Sun Storage J4400, RoHS:YL Array: Hardware Specifications
Disks |
Capacities: |
24 drives per tray. Up to 96 drives in 4 trays. Two-drive minimum. Cannot mix SATA and SAS within same tray.
|
Drive Specifications |
Form factor: 3.5 in., low-profile
Interface: Dual-ported SAS |
Type, Density, and Speed |
- 2TB 7200 RPM SATA
- 1TB 7200 RPM SATA
- 750GB 7500 RPM SATA
- 600GB 15000 RPM SAS
- 500GB 7200 RPM SATA
- 450GB 15000 RPM SAS
- 73GB 15000 RPM SAS
- 146GB 15000 RPM SAS
- 300GB 15000 RPM SAS
|
Interfaces |
Host interfaces/link speeds |
Three 3 Gb/s SAS ports on each SIM module
|
Other interfaces |
SAS/SATA drive support |
Serial |
Up to two RS-232 Serial Mgt ports |
|
Heat Dissipation
|
343.1 BTU/hr. |
AC Power |
500 watts (+5V @ 19A/+12V @ 35A) |
Input Voltage
|
88 -264VAC |
Input Frequency
|
47-63VAC |
Output Power
|
760W |
Power Consumption
|
110.62 VA, 100.0 W |
Operating Temperature |
0° C to 35° C (32°
F to 95° F) |
Operating Humidity |
20% to 95% humidity, noncondensing
|
Operating Altitude |
-50 to 10,000 feet |
Shock |
31 G @ 2.6msec, half-sine wave pulse
|
Vibration |
0.25Gs @ 3 Hz to 200Hz
|
|
Height |
174.8 mm (6.88 in) |
Width |
445 mm (17.52 in) |
Depth |
610.2 mm (24.02 in) including SAS connector
590.3 mm (23.24 in) including thumb screws |
Weight (maximum) |
50 kg (110.23 lb)
|
|
Note: Meets or exceeds the following
requirements. |
Safety and Emissions |
FCC Class A, CE, VCCI, CCC, BSMI: Taiwan/CNS/3438, C-Tick,
UL/CUL, UL60950-1, TVU, EN60950-1, IEC60950-1 |
|
Sun 72-Inch StorEdge Expansion Cabinet, Sun Rack 900/1000 Cabinet, Sun Fire Expansion Cabinet |
Availability, Reliability, and Serviceability
|
No single point of failure due to redundant controllers
Non-disruptive firmware upgrades
Non-disruptive component (major CRU) replacement
Non-disruptive hot-swappable controllers
Non-disruptive hot-swappable disk drives
Dual hot-swappable, redundant, and load-sharing power supplies |
|
|