18GB Fujitsu MAG3182LC 18GB 10000 RPM 1" Height Disk Drive
Fujitsu MAJ3182MC 18GB 10000 RPM 1" Height Disk Drive
Seagate ST318203LC 18GB 10000 RPM 1" Height Disk Drive
Seagate ST318404LC 18GB 10000 RPM 1" Height Disk Drive
Base units come in 200GB and 400GB models, upgradeable in 200GB increments to a total of 800GB.
Two 450MHz UltraSPARC[tm] II Modules, with 4MB cache.
2GB, 16 slots, each populated with 128MB, 60ns DIMMs, 576 bits wide.
Controller Array
AC input 100 - 240 VAC, 47 - 63 Hz, 6.25 A, 0.4 KVA 100 - 240 VAC, 50 - 60 Hz, 24 A
Heat Output 2080 BTU/hr 1092 BTU/hr
Temperature Operating: 5° C to 40° C (41° F to 104° F)
Nonoperating: -40° C to 60° C (-40° F to 140° F)
Operating: 5° C to 40° C (41° F to 104° F)
Nonoperating: -20° C to 60° C (-4° F to 140° F)
Humidity Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 95% relative humidity, noncondensing
Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 93% relative humidity, noncondensing
Acoustic noise n/a 63.7 dBA
Controller Array
Safety UL 1950, CSA C22.2-No. 950, TUV-EN 60950, CB Scheme to IEC 950 with full deviations UL 1950, CSA C22.2-No. 950, TUV-EN 60950
RFI/EMI FCC Class A, DOC Class B, VCCI Class A, EN 55022 Class B VCCI Class 2, FCC Part 15 Class B, EN 55022 Class B/CISPR 22 Class B
Immunity EN 50082-1 EN 50082-1, EMC Directive (89/336/EEC) IEC-1000-2, IEC-1000-3, IEC-1000-4, IEC-1000-5
X-ray DHHS 21 Subchapter J; PTB German X-ray Decree n/a
Controller Array
Height 17.8 cm (7.0 in.) 17.8 cm (7.0 in.)
Width 44.9 cm (17.7 in.) 53.3 cm (21.0 in.)
Depth 69.6 cm (27.2 in.) 44.7 cm (17.6 in.)
Weight 29.5 kg (65.0 lb.) 28.4 kg (62.5 lb.)