DLT 8000 |
DLT 8000 High Voltage Differential SCSI
Tape Drive |
LTO |
LTO High Voltage Differential SCSI Tape
Drive |
LTO LVD |
LTO1 Low Voltage Differential SCSI Tape Drive
LTO2 Low Voltage Differential SCSI Tape Drive
LTO3 Low Voltage Differential SCSI Tape Drive |
SDLT 220 |
SDLT 220 High Voltage Differential SCSI
Tape Drive |
SDLT 320 |
SDLT 320 Low Voltage Differential SCSI Tape
Drive |
SDLT 600 |
SDLT 600 Low Voltage Differential SCSI Tape
Drive |
|
AC Voltage Range |
88 to 264 VAC |
Frequency |
47 to 63 Hz |
Power Consumption |
L25: 200W average, 250W maximum
L100: 320W average, 400W maximum |
Heat Dissipation |
L25: 682 BTU/hr
L100: 1092 BTU/hr |
Power Cable |
US NEMA 5-15P male / IEC 320 C13 female
|
Temperature & Humidity |
Operating:
L25: 10° C to 40° C (50°F to 104° F), 20% to
80% noncondensing
L100: 10° C to 40° C (50° F to 104° F), 20% to
80% noncondensing
Nonoperating:
L25: -40° C to 60° C (-40° F to 140° F), 5% to
90% noncondensing
L100: -40° C to 60° C (-40° F to 140° F), 10% to
95% noncondensing |
Altitude |
Operating:
L25: -300 to 3000 M (-1000 to 10000 ft)
L100: 0 to 2439 M (0 to 8000 ft)
Nonoperating:
L25: -300 to 11000 M (-1000 to 36000 ft)
L100: 0 to 11000 M (0 to 36000 ft) |
Noise (in accordance with ISO 9296) |
7.5 Bels operating
7.0 Bels idle |
Shock |
4.0 g, 11 msec. Half-sine, applied in all
six directions |
Vibration |
0.21gRMS (random)
0.25 g (5-500-5 Hz, 5 sweeps), operating axis (bottom) |
|
Height |
L25:176 mm (6.9 in)
L100: 599 mm (23.6 in) |
Width |
L25: 482 mm (19 in)
L100: 482 mm (19 in) |
Depth |
L25: 726 mm (28.6 in)
L100: 726 mm (28.6 in) |
Weight (without drives) |
L25: 34 kg (75 lb)
L100: 95.3 kg (210 lb) |
Regulations
Meets or exceeds the following requirements:
|
Safety |
UL-1950, CSA C22.2 950, EN 60950 |
RFI/EMI |
FCC CFR 47-15J (Level A), EN55022 (CISPR
22) Level A, EN 55024 (CISPR 24), VCCI |
|
LTO |
LTO1
LVD |
LTO2
LVD |
LTO3 LVD |
DLT 8000 |
SDLT 220 |
SDLT 320 |
SDLT 600 |
Number of Tape Drives |
L25: 1 or 2
L100: 1 to 6 |
L25: 1 or 2
L100: 1 to 6 |
L25: 1 or 2
L100: 1 to 6 |
L25: 1 or 2
L100: 1 to 6 |
L25: 1 or 2
L100: 1 to 6 |
L25: 1 or 2
L100: 1 to 6 |
L25: 1 or 2
L100: 1 to 6 |
L25: 1 or 2
L100: 1 to 6 |
Number of Cartridges |
L25: up to 25
L100 (5 drives): up to 100
L100 (6 drives): up to 87 |
L25: up to 25
L100 (5 drives): up to 100
L100 (6 drives): up to 87 |
L25: up to 25
L100 (5 drives): up to 100
L100 (6 drives): up to 87 |
L25: up to 25
L100 (5 drives): up to 100
L100 (6 drives): up to 87 |
L25: up to 21
L100 (5 drives): up to 84
L100 (6 drives): up to 73 |
L25: up to 21
L100 (5 drives): up to 84
L100 (6 drives): up to 73 |
L25: Up to 21
L100 (5 drives): up to 84
L100 (6 drives): up to 73 |
L25: Up to 21
L100 (5 drives): up to 84
L100 (6 drives): up to 73 |
Cartridge Capacity |
100 GB |
100 GB |
200 GB1 |
400 GB2 |
40 GB |
110 GB |
160 GB |
300 GB |
Maximum Library Capacity (native) |
L25: 2.5 TB
L100 (5 drives): 10 TB
L100 (6 drives): 8.7 TB |
L25: 2.5 TB
L100 (5 drives): 10 TB
L100 (6 drives): 8.7 TB |
L25: 5 TB
L100 (5 drives): 20 TB
L100 (6 drives): 17.4 TB |
L25: 10 TB
L100 (5 drives): 40 TB
L100 (6 drives): 34.8 TB |
L25: 840 GB
L100 (5 drives): 3.36 TB
L100 (6 drives): 2.9 TB |
L25: 2.31 TB
L100 (5 drives): 9.24 TB
L100 (6 drives): 8.03 TB |
L25: 3.36 TB
L100 (5 drives): 13.44 TB
L100 (6 drives): 11.68 TB |
L25: 6.3 TB
L100 (5 drives): 25.2 TB
L100 (6 drives): 21.9 TB |
Drive Sustained Transfer Rate |
15 MB/sec |
15 MB/sec |
30 MB/sec |
40 MB/sec |
6 MB/sec |
11 MB/sec |
16 MB/sec |
36 MB/sec |
Maximum Transfer Rate (library) |
L25: 30 MB/sec
L100: 90 MB/sec |
L25: 30 MB/sec
L100: 90 MB/sec |
L25: 60 MB/sec
L100: 180 MB/sec |
L25: 80 MB/sec
L100: 240 MB/sec |
L25: 12 MB/sec
L100: 36 MB/sec |
L25: 22 MB/sec
L100: 66 MB/sec |
L25: 32 MB/sec
L100: 96 MB/sec |
L25: 72 MB/sec
L100: 216 MB/sec |
1 When using LTO2 200GB media. If using LTO1 (100GB)
media in LTO2 drive, you get 33% better Read/Write performance over
using the same data cartridge in an LTO1 drive.
2 Backward read/write compatible with LTO2; backward read compatible with LTO1.
|
|
Allow at least 12.7 cm (5 in) of space behind