Processor
|
Number |
Two to four |
Architecture |
UltraSPARC® IIIi (1.28 or 1.593 GHz) |
Cache memory |
64 KB data, 32 KB instruction and 1 MB integrated L2 |
Main Memory
|
Capacities |
4 DIMM slots per processor
Registered DDR-1 SDRAM (PC2100) 128-bit plus ECC databus
System configurations from 4 GB to 32 GB
|
Standard/Integrated Interfaces
|
Network |
Two 10/100/1000Base-T Ethernet ports
|
Network Management |
One 10Base-T Ethernet port
|
Serial |
One TIA/EIA-232-F asynchronous (DB9) Port
|
Serial Management |
One TIA/EIA-232-F (RJ45) Port
|
SCSI |
One Ultra320 SCSI multimode (SE/LVD) |
USB |
Four OHCI 1.0-Compliant Interfaces, supporting dual speeds of 12 and 1.5
Mbits/sec each
|
Expansion bus |
Six internal PCI 2.2 compliant expansion slots:
- Three full-length 64-bit 33/66 MHz 3.3V
- Three full-length 64-bit 33 MHz 5V
|
System Configuration Card and reader |
(Removable) Front accessible for transfer of system configuration
information, including host ID, MAC address and NVRAM |
Alarms |
Four fail-safe, dry contact alarms (critical, major, minor and user) |
Internal Mass Storage
|
Disks |
Up to four hot plug front-accessible Ultra320 SCSI 73GB or 146GB 15K-RPM Disks |
DVD-ROM |
Optional Slimline ATAPI DVD-ROM or DVD-RW |
Power Supplies
|
Minimum of two power supplies (DC or AC) required.
The below are based on two power supplies.
|
Maximum Input Power |
1040W |
Maximum Output Power (DC) |
800W |
Maximum Power Consumption (typ) |
660W |
Maximum Input Current (DC) |
23A |
BTU |
2252BTU/hour @ 660W maximum power consumption |
Redundancy |
2+2, hot-swap with separate power cords |
Environment
|
DC power |
-40V to -75V DC (range) - up to 4 power supplies
-48V or -60V DC (nominal) |
AC power |
90-264Vac, 47-63Hz, < 6.5 Amps RMS at 100Vac |
Operating Temperature |
5°C to 40°C (41°F to 104°)
Short term:* -5°C to 55°C (23°F to 131°)
* No more than 96 hours, altitudes up to 1800m (5905.44 ft)
|
Nonoperating Temperature |
-40°C to 70°C (-40°F to 158°)
|
Operating Humidity |
5% to 85% relative humidity, noncondensing
Short term:* 5% to 90% relative humidity, noncondensing
but not to exceed 0.024 kg water/1 kg dry air
(0.053 lb water/2.205 lb dry air)
* No more than 96 hours, altitudes up to 1800m (5905.44 ft)
|
Nonoperating Humidity |
Up to 93% relative humidity, noncondensing,
38°C (100.4°F) max wet bulb
|
Altitude |
Operating: Up to 3000m (9842.4 ft)
Nonoperating: Up to 12000m (39369.6 ft)
|
Acoustic noise |
Declared Noise emissions in accordance with ISO 9296:
Operating: 7.0 Bels (LWAd(1B=10dB))
Idling: 7.0 Bels (LWAd(1B=10dB))
|
ETSI |
EN 300 019-2-1,2,3, Table 3.1 & 3.1 E
Except -5°C cold start
Except condensing humidity
Except rain
|
Seismic |
GR-63-CORE requirements for earthquake zone 4
|
Regulations
Meets or exceeds the following requirements:
|
Safety |
IEC60950, UL/CSA60590, EN60950
|
RFI/EMI |
FCC Class A, Part 15 47 CFR, EN55022, CISPR 22, EN 300-386:2001
V1.3.1, ICES-003
|
Immunity |
EN55024 |
Certifications |
Safety: cULus Mark, TUV GS Mark, CE Mark, CCC, GOST R
EMC: CE Mark (93/68/EEC), FCC authorized Class A, VCCI, BSMI,
C-Tick, MIC
Telecommunication: Telcordia GR-63 CORE, GR-1089-CORE,
SR 3580 NEBS Level 3
|
Dimensions and Weights
|
Height |
222 mm (8.75 in.) |
Width |
440 mm (17.3 in.) including bezel |
Depth |
476 mm (18.75 in.) front bezel tangent to rear I/O panel
495 mm (19.5 in.) overall maximum depth |
Weight |
36 kg (79.4 lb.) - Not including PCI cards and rack unit
37 kg (81.6 lb.) - Fully configured with PCI cards and rack unit |
Enclosure
|
Fits into a standard 19-inch wide rack.
Rack kit included: 19-inch 2- and 4-post.
Additional rack kits available: 23-inch 2-post, 600mm × 600mm,
and 19-inch 4-post slide adjustable up to 800mm.
|
Supports Sun Rack 900 and 1000. Must use X8100A rack kit.
|