Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorEdge[tm] L25/L100 Tape Library: Hardware Specifications

DLT 8000 DLT 8000 High Voltage Differential SCSI Tape Drive
LTO LTO High Voltage Differential SCSI Tape Drive
LTO LVD LTO1 Low Voltage Differential SCSI Tape Drive
LTO2 Low Voltage Differential SCSI Tape Drive
LTO3 Low Voltage Differential SCSI Tape Drive
SDLT 220 SDLT 220 High Voltage Differential SCSI Tape Drive
SDLT 320 SDLT 320 Low Voltage Differential SCSI Tape Drive
SDLT 600 SDLT 600 Low Voltage Differential SCSI Tape Drive
AC Voltage Range 88 to 264 VAC
Frequency 47 to 63 Hz
Power Consumption L25: 200W average, 250W maximum
L100: 320W average, 400W maximum
Heat Dissipation L25: 682 BTU/hr
L100: 1092 BTU/hr
Power Cable US NEMA 5-15P male / IEC 320 C13 female
Temperature & Humidity Operating:
L25: 10° C to 40° C (50°F to 104° F), 20% to 80% noncondensing
L100: 10° C to 40° C (50° F to 104° F), 20% to 80% noncondensing
Nonoperating:
L25: -40° C to 60° C (-40° F to 140° F), 5% to 90% noncondensing
L100:
-40° C to 60° C (-40° F to 140° F), 10% to 95% noncondensing
Altitude Operating:
L25: -300 to 3000 M (-1000 to 10000 ft)
L100: 0 to 2439 M (0 to 8000 ft)
Nonoperating:
L25: -300 to 11000 M (-1000 to 36000 ft)
L100: 0 to 11000 M (0 to 36000 ft)
Noise (in accordance with ISO 9296) 7.5 Bels operating
7.0 Bels idle
Shock 4.0 g, 11 msec. Half-sine, applied in all six directions
Vibration 0.21gRMS (random)
0.25 g (5-500-5 Hz, 5 sweeps), operating axis (bottom)
Height L25:176 mm (6.9 in)
L100: 599 mm (23.6 in)
Width L25: 482 mm (19 in)
L100: 482 mm (19 in)
Depth L25: 726 mm (28.6 in)
L100: 726 mm (28.6 in)
Weight (without drives) L25: 34 kg (75 lb)
L100: 95.3 kg (210 lb)
Safety UL-1950, CSA C22.2 950, EN 60950
RFI/EMI FCC CFR 47-15J (Level A), EN55022 (CISPR 22) Level A, EN 55024 (CISPR 24), VCCI
LTO LTO1 LVD LTO2 LVD LTO3 LVD DLT 8000 SDLT 220 SDLT 320 SDLT 600
Number of Tape Drives L25: 1 or 2
L100: 1 to 6
L25: 1 or 2
L100: 1 to 6
L25: 1 or 2
L100: 1 to 6
L25: 1 or 2
L100: 1 to 6
L25: 1 or 2
L100: 1 to 6
L25: 1 or 2
L100: 1 to 6
L25: 1 or 2
L100: 1 to 6
L25: 1 or 2
L100: 1 to 6
Number of Cartridges L25: up to 25
L100 (5 drives): up to 100
L100 (6 drives): up to 87
L25: up to 25
L100 (5 drives): up to 100
L100 (6 drives): up to 87
L25: up to 25
L100 (5 drives): up to 100
L100 (6 drives): up to 87
L25: up to 25
L100 (5 drives): up to 100
L100 (6 drives): up to 87
L25: up to 21
L100 (5 drives): up to 84
L100 (6 drives): up to 73
L25: up to 21
L100 (5 drives): up to 84
L100 (6 drives): up to 73
L25: Up to 21
L100 (5 drives): up to 84
L100 (6 drives): up to 73
L25: Up to 21
L100 (5 drives): up to 84
L100 (6 drives): up to 73
Cartridge Capacity 100 GB 100 GB 200 GB1 400 GB2 40 GB 110 GB 160 GB 300 GB
Maximum Library Capacity (native) L25: 2.5 TB
L100 (5 drives): 10 TB
L100 (6 drives): 8.7 TB
L25: 2.5 TB
L100 (5 drives): 10 TB
L100 (6 drives): 8.7 TB
L25: 5 TB
L100 (5 drives): 20 TB
L100 (6 drives): 17.4 TB
L25: 10 TB
L100 (5 drives): 40 TB
L100 (6 drives): 34.8 TB
L25: 840 GB
L100 (5 drives): 3.36 TB
L100 (6 drives): 2.9 TB
L25: 2.31 TB
L100 (5 drives): 9.24 TB
L100 (6 drives): 8.03 TB
L25: 3.36 TB
L100 (5 drives): 13.44 TB
L100 (6 drives): 11.68 TB
L25: 6.3 TB
L100 (5 drives): 25.2 TB
L100 (6 drives): 21.9 TB
Drive Sustained Transfer Rate 15 MB/sec 15 MB/sec 30 MB/sec 40 MB/sec 6 MB/sec 11 MB/sec 16 MB/sec 36 MB/sec
Maximum Transfer Rate (library) L25: 30 MB/sec
L100: 90 MB/sec
L25: 30 MB/sec
L100: 90 MB/sec
L25: 60 MB/sec
L100: 180 MB/sec
L25: 80 MB/sec
L100: 240 MB/sec
L25: 12 MB/sec
L100: 36 MB/sec
L25: 22 MB/sec
L100: 66 MB/sec
L25: 32 MB/sec
L100: 96 MB/sec
L25: 72 MB/sec
L100: 216 MB/sec
1 When using LTO2 200GB media. If using LTO1 (100GB) media in LTO2 drive, you get 33% better Read/Write performance over using the same data cartridge in an LTO1 drive.
2 Backward read/write compatible with LTO2; backward read compatible with LTO1.
Allow at least 12.7 cm (5 in) of space behind the library to allow proper ventilation.

 


  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback