Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorEdge[tm] N8400/N8600 Filer: Hardware Specifications

Feature
N8400 - Enterprise 420R and T3 arrays mounted in a rack N8600 - Enterprise 4500 with T3 arrays mounted in racks
Supported naming environments NIS, NIS+, DNS, LDAP NIS, NIS+, DNS, LDAP
Network protocol support NFS versions 2 and 3 over UDP or TCP, CIFS NFS versions 2 and 3 over UDP or TCP, CIFS
ECC memory 4096MB 8192MB
Nonvolatile memory 256MB per array 256MB per array
NIC expansion capacity
3.3v, 33/66 MHz, 32/64 bit PC slot
5v, 33 MHz, 32/64 bit PC slot
3 SBUS slots
Optional NIC connectivity Single 10/100-BaseT Ethernet, Gigabit Ethernet, Quad Fast Ethernet Single 10/100-BaseT Ethernet, Gigabit Ethernet, Quad Fast Ethernet
Disk Drives
73GB FC-AL 73GB FC-AL
RAID storage capacity Minimum: 18 X 73-GB FC-AL drives
Maximum: 72 X 73-GB FC-AL drives
Minimum: 18 X 73-GB FC-AL drives
Maximum: 72 X 73-GB FC-AL drives
Maximum usable capacity 4TB 10TB
Minimum file systems/volumes
Maximum file systems/volumes
One per array
No limit
One per array
No limit
RAID level Hardware RAID 5 Hardware RAID 5
Maximum RAID group size 7 data/1 pa ity/1 hot spare 7 data/1 pa ity/1 hot spare
 
Full-duplex 10/100-BaseT Ethernet Standard Standard
Diagnostic LEDs Standard Standard
Redundant hot-plug system cooling fans Standard Standard
Redundant hot-plug power supplies (N+1) Standard Standard
Hot-spare Standard Standard
Dual power cords Standard Standard
Rack-mount kit Optional Optional
Environment
N8400 Filer Controller (E420R) N8600 Filer Controller (E4500) N8400/N8600 Filer Array (T3)
AC input 100 - 240 VAC, 47 - 63 Hz, 0.4 K VA, 6.25 A 100 - 240 VAC, 47 - 63 Hz, 12 A 100 - 240 VAC, 47-63 Hz, 5 A
Temperature Operating: 5° C to 40° C (41° F to 104° F)
Nonoperating: -40° C to 60° C (-40° F to 140° F)
Operating: 5° C to 40° C (41° F to 104° F)
Nonoperating: -40° C to 60° C (-40° F to 140° F)
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -20° C to 60° C (-4° F to 140° F)
Humidity Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 95% relative humidity, noncondensing
Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing
Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing
Altitude Operating: 3000 m (10, 000 ft.)
Nonoperating: 12,000 m (40, 000 ft.)
Operating: 3000 m (10, 000 ft.)
Nonoperating: 12,000 m (40, 000 ft.)
Operating: -300 m to 3000 m (-1000 ft. to 10, 000 ft.)
Nonoperating: -300 m to 12,000 m (-1000 ft. to 40, 000 ft.)
Vibration Operating: 0.2 G peak, 5-500 Hz (swept sine); 0.0002 G2/Hz, 5-500 Hz (random)
Nonoperating: N/A
Operating: N/A
Nonoperating: N/A
Operating: 0.2 G peak, 5-500 Hz (swept sine); 0.0002 G2/Hz, 5-500 Hz (random); 0.25 G, 5-500 Hz (any axis)
Nonoperating: 1.0 G, 5-500 Hz (any axis)
Shock Operating: 4 G peak, 11 mS half-sine pulse
Nonoperating: N/A
Operating: N/A
Nonoperating: N/A
Operating: 4 G peak, 11 mS half-sine pulse
Nonoperating: 10 G peak, 11 mS half-sine pulse
Regulations
Meets or exceeds the following requirements:
N8400 Filer Controller (E420R) N8600 Filer Controller (E4500) N8400/N8600 Filer Array (T3)
Safety UL 1950, CSA C 22.2 No. 950, TUV EN 60950, CB Scheme to IEC 60950 with full deviations UL 1950, CSA C22.2 No. 950, TUV EN 60950, CB Scheme (Nordic Deviation) UL 1950, CSA C22.2 No. 950, TUV EN 60950, CB Scheme to IEC 60950 with full deviations
RFI/EMI FCC Class A, DOC Class A, EN 55022/CISPR 22 Class A, VCCI Class A FCC Class A, DOC Class A, EN 55022/CISPR 22 Class A, VCCI Class A FCC Class A, DOC Class A, EN 55022/CISPR 22 Class A, VCCI Class A
Immunity CISPR 24 (EN 55024) CISPR 24 (EN 55024) CISPR 24 (EN 55024)
Dimensions and Weights
N8400 Filer Controller (E420R) N8600 Filer Controller (E4500) N8400/N8600 Filer Array (T3)
Height 17.8 cm (7.0 in.) 34.0 cm (13.5 in.) 14.0 cm (5.5 in.) (3.5U)
Width 44.9 cm (17.2 in.) 50.0 cm (19.7 in.) 44.5 cm (17.5 in.)
Depth 69.6 cm (27.2 in.) 56.0 cm (22.0 in.) 47.0 cm (18.5 in.)
Weight 29.5 kg (65.0 lb.) (Shipping Weight) 68 kg (150.0 lb. approximate) 30.2 kg (67.0 lb. maximum, with half-height drives)

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback