Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorageTek[tm] 9985V System, RoHS:YL: Hardware Specifications

Number of disk drives (with spares) Up to 240
Hot spares (maximum) 16
Individual disk capacities 72GB (Flash Drive)
73GB (15K RPM)
146GB (15K RPM)
146GB (Flash Drive)
200GB (Flash Drive)
300GB (15K RPM)
300GB (10K RPM)
400GB (10K RPM)
450GB (15K RPM)
750GB (7.2K RPM)
     1TB (7.2K RPM)
Total raw capacity per system (73GB drive) 17.52TB
Total raw capacity per system (146GB drive) 35.04TB
Total raw capacity per system (300GB drive) 72TB
Total raw capacity per system (400GB drive) 96.0TB
Total raw capacity per system (450GB drive) 108.0TB
Total raw capacity per system (750GB drive) 180.0TB
Total raw capacity per system (1TB drive) 240.0TB
Supported RAID Levels RAID 1, RAID 5, RAID 6
Maximum 64GB
Minimum 4GB
Increments 2GB
Maximum 16GB
Minimum 4GB
Maximum of 1
Up to 65,536
Front End Directors (Channel Adapters) 1-3, 16 FC ports per director
Back End Directors (Channel Adapters) 1
Fibre Channel (fiber-optic cable) 16-48 2Gb FC Host Ports
ESCON Up to 24 Host Ports
FICON Up to 24 Host Ports
NAS Supports C-NAS
Bandwidth
Aggregate System
13.3GB/sec
Maximum System Data
8.5GB/sec
Maximum System Control
4.8GB/sec
Temperature Operating: 16° to 32° C (60.8° to 89.6° F)
Non-operation: -10° to 43° C (14° to 109.4° F)
Shipping & Storage: -25° to 60° C (5° to 140° F)
Relative Humidity Operating: 20% to 80%
Non-operation: 8% to 90%
Shipping & Storage: 5% to 95%
Maximum Wet Bulb Operating: 26° C (78.8° F)
Non-operation: 27° C (80.6° F)
Shipping & Storage: 29° C (84.2° F)
Temperature Deviation Per Hour Operating: 10° C (50° F)
Non-operation: 10° C (50° F)
Shipping & Storage: 20° C (36° F)
Acoustic Level Operating: 65 dB
Non-operation: n/a
Shipping & Storage: n/a
Height Control Array Frame (DKC615I-5): 438 mm (17.2 in.)
Array Frame (DKC-F615I-B2): 522 mm (20.6 in.)
Service Processor (DKC-F6151-SBX): 84 mm (3.3 in)
Width Control Array Frame (DKC615I-5): 445 mm (17.5 in.)
Array Frame (DKC-F615I-B2): 445 mm (17.5 in.)
Service Processor (DKC-F6151-SBX): 445 mm (17.5 in)
Depth Control Array Frame (DKC615I-5): 800 mm (31.5 in.)
Array Frame (DKC-F615I-B2): 647 mm (25.5 in.)
Service Processor (DKC-F6151-SBX): 800 mm (31.5 in)
Weight Control Array Frame (DKC615I-5): 70 kg (154 lb.)
Array Frame (DKC-F615I-B2): 80.5 kg (177.1 lb.)
Service Processor (DKC-F6151-SBX): 13 kg (28.6 lb)
Geography Frequency Input Voltages (AC) Conditions(%) Tolerance (%)
US 60Hz (+ or - 0.5Hz) 200V, 208V, or 230V 1 Phase (2 Wire + Ground) +6% or -8%
Europe 50Hz (+ or - 0.5Hz) 200V, 220V, 230V, or 240V 1 Phase (2 Wire + Ground) +6% or -8%
Power Supply Modules Battery Backup Modules
Maximum of 2 Maximum of 2
  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.