Number of disk drives (with spares) |
5 to 1152 |
Hot spares (maximum) |
1 - 40 |
Individual disk capacities |
72GB (15K RPM)
72GB (15K RPM)
146GB (10K RPM)
146GB (15K RPM)
300GB (10K RPM)
300GB (15K RPM)
|
Total raw capacity per system (72GB drive) |
72GB x 1152 = 82.944TB1 |
Total raw capacity per system (146GB drive) |
146GB x 1152 = 168.192TB1 |
Total raw capacity per system (300GB drive) |
300GB x 1152 = 345.6TB1 |
1 This is total raw capacity, using 1152 disk drives (maximum), with no spare drives.
|
|
Maximum |
128GB |
Minimum |
4GB |
Increments |
4GB |
|
Up to 6GB |
|
Up to 16,384 |
|
Number of Front End Directors |
6 |
Number of Simultaneous Data Transfers |
Up to 16 or 32 per Front End Director |
Interface speed (fibre channel) |
2 GB/sec |
|
Number of Back End Directors |
Up to 4 |
Disk Drives per Back End Directors |
Up to 256 Hard Disk Drives |
|
Fibre Channel (fiber-optic cable) |
32, 64, 96, 128, 160, 192 |
ESCON |
16, 32, 64, 80, 96 |
FICON |
8, 16, 24, 32, 40, 48 |
Bandwidth |
Per fully configured system
|
81GB/sec aggregate system bandwidth (consisting of 68GB/sec data
bandwidth, and 13GB/sec control bandwidth) |
|
Power |
Control Frame: 9.077 kVA
Array Frame: 7.636 kVA |
Heat |
Control Frame: 8.68 kW
Array Frame: 7.07 kW |
|
Height |
Control Frame (DKC): 186.0 cm (73.2 in.)
Array Frame (DKU): 186.0 cm (73.2 in.) |
Width |
Control Frame (DKC): 78.2 cm (30.77 in.)
Array Frame (DKU): 65.0 cm (25.59 in.) |
Depth |
Control Frame (DKC): 92.5 cm (36.42 in.)
Array Frame (DKU): 92.5 cm (36.42 in.) |
Weight |
Control Frame (DKC): 590. kg (1300.73 lb.)