Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun SPARC Enterprise T1000, RoHS:YL Server: Repair Procedures

This section provides tips (when available) for the most common repair procedures for the Sun SPARC Enterprise T1000, RoHS:YL Server. The repair procedures are provided in the following manual:

Sun SPARC Enterprise T1000 Server Service Manual(820-0019)

The following table provides tips associated with each component.

Component Tips
Disks
  • Certain Seagate disk drives may experience servo seek errors. (FAB 1022189.1).
Miscellaneous
  • Console behavior is inconsistent when a graphics device and keyboard are specified for console use. This occurs when the OpenBoot variables 'input-device' and 'output-device' are set to anything other than the default value of 'virtual-console'. (FAB 1018990.1).
Power Supply
  • A small number of Sun Fire T1000 and SPARC Enterprise T1000 systems may experience a 3.3V Standby low voltage warning and/or soft shutdown. (FCO 1019858.1).

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback