Racking |
Fits 19-inch, 23-inch, 24-inch, 600 mm racks (includes mounting kit for
19-inch racks)
Racking in StorEdge 72" rack as available
|
PCI Connectivity |
Number of Slots |
Four 64-bit, 33-MHz full-length 5V or universal voltage slots |
Host Interface Card |
Half-size 32-bit, 33-MHz card, universal voltage |
PCI Bus |
32-bit, 33-MHz bus (to host); 64-bit, 33-MHz bus (internal) |
PCI Cards |
Supports all PCI-compliant cards |
Maximum Number of Sun Expanders Per Server |
Netra T1: One
Netra t 1120/1125: Up to two (directly connected to host)
Netra t 1400/1405: Up to two (directly connected to host)
|
Environment |
AC input |
100 - 240 VAC, 47 - 63 Hz, 2.5 A |
DC input |
-48 to -60 VDC, 5.5 A |
Input power |
189 W |
Heat output |
646 BTU/hr |
Temperature |
Operating: 5° C to 40° C (41° F to 104° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
|
Humidity |
Operating: 5% to 80% relative humidity, noncondensing
Nonoperating: 90% relative humidity, noncondensing |
Acoustic noise |
Operating: 6.4 Bel
Idling: 6.4 Bel |
Seismic |
GR-63-CORE requirements for earthquake risk zone 4 |
Number of cords |
1 |
Regulations
Meets or exceeds the following
requirements: |
Safety |
UL 1950/CSA C22.2 No.950, EN 60950 (73/23/EEC), IEC 950 (with all country
deviations) |
Emissions |
CFR Title 47 FCC Part 15, EN 55022 (89/336/EEC), ICES-003 |
Immunity |
EN 55024:1998; EN 61000-4-2,-3,-4,-5,-6,-11; EN 61000-3-2,-3 |
Telco Environment |
NEBS Level 3 Certified, Telcordia: GR-63-CORE, GR-1089-CORE, TR-NWT-00295 |
Certification |
Safety: cULus, GOST, TUV GS, CE, CB Scheme
EMC: CE (89/336/EEC, 93/68/EEC), GOST, VCCI, BSMI, IC, FCC authorized
Class A
|
Dimensions
and Weights |
Height |
43.9 mm (1.7 in) |
Width |
436.7 mm (17.2 in) |
Depth |
474.9 mm (18.7 in) |
Weight (fully loaded) |
6.8 kg (15.0 lb) |
Weight (without PCI cards) |
7.9 kg (17.4 lb) |