Sun StorEdge[tm] A3500FC Array: Hardware Specifications

9GB Seagate ST39102LC 9.1GB 10000 RPM 1" Height Disk Drive
Seagate ST39103LC 9.1GB 10000 RPM 1" Height Disk Drive
Fujitsu MAG3091LC 9.1GB 10000 RPM 1" Height Disk Drive
18GB Seagate ST318203LC 18.2GB 10000 RPM 1" Height Disk Drive
Fujitsu MAG3182LC 18.2GB 10000 RPM 1" Height Disk Drive
36GB Seagate ST136403LC 36.4GB 10000 RPM 1 5/8" Height Disk Drive
Fujitsu MAF3364LC 36.4GB 10000 RPM 1 5/8" Height Disk Drive
Seagate ST336704LC 36.4GB 10000 RPM 1" Height Disk Drive
Fujitsu MAJ3364MC 36.4GB 10000 RPM 1" Height Disk Drive
Up to 3.2TB using 18GB drives and up to 6.5TB using 36GB drives.
AC input 200 - 240 VAC, 50 - 60 Hz, 24 A(PDU max rating)
Input power 646 W(min) to 6131 W(max)
Heat output 1 2206 BTU/hr(min) to 20925 BTU/hr(max)
Temperature 2 Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -10° C to 60° C (-14° F to 140° F)
Humidity Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 93% relative humidity, noncondensing
Altitude Operating: -30 m to 3000 m (-100 ft. to 10,000 ft.)
Nonoperating: -30 m to 12,000 m (-100 ft. to 40,000 ft.)
Number of cords 1
1 - Minimum configuration: 1x5, 18-GB drives(minimum); Maximum configuration: 3x15, 36-GB drives(maximum)
2 - If removable tape media is installed in the Sun StorEdge A3500FC array cabinet, the operating temperature range is 10° C to 32° C (50° F to 90° F).
Safety UL 1950, CSA C22.2-No. 950, TUV-EN60950, CB Scheme (to IEC 950 and Nordic Deviations)
RFI/EMI VCCI Class 1, FCC Class A, DOC Class A, EN55022 Class A, EN61000-3-2
Immunity EN50082-1
Product Label FCC Class A, VCCI Class 1, Industry Canada Class A, UL Mark, cUL Mark, TUV Mark, CE Mark
Height 187 cm (73.5 in.)
Width 61 cm (24 in.)
Depth 93 cm (36.5 in.)
Weight (rack with sequencers) 159 kg (350 lb.)
Front 122 cm (48 in.)
Rear 92 cm (36 in.)
Sides 1 92 cm (36 in.)
1 - side access required for some service procedure

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback