Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Netra[tm] 440 Server: Hardware Specifications

Processor
Number Two to four
Architecture UltraSPARC® IIIi (1.28 or 1.593 GHz)
Cache memory 64 KB data, 32 KB instruction and 1 MB integrated L2
Main Memory
Capacities 4 DIMM slots per processor
Registered DDR-1 SDRAM (PC2100) 128-bit plus ECC databus
System configurations from 4 GB to 32 GB
Standard/Integrated Interfaces
Network Two 10/100/1000Base-T Ethernet ports
Network Management One 10Base-T Ethernet port
Serial One TIA/EIA-232-F asynchronous (DB9) Port
Serial Management One TIA/EIA-232-F (RJ45) Port
SCSI One Ultra320 SCSI multimode (SE/LVD)
USB Four OHCI 1.0-Compliant Interfaces, supporting dual speeds of 12 and 1.5 Mbits/sec each
Expansion bus Six internal PCI 2.2 compliant expansion slots:
  • Three full-length 64-bit 33/66 MHz 3.3V
  • Three full-length 64-bit 33 MHz 5V
System Configuration Card and reader (Removable) Front accessible for transfer of system configuration information, including host ID, MAC address and NVRAM
Alarms Four fail-safe, dry contact alarms (critical, major, minor and user)
Internal Mass Storage
Disks Up to four hot plug front-accessible Ultra320 SCSI 73GB or 146GB 15K-RPM Disks
DVD-ROM Optional Slimline ATAPI DVD-ROM or DVD-RW
Power Supplies
Minimum of two power supplies (DC or AC) required. The below are based on two power supplies.
Maximum Input Power 1040W
Maximum Output Power (DC) 800W
Maximum Power Consumption (typ) 660W
Maximum Input Current (DC) 23A
BTU 2252BTU/hour @ 660W maximum power consumption
Redundancy 2+2, hot-swap with separate power cords
Environment
DC power -40V to -75V DC (range) - up to 4 power supplies
-48V or -60V DC (nominal)
AC power 90-264Vac, 47-63Hz, < 6.5 Amps RMS at 100Vac
Operating Temperature 5°C to 40°C (41°F to 104°)

Short term:* -5°C to 55°C (23°F to 131°)
* No more than 96 hours, altitudes up to 1800m (5905.44 ft)
Nonoperating Temperature -40°C to 70°C (-40°F to 158°)
Operating Humidity 5% to 85% relative humidity, noncondensing

Short term:* 5% to 90% relative humidity, noncondensing
but not to exceed 0.024 kg water/1 kg dry air (0.053 lb water/2.205 lb dry air)
* No more than 96 hours, altitudes up to 1800m (5905.44 ft)
Nonoperating Humidity Up to 93% relative humidity, noncondensing, 38°C (100.4°F) max wet bulb
Altitude Operating: Up to 3000m (9842.4 ft)
Nonoperating: Up to 12000m (39369.6 ft)
Acoustic noise Declared Noise emissions in accordance with ISO 9296:
Operating: 7.0 Bels (LWAd(1B=10dB))
Idling: 7.0 Bels (LWAd(1B=10dB))
ETSI EN 300 019-2-1,2,3, Table 3.1 & 3.1 E
Except -5°C cold start
Except condensing humidity
Except rain
Seismic GR-63-CORE requirements for earthquake zone 4
Regulations
Meets or exceeds the following requirements:
Safety IEC60950, UL/CSA60590, EN60950
RFI/EMI FCC Class A, Part 15 47 CFR, EN55022, CISPR 22, EN 300-386:2001 V1.3.1, ICES-003
Immunity EN55024
Certifications Safety: cULus Mark, TUV GS Mark, CE Mark, CCC, GOST R
EMC: CE Mark (93/68/EEC), FCC authorized Class A, VCCI, BSMI, C-Tick, MIC
Telecommunication: Telcordia GR-63 CORE, GR-1089-CORE, SR 3580 NEBS Level 3
Dimensions and Weights
Height 222 mm (8.75 in.)
Width 440 mm (17.3 in.) including bezel
Depth 476 mm (18.75 in.) front bezel tangent to rear I/O panel
495 mm (19.5 in.) overall maximum depth
Weight 36 kg (79.4 lb.) - Not including PCI cards and rack unit
37 kg (81.6 lb.) - Fully configured with PCI cards and rack unit
Enclosure
Fits into a standard 19-inch wide rack.
Rack kit included: 19-inch 2- and 4-post.
Additional rack kits available: 23-inch 2-post, 600mm × 600mm, and 19-inch 4-post slide adjustable up to 800mm.
Supports Sun Rack 900 and 1000. Must use X8100A rack kit.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback