Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Netra[tm] X1 Server: Hardware Specifications

Racking
Standard telco racks: 19 in.
Processor
Number One
Architecture 400 MHz or 500 MHz UltraSPARC IIe
Cache 16 KB data and 16 KB instruction on-chip; Secondary: 256 on-chip
Main Memory
Capacities

128- or 256-MB DIMMs
512-MB DIMMs (500 MHz models)

1 GB maximum (400 MHz models)
2 GB maximum (500 MHz models)

Standard Interfaces
Ethernet Two ethernet/fast ethernet (10BASE-T/100BASE-T) shielded twisted-pair (STP) connector (RJ-45)
Serial Two RS-232C/RS-423 serial ports (RJ45); port A is used for LOM
System Configuration Reader and Card

Rear-accessible for transfer of system configuration information, including hostid

USB Two standard Universal Serial Bus (USB) Type A ports
Internal Mass Storage
Disk

Up to two 5400 RPM, 20-GB IDE disks (400 MHz models)
Up to two 7200 RPM, 40.8-GB ATA disks (500 MHz models)

Environment
AC input 90 - 264 VAC, 47 - 63 Hz, 1.3 A(max)
Input power 81 W(max)
Heat output 148 BTU/hr (nominal) to 280 BTU/hr (max)
Temperature Operating: 5° C to 40° C (41° F to 104° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
Humidity Operating: 5% to 85% relative humidity, noncondensing
Nonoperating: 10% to 95% relative humidity, noncondensing
Altitude Operating: -300 m to 3000 m (-1000 to 10,000 ft.)
Nonoperating: -300 m to 12,000 m (-1000 to 40,000 ft.)
Acoustic noise Operating: 6.3 bels
Idling: 6.0 bels
Number of cords 1
Regulations
Meets or exceeds the following requirements:
Safety UL 1950, EN 60950
Emissions EN 55022 Class A, FCC Class A
Immunity EN 55025
Dimensions and Weights
Height 43.6 mm (1.7 in)
Width 436.7 mm (17.2 in)
Depth 330.0mm (13.0 in)
Weight 6.0 kg (13.2 lb)
Shipping Weight 10.0 kg (22.0 lb)

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback