Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorEdge[tm] S1 Array: Hardware Specifications

Disks
18GB
  • Fujitsu MAN3184MC, 18.2GB - 10000 RPM, Ultra-3 SCSI
  • Seagate ST318305LC, 18.2GB - 10000 RPM, Ultra-3 SCSI
36GB
  • Seagate ST336605LC, 36.4GB - 10000 RPM, Ultra-3 SCSI
  • Fujitsu MAN3367MC, 36.4GB - 10000 RPM, Ultra-3 SCSI
  • Seagate ST336607LC, 36.4GB - 10000 RPM, Ultra-320
  • Fujitsu MAP3367NC, 36.4GB - 10000 RPM, Ultra-320
  • Hitachi DK32EJ-36NC, 36.4GB - 10000 RPM, Ultra-320
73GB
  • Seagate ST373307LC, 73.4GB - 10000 RPM, Ultra-320
  • Hitachi DK32EJ-72NC, 73.4GB - 10000 RPM, Ultra-320
  • Fujitsu MAP3735NC, 73.4GB - 10000 RPM, Ultra-320
146GB
  • Fujitsu MAP3147NC, 146GB - 10000 RPM, Ultra-320
  • Hitachi DK32EJ-14NC, 146GB - 10000 RPM, Ultra-320
Racking

Supports 19-in., 23-in., 24-in., and 600-mm rack configurations, with fixed-rail options

Standard Interfaces
LVD/SE SCSI

Two ports, 160/40 MB/s

Standard ANSI (X3.131-1994, X3.277-1996, SPI-3X3.252)

Maximum cable length 12 meters for LVD and 4 meters for SE SCSI

Direct connect to host on-board SCSI port with no host adapter

Environment
AC input voltage 100-240 VAC, 47-63 Hz
DC input voltage -48 TO -60 VDC
Input power 150 W
Input current Less than 2A at 100VAC (150W)
Less than 4A at -40 VDC (150W)
Heat output 512 BTU/hr
Temperature 1 Operating: 5° C to 40° C (41° F to 104° F)
Operating(short term): -5° C to 55° C (23° F to 131° F)
Nonoperating: -25° C to 65° C (-13° F to 149° F)
Humidity 1 Operating: 5% to 85% relative humidity, non-condensing
Operating(short term): 5% to 95% relative humidity, non-condensing
Nonoperating: 5% to 95% relative humidity, non-condensing
Altitude Operating: 0 m to 3000 m (0 ft. to 10,000 ft.)
Nonoperating: 0 m to 12,000 m (0 ft. to 40,000 ft.)
Acoustic noise Operating: 6.0 Bels
Idling: 6.0 Bels
Seismic Meets GR-63-CORE requirements for earthquake risk zone 4
Number of cords 1
1 - short term is defined as operating 96 consecurtive hours
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA-60950, EN60950, IEC950 CB Scheme with all country deviations
RFI/EMI EN55022/CISPR22 Class B, FCC CFR47 Part 15 Class B, EN61000-3-2, EN61000-3-3, EN 300 386 V1.2.1 (2000-03) - Telecom Center Only
Immunity EN55024, EN 300 386 V1.2.1 (2000-03) - Telecom Center Only
Telcordia NEBS GR-63-CORE, GR-1089-CORE, SR-3580 Level-3
Regulatory Markings CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, EK, UL/cUL, TUV-GS
Telcordia NEBS Level-3
Dimensions and Weights
Height 44 mm (1.73 in.)
Width 436 mm (17.16 in.)
Depth 450 mm (17.71 in.)
Weight 5.9 kg (13 lb.) without drives
8.8 kg (19.4 lb.) with drives

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.