Sun Storage J4200, RoHS:YL Array: Hardware Specifications
|
|
|
| Disk Configuration |
| Sun Storage J4200, RoHS:YL Array |
Up to twelve disk drives as follows:
- 73GB 15000 RPM, 3 Gb/sec SAS
- 146GB 15000 RPM, 3 Gb/sec SAS
- 300GB 15000 RPM, 3 Gb/sec SAS
- 400GB 10000 RPM, 3 Gb/sec SAS
- 250GB 7200 RPM SATA
- 500GB 7200 RPM SATA
- 750GB 7500 RPM SATA
- 1TB 7200 RPM SATA
- 2TB 7200 RPM SATA
|
|
|
|
| Supported drives/system per tray capacity:raw, unformatted |
| 73GB SAS Disk drives |
12 × 73GB = 876GB |
| 146GB SAS Disk drives |
12 × 146GB = 1.75TB |
| 300GB SAS Disk drives |
12 × 300GB = 3.6TB |
| 400GB SAS Disk drives |
12 × 400GB = 4.8TB |
| 250GB SATA Disk drives |
12 × 250GB = 3.0TB |
| 500GB SATA Disk drives |
12 × 500GB = 6.0TB |
| 750GB SATA Disk drives |
12 × 750GB = 9TB |
| 1TB SATA Disk Drives |
12 × 1TB = 12.0TB |
| 2TB SATA Disk Drives |
12 × 2TB = 24.0TB |
| Drive Specifications |
Form factor: 3.5 in., low-profile
Interface: Dual-ported SAS |
| Interfaces |
| Host interfaces/link speeds |
Two 3 Gb/s "x4 wide" SAS host interfaces
|
| Other interfaces |
SAS/SATA drive support |
| Serial |
Up to two RS-232 Serial Mgt ports |
|
|
Heat Dissipation
|
344.47 BTU/hr. |
| AC Power |
500 watts (+5V @ 19A/+12V @ 35A) |
Input Voltage
|
88 -264VAC |
Power Consumption
|
106.54 VA, 100.4 W |
| Operating Temperature |
0° C to 35° C (32°
F to 95° F) |
| Operating Relative Humidity |
20% to 95% relative humidity, noncondensing
|
| Operating Altitude |
-50 to 10,000 feet |
| Shock |
31 Gs, 2.6msec, half-sine wave pulse
|
| Vibration |
0.25Gs @ 3 Hz to 200Hz
|
|
|
| Height |
87.4 mm (3.44 in) |
| Width |
445 mm (17.52 in) |
| Depth |
619.39 mm (24.39 in) including bezel and SAS connector
610.4 mm (24.03 in) including bezel and power supply handles |
| Weight (maximum) |
28 kg (61.73 lb) with 12 disks
|
|
|
| Note: Meets or exceeds the following
requirements. |
| Safety and Emissions |
FCC Class A, CE, VCCI, CCC, BSMI: Taiwan/CNS/3438, C-Tick,
UL/CUL, UL60950-1, TVU, EN60950-1, IEC60950-1 |
|
|
| Sun 72-Inch StorEdge Expansion Cabinet, Sun Rack 900/1000 Cabinet, Sun Fire Expansion Cabinet |
Clearance and Service Access
|
| Front |
25 cm (9.84 in) for cooling
|
| Rear |
35 cm (13.78 in) for cooling
|
| Top |
20 cm (7.87 in) for cooling
|
Availability, Reliability, and Serviceability
|
No single point of failure due to redundant controllers
Non-disruptive firmware upgrades
Non-disruptive component (major CRU) replacement
Non-disruptive hot-swappable controllers
Non-disruptive hot-swappable disk drives
Dual hot-swappable, redundant, and load-sharing power supplies |
|
|