlr (8)

A B C



D E F
Out Out 1st Disk Ctlr (9)
A B C D



E F G
Out Out 2nd Disk Ctlr (9)

A B C



D E F
Out Out 3rd Disk Ctlr (10)


A B



C D E
Out Out 4th Disk Ctlr (10)



A



B C D

References

  1. Sun Systems Cardcage Slot Assignments and Backplane Configuration Procedures, 813-2004-16.
  2. Sun-4/200 Cardcage Slot Assignments and Backplane Configuration Procedures, 813-2037-05.

Sun-4/280

with Double-Height Backpanel
with 501-1138 or 501-1217 SCSI

Slots 7,8,9 reserved for non-Sun boards that use P2

SHUNTS BOARD SLOT POSITION
BG3 IACK 1 2 3 4 5 6 7 8 9 10 11 12
Out Out Sun 4200 CPU A A









In In 1st Memory (6)




A





In In 2nd Memory (6)

A








In In 3rd Memory (6)


A







In In 4th Memory (6)



A






Out Out GP (2)








A

In In GB









A
In
In
In
In
In
In
TAAC-1 (5)
B B B




A A A
Out Out 1st ALM-1










A
Out Out 2nd ALM-1









A
Out Out 3rd ALM-1








A

In Out 1st MCP

A B C



D E F
In Out 2nd MCP


A B



C D E
In Out 3rd MCP



A



B C D
In Out 4th MCP








A B C
In Out 1st ALM-2

A B C



D E F
In Out 2nd ALM-2


A B



C D E
In Out 3rd ALM-2



A



B C D
In Out 4th ALM-2








A B C
Out
Out
Out
Out
1st Channel
Adapter

A B
A
C
B
C



D E
D
E
Out
Out
Out
Out
2nd Channel
Adapter



A A



B C
B
C
Out
In
Out
In
1st MAPkit

A B
A
B



C D
C
D
Out
In
Out
In
2nd MAPkit








A B
A
B
Out Out SCSI (12)

A B C



D E F
In Out Color (2)

A B C



D E F
In Out CG5 w GP/GP+

A B C






In Out CG5 w GP2









A B
In Out CG9 Color









A B
In Out 1st HSI

A B C



D E F
In Out 2nd HSI


A B



C D E
Out Out Ethernet

A B C



D E F
Out Out 1st FDDI

A B C



D E F
Out Out 2nd FDDI


A B



C D E
In Out 1st IPC (3)

A B C



D E F
In Out 2nd IPC (3)


A B



C D E
In Out 3rd IPC (3)



A



B C D
In Out 4th IPC (3)








A B C
Out Out 1st Tape Ctlr (8)

A B C



D E F
Out Out 2nd Tape Ctlr (8)


A B



C D E
Out Out 1st Disk Ctlr (9)

A B C



D E F
Out Out 2nd Disk Ctlr (9)


A B



C D E
Out Out 3rd Disk Ctlr (10)



A



B C D
Out Out 4th Disk Ctlr (10)








A B C

References

  1. Sun Systems Cardcage Slot Assignments and Backplane Configuration Procedures, 813-2004-16.
  2. Cardcage Slot Assignments and Backplane Configuration Procedures for Sun 4/200 Systems with Double-Height Backpanels, 813-2071-05.


Last updated: December 2, 1996
  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.