Racking |
Fits into a standard 19-inch wide rack. Rack kit included 19-inch 4 post.
Additional rack kits available 19-inch 2 post, 23-inch 2 post, 600mm x
600mm, and 19-inch 4 post slide adjustable up to 800 mm
|
Processor |
Number |
One to two |
Architecture |
1.28GHz or 1.503GHz UltraSPARC IIIi, 64 bit, 4-way Superscalar SPARC V9
|
Cache memory |
64 KB data, 32KB instruction and 1 MB integrated L2
|
Main
Memory |
Capacities |
- 4 DIMM slots per processor, registered DDR-1 SDRAM (PC2100) 128 bit
+ ECC databus
- System configuration from 1GB to 8GB
|
Standard
Interfaces |
Alarms |
Four fail-safe, dry contact alarms (critical, major, minor and user) with
external reset input via DB15 pin connector |
Ethernet |
- Four 10/100/1000 BaseT Ethernet
- One 10 BaseT Ethernet (Network Management)
|
PCI |
Three internal PCI 2.2 compliant expansion slots:
- One 64 bit 33/66 MHz 3.3V full-length
- Two 64 bit 33 MHz 5V half-length
|
SCSI |
One Ultra160 SCSI multimode (SE/LVD) |
Serial |
- One TIA/EIA-232-F asynchronous (DB9) Port
- One TIA/EIA-232-F (RJ45) Port (Serial Management)
|
System Configuration Reader and Card |
Front accessible for transfer of system configuration information, including
host ID, MAC address, NVRAM
|
USB |
Two OHCI-1.0 Compliant Interfaces, supporting dual speeds of 12 and 1.5
Mbits/sec each |
Internal
Mass Storage |
Disks |
Up to two hot-swap Ultra-320 SCSI 73GB or 146GB 15Krpm disks |
DVD-ROM |
- Optional slim-line ATAPI DVD-ROM
- Optional slim-line DVD-RW
|
Environment |
Power Supplies
(AC Version) |
1+1 with independent power cords
Max. input power: 550 W
Max. output power: 400 W
Max. power consumption: 353 W
Input current: 6.1A (at 90 VAC)
|
Power Supplies
(DC Version) |
1+1 with independent power cords
Max. input power: 570 W
Max. output power: 400 W
Max. power consumption: 364 W
Input current: 15A Max
|
AC power |
90-264 V AC (47-63 Hz) |
DC Power |
-40V to -75V DC (range), single or dual power sources
-48V or -60V DC (nominal) |
Heat output |
1,241 BTU/hr
|
Temperature |
Operating: (AC) 0° C to 40° C (32° F to 104° F)
Operating: (DC) -5°C to 45°C (23°F to 113°F); short
term -5°C to 55°C (23°F to 131°F)
Nonoperating: -40°C to 70°C (-40°F to 158°F) |
Humidity |
Operating: (AC) 90% relative humidity, noncondensing, 40° C
max wet bulb
Operating: (DC) 5% to 93% relative humidity, noncondensing
Nonoperating: up to 93% relative humidity, noncondensing |
Altitude |
Operating: Up to 3000m
Nonoperating: Up to 12000m |
Acoustic noise |
Declared Noise emissions in accordance with ISO 9296:
Operating: 7.0 B [LWAd(1B=10dB)]
Idling: 7.0 B [LWAd(1B=10dB)]
|
ETSI |
EN 300-019-2-1,2,3, Table 3.1 & Table 3.1E |
Seismic |
GR-63-CORE requirements for earthquake zone 4 |
Regulations
Meets or exceeds the following requirements: |
Safety |
IEC60950, UL/CSA60950, EN60950 |
RFI/EMI |
FCC Class A, part 15 47 CFR, EN55022, CISPR 22, EN 300-386:2001 V1.3.1,
ICES-003 |
Certification |
Safety: cULus Mark, TUV GS Mark, CE Mark, CCC, GOST R
EMC: CE Mark (93/68/EEC), FCC authorized Class A, VCCI, BSMI, C-Tick,
MIC Telecommunication: Telcordia GR-63 CORE, GR-1089-CORE, SR 3580 NEBS
Level3 |
Dimensions
and Weights |
Height |
87.4 mm (3.44-inch) - 2RU |
Width |
425mm (16.73-inch) not including bezel
442mm (17.4-inch) including bezel |
Depth |
483mm (19-inch) to rear connectors
483mm (19-inch) to rear connectors |
Weight |
16.3kg (36 lbs); 18.6kg (41 lbs) fully configured with rackmount kit |