Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Netra[tm] t1 100/105 Servers: Hardware Specifications

Racking

Fits into 19-, 23-, 24-in., 600 mm racks (includes mounting kit for 19-in. racks)

Processor
Number One
Architecture 360- or 440- MHz UltraSPARC-IIi, single processor, Superscalar SPARC Version 9
Cache memory

16-KB data and 16-KB instruction on chip

Secondary: 1-MB external with 360-MHz CPU, 2-MB external with 440-MHz CPU

Main Memory
Capacities

64-, 256-, and 512-MB memory cards

Total of two Sun Mezzanine memory cards supported 1.0 GB maximum (Total of four 256 MB memory cards can be installed in select units only)

Standard Interfaces
Ethernet Two ethernet/fast ethernet (10BASE-T/100BASE-T) shielded twisted-pair port (RJ-45)
PCI Single 2/3-length, 32-bit, 33-MHz PCI 2.1 compliant slot.
SCSI One 40-MB/sec, 68-pin, UltraSCSI (SCSI-3) port
Serial Two RS-232C/RS-423 serial ports (RJ-45)
Internal Mass Storage
Disks Up to two 3.5- x 1-in. disks (9 GB or 18 GB); front accessible; support for hot plug
CD-ROM

Optional 644-MB Slimline CD, 24X speed

Environment
AC input (Model 105) 100 - 240 VAC, 47 - 63 Hz, 2 A (max)
DC input (Model 100) -40 to -75 VDC, dual input, 4 A (max)
Input power 108 W
Heat output 368 BTU/hr
Temperature 1 Operating: 0° C to 40° C (32° F to 104° F)
Operating (short term): -5° C to 55° C (23° F to 131° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)

Humidity Operating: 5% to 85% relative humidity, noncondensing
Nonoperating: 10% to 95% relative humidity, noncondensing
Altitude Operating: -300 m to 3000 m (-1000 ft. to 10,000 ft.)
Nonoperating: -300 m to 12,000 m (-1000 ft. to 40,000 ft.)
ETSI ETS 300-19-2-3, Table 3.1, Climatic
Acoustic noise Operating: <60dBA
Idling: <60dBA
Seismic

GR-63-Core requirements for earthquake risk zone 4 ETSI ETS 300-19-2-3, A1 operating requirements

Number of cords 1

1 - Short term is defined as no more than 96 hours duration at extremes and at elevations less than 1800m.

Regulations
Meets or exceeds the following requirements:
Safety UL 1950/CSA C22.2 No. 950, EN 60950 (73/23/EEC), IEC 950
Emissions CFR Title 47 FCC Part 15, EN 55022 (89/336/EEC)
Immunity EN 50082-1 (89/336/EEC)
Telco environment

Telcordia: GR-63-CORE, GR-1089-CORE, TR-NWT-000295, SR 3580 NEBS Level 3

Certification

Safety: cULus Mark, TUV GS Mark, CE Mark

EMC: CE Mark (93/68/EEC), FCC authorized Class A

Dimensions and Weights
Height 44.0 mm (1.73 in.)
Width 437.2 mm (17.21 in.)
Depth 487.4 mm (19.19 in.)
Weight 9 kg (20 lbs.)
Shipping Weight (product and packing) 11.5 kg (25 lbs.)

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback