18.2GB |
Fujitsu MAN3184MC (18.2GB) 1" Height
LVD Disk Drive, Ultra 3 SCSI / Ultra SCSI 160
Seagate ST318305LC (18.2GB) 1" Height LVD Disk Drive, Ultra 3 SCSI
/ Ultra SCSI 160 |
36.4GB |
Fujitsu MAN3367MC (36.4GB) 1" Height
LVD Disk Drive, Ultra 3 SCSI / Ultra SCSI 160
Seagate ST336605LC (36.4GB) 1" Height LVD Disk Drive, Ultra 3 SCSI
/ Ultra SCSI 160 |
73.4GB |
Seagate ST336605LC (73.4GB) 1" Height LVD Disk Drive, Ultra-320 SCSI |
|
Up to 436GB (12 X 36.4GB disks) |
|
AC input |
100 - 240 VAC, 47 - 63 Hz, 2.5 A |
Input power |
260 W |
Heat output |
1092 BTU/hr |
Temperature |
Operating: 5° C to 40° C
(41° F to 104° F)
Nonoperating: -20° C to 60° C (-4° F to 140° F) |
Humidity |
Operating: 20% to 80% relative humidity,
non-condensing
Nonoperating: 10% to 93% relative humidity, non-condensing |
Altitude |
Operating: -30 m to 3000 m (-100
ft. to 10,000 ft.)
Nonoperating: - 30 m to 12,000 m (-100 ft. to 40,000 ft.) |
Acoustic Noise |
Operating: 6.6 Bels
Idling: 6.4 Bels |
Vibration |
Operating: 1.0 G , 5 - 500 Hz (swept
sinewave) |
Shock |
Operating: 15 G peak, 11 milliseconds
(half sinewave) |
Number of cords |
2 |
|
Safety |
UL 1950, CSA C22.2-No. 950, TUV EN 60950 |
Emission |
FCC Part 15 B Class B, CISPR 22 Class B,
VCCI Class 2 |
Immunity |
EMC Directive (89/336/EEC), EN50082-1 |
Harmonics |
EMC Directive (89/336/EEC) EN60555-2 |
|
Height |
17.8 cm (7.0 in.) |
Width |
44.7 cm (17.6 in.) |
Depth |
53.3 cm (21.0 in.) |
Weight |
19.3 kg (42.5 lb.) without drives
28.4 kg (62.5 lb.) with drives |