Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Storage J4500 Array: Hardware Specifications


Disks
Capacities: 48 drives per tray. Up to 192 drives in 4 trays.
Drive Specifications Form factor: 3.5 in., low-profile
Type, Density, and Speed
  • 1TB 7200 RPM SATA
  • 750GB 7200 RPM SATA
  • 500GB 7200 RPM SATA *
* - Mixing disk drive capacities is not supported.
Interfaces
Host interfaces/link speeds Four 3 Gb/s SAS total ports per tray
Other interfaces SAS/SATA drive support
Environment
Heat Dissipation
1020 Watts (351.5 BTU/hr.)
AC Power 500 watts (+5V @ 19A/+12V @ 35A)
Input Voltage
90 -264 VAC
Input Frequency
47-63 Hz
Output Power
1500 W
Power Consumption
110 VA, 1100 W maximum
Operating Temperature 0° C to 35° C (32° F to 95° F)
Operating Humidity 20% to 80% humidity, noncondensing
Operating Altitude 0 to 9843 feet
Shock 3.0 G @ 11msec, half-sine wave pulse
Vibration Vertical 0.15G @ 5 Hz to 500 Hz
Horizontal 0.10G @ 5 Hz to 500 Hz
Dimensions and Weights
Height 175.05 mm (6.89 in)
Width 439 mm (17.28 in)
Depth 749.9 mm (29.52 in)
Weight (maximum) 77 kg (169.4 lb)
Regulations
Note: Meets or exceeds the following requirements.
Safety and Emissions FCC Class A, ICES-003, CE, VCCI, CCC, BSMI CNS13438, C-Tick,
GOST R2, MIC, Part 15 47 CFR, EN 55022, EN300-396, CISPR 22,
UL/CUL, UL60950-1, TUV, EN60950-1, IEC60950-1, CB, cULus, GOST R, S-Mark
Rack Mounting
Sun 72-Inch StorEdge Expansion Cabinet, Sun Rack 900/1000 Cabinet, Sun Fire Expansion Cabinet
Availability, Reliability, and Serviceability
No single point of failure due to redundant controllers
Non-disruptive firmware upgrades
Non-disruptive component (major CRU) replacement
Non-disruptive hot-swappable controllers
Non-disruptive hot-swappable disk drives
Dual hot-swappable, redundant, and load-sharing power supplies

 


  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.