Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorEdge[tm] C4 Library: Hardware Specifications

LTO2 LTO2 Low Voltage Differential (LVD) 200 GB SCSI Tape Drive
LTO3 LTO3 LVD 400 GB SCSI Tape Drive
SDLT 600 SDLT 600 LVD 300 GB SCSI Tape Drive
The C4 Library:
  • Supports up to two of the above listed tape drive models
  • Supports mixed media provided SLDT600 and LTO2/LTO3 media magazines are installed within the library
  • Has two (2) HD68-pin SCSI connectors on the tape drive for interfaces
  • Has two (2) VHDCI68-pin SCSI connectors on the robotics card for interfaces
AC Voltage Range 90 to 264 VAC
Frequency 47 to 63 Hz
Power Consumption Typical: 200W
Maximum: 250W
Heat Output 3070 BTU/Hr Fully Populated
Heat Dissipation 300W
Power Cable US NEMA 5-15P
Temperature & Humidity Operating: 10° C to 35° C (50° F to 95° F), 20% to 80% noncondensing
Nonoperating: -40° C to 65° C (-40° F to 149° F), 10% to 90% noncondensing
Altitude Operating: -153 to 3048 M (-500 to 10000 ft)
Nonoperating: -153 to 12192 M (-500 to 40000 ft)
Noise (in accordance with ISO 9296) Operating: 7.5 Bels
Idle: 7.0 Bels
Shock 4.0 g, 11 msec, half-sine, applied in all six directions
Vibration 0.21gRMS (random)
0.25 g (5-500 Hz, 5 sweeps), operating axis (bottom)
Height 171 mm (6.75 in)
Width 482 mm (19 in)
Depth 787 mm (31 in)
Weight (without drives) 39 kg (87 lb)
Safety UL-1950, CSA 950, EN60950
RFI/EMI FCC CFR 47-15J (Level A), EN55022 (CISPR 22) Level A, EN 55024 (CISPR 24), VCCI
Agency Markings CE, VCCI, UL, FCC, CSA
This section provides capacity and performance specifications for one (1) Sun StorEdge C4 Library module.
The C4 Library supports a rack-mounted configuration and has the following characteristics:
  • Up to nine (9) C4 Libraries can be installed in the Sun Rack 900-38.
  • Up to nine (9) C4 Libraries can be installed in the Sun Rack 1000-38.
  • Up to ten (10) C4 Libraries can be installed in the Sun Rack 1000-42.
  • The library has a built-in pass-through port that allows other C4 Libraries to be stacked in a rack and the tape cartridges can be passed between the libraries.
  • No additional hardware is needed to utilize the scalability feature of the pass-through port.
Item LTO2 LTO3 SDLT600
Number of Tape Drives 2 2 2
Number of Cartridges 38 38 32
Cartridge Capacity (native)1 200 GB 400 GB 300 GB
Cartridge Capacity (compressed)2 400 GB 800 GB 600 GB
Maximum Library Capacity (native)1 7.6 TB 15.2 TB 9.6 TB
Maximum Library Capacity (compressed)2 15.2 TB 30.4 TB 19.2 TB
Drive Sustained Transfer Rate (1 drive) 30 MB/sec 80 MB/sec 36 MB/sec
Maximum Transfer Rate (library with 2 drives, native)1 216.0 GB/hr 576.0 GB/hr 259.2 GB/hr
Maximum Transfer Rate (library with 2 drives, compressed)2 432.0 GB/hr 1152.0 GB/hr 518.4 GB/hr
1Native represents the capacity without compression.
2Compressed identifies a capacity compression ratio of 2:1.
Allow adequate space behind the library for proper ventilation.
The Sun StorEdge C4 tape library fits into and is supported in the following racks:
  • Sun Rack 900-38
  • Sun Rack 1000-38
  • Sun Rack 1000-42

 


  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.