Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

SPARCstation LX/ZX (Sun-4/30)

501-2031 501-2032 501-2233 501-2474
32MB 16MB 0MB FRU 0MB FRU

SPARCstation LX/ZX I/O Board
501-2031 / 501-2032 / 501-2233 / 501-2474

Jumper Settings

JUMPER PINS SETTING DESCRIPTION
J1801 1-2 In* 100 Ohms TE termination enabled
J1802 1-2 In* 100 Ohms TE termination enabled
J1801 2-3 In 100 Ohms TE termination disabled
J1802 2-3 In 100 Ohms TE termination disabled
* Default setting

SIMM Installation

TOTAL
MEMORY
BANK 1
U0304
BANK 2
U0301
BANK 3
U0402
BANK 1
U0303
BANK 2
U0302
BANK 3
U0401
16MB* 4MB** 4MB
4MB 4MB
24MB 4MB 4MB 4MB 4MB 4MB 4MB
32MB 16MB

16MB

40MB 4MB 16MB
4MB 16MB
48MB 4MB 4MB 16MB 4MB 4MB 16MB
64MB 16MB 16MB
16MB 16MB
72MB 4MB 16MB 16MB 4MB 16MB 16MB
96MB 16M 16MB 16MB 16MB 16MB 16MB
* 16MB SIMM 501-2059
** 4MB SIMM 501-1991

Notes

  1. The minimum operating system is Solaris 1.1c or Solaris 2.1.
  2. The PLCC Boot PROM is not a FRU and is not field replaceable.
  3. Use the MFAR value to determine the address of a failing SIMM.
    If the MFAR ends in 0, 1, 2, 3, 8, 9, A, or B, the failing SIMM is in U0304, U0301, or U0402.
    If the MFAR ends in 4, 5, 6, 7, C, D, E, or F, the failing SIMM is in U0303, U0302, or U0401.
  4. Use the OBP setenv command to change the frame buffer resolution when the VSIMM is installed:
    ok setenv output-device screen:r1280x1024x67
    ok setenv output-device screen:r1280x1024x76
    ok setenv output-device screen:r1600x1280x76
  5. Use the OBP setenv command to change the frame buffer resolution when the 16" Mid-Range Color Monitor is used:
    ok setenv output-device screen:r1152x900x66
    ok setenv output-device screen:r1024x768x77

Reference

Installing SPARCstation LX SIMMs, 801-2211.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.