Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Netra[tm] st D130 Storage Array: Hardware Specifications

Racking

Fits into 19-in, 23-in., 24-in., and 600mm racks (includes mounting kit for 19-in. racks)

Standard Interfaces
SCSI

Two single-ended ports, 68-pin SCSI connector
Can be daisy chained via port (2 max in a chain)

Internal Mass Storage
Disk

Up to three NEBS compliant, 18.2- or 36.4-GB hot pluggable, Ultra SCSI hard drives

Environment
AC input 100 - 240 VAC, 47 - 63 Hz, <2.0 A
DC input -48 to -60 VDC, <4.0 A
Input power 150 W
Heat Output 512 BTU/hr
Temperature 1 Operating: 0° C to 40° C (32° F to 104° F)
Operating (short term): -5° C to 55° C (23° F to 131° F)
Non-operating: -25° C to 65° C (-13° F to 149° F)
Humidity 1 Operating: 5% to 90% relative humidity, noncondensing
Operating (short term): 5% to 90% relative humidity, noncondensing
Non-operating: 5% to 95% relative humidity, noncondensing
Altitude Operating: 0 m to 3000 m (0 ft. to 10,000 ft.)
Nonoperating: 0 m to 12,000 m (0 ft. to 40,000 ft.)
Acoustic noise Operating: 6.0 Bels
Idling: 6.0 Bels
Seismic Meets GR-63-CORE requirements for earthquake risk zone 4
Number of cords 1
1 - Short term is defined as 96 consecutive hours of operating.
If you plan to operate the controller module at altitudes between 1000m and 3000m (3280 ft. and 9850 ft.), you must lower the environmental temperature 3.3° C (1.7° F) for every 1000m (3280 ft.) above sea level.
Regulations
Meets or exceeds the following requirements:
Safety UL 1950, CSA C22.2-No. 950, EN 60950 (73/23/EEC), IEC 950
Emissions CFR Title 47 FCC Part 15, EN 55022 (89/336/EEC)
Immunity EMC Directive (89/336/EEC), EN50082-1
Telco environment

Telcordia GR-63-CORE, NEBS GR-1089-CORE, TR-NWT-000295

Certification Telcordia: SR 3580 NEBS Level 3 certified
Safety: cULus Mark, TUV GS Mark, CE Mark
EMC: CE Mark (93/68/EEC), FCC authorized Class A
Dimensions and Weights
Height 4.4 cm (1.73 in.)
Width 43.6 cm (17.2 in.)
Depth 47.2 cm (18.6 in.)
Weight (without drives) 5.9 kg (13 lb.)
(with 3 drives) 8.16 kg (18 lb.)
Shipping Weight 9.5 kg (20 lb.)

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback