Number of disk drives (with spares) |
Up to 120 |
Hot spares (maximum) |
16 |
Individual disk capacities |
73GB (15K RPM)
146GB (10K RPM)
300GB (10K RPM)
|
Total raw capacity per system (73GB drive) |
8.76TB (120 disk drives x 73GB = 8.76TB) |
Total raw capacity per system (146GB drive) |
17.52TB (120 disk drives x 146GB = 17.52TB) |
Total raw capacity per system (300GB drive) |
36TB (120 disk drives x 300GB = 36TB) |
Supported RAID Levels |
RAID 1, RAID 5, RAID 6 |
|
Maximum |
64GB |
Minimum |
4GB |
Increments |
2GB |
|
Maximum |
6GB |
Minimum |
2GB |
|
Maximum of 1 |
|
Up to 16,384 |
|
Front End Director (FED) Ports |
16 FC |
Back End Director (BED) Ports |
8 FC |
1The "mixed adapter" is new and unique to the Sun StorEdge 9985 system; the mixed adapter
is a combination of FED and BED. This adapter can only be used in slots 1A and 2F. |
|
Number of Slots |
2 |
Designated Slots |
1B and 2E |
2The "optional slots" are for multi-purpose use. These slots can accommodate FED (CHA),
NAS Blade (CHN), and mainframe adapters such as, FICON and ESCON. |
|
Fibre Channel (fiber-optic cable) |
16-48 2Gb FC Host Ports |
ESCON |
Up to 16 Host Ports |
FICON |
Up to 8 Host Ports |
NAS |
Up to 8 1Gb NAS Ports |
Bandwidth |
Aggregate System
|
12GB/sec |
Maximum System Data
|
8.5GB/sec |
Maximum System Control
|
3.5GB/sec |
|
Temperature |
Operating: 16° to 32° C (60.8° to 89.6° F)
Non-operation: -10° to 43° C (14° to 109.4° F)
Shipping & Storage: -25° to 60° C (-13° to 140° F)
|
Relative Humidity |
Operating: 20% to 80%
Non-operation: 8% to 90%
Shipping & Storage: 5% to 95%
|
Maximum Wet Bulb |
Operating: 26° C (78.8° F)
Non-operation: 27° C (80.6° F)
Shipping & Storage: 29° C (84.2° F)
|
Temperature Deviation Per Hour |
Operating: 10° C (50° F)
Non-operation: 10° C (50° F)
Shipping & Storage: 20° C (68° F)
|
Acoustic Level |
Operating: 65 dB
Non-operation: n/a
Shipping & Storage: n/a
|
|
Height |
Control Array Frame (DKC515I-5/5R): 703 mm (27.7 in.)4
Array Frame (DKC-F515I-B2R): 522 mm (20.6 in.) |
Width |
Control Array Frame (DKC515I-5/5R): 480 mm (18.9 in.)
Array Frame (DKC-F515I-B2R): 480 mm (18.9 in.) |
Depth |
Control Array Frame (DKC515I-5/5R): 648 mm (25.5 in.)
Array Frame (DKC-F515I-B2R): 648 mm (25.5 in.) |
Weight5 |
Control Array Frame (DKC515I-5/5R): 82 kg (180.8 lb.)
Array Frame (DKC-F515I-B2R): 66 kg (145.5 lb.) |
3Allow 596 mm (23.47 in.) in the rear of the unit for service clearance.
4This dimension includes the thickness of the SVP 43.2 mm (1.7 in.).
5Refer to the Sun StorEdge 9985 Array documentation for a list of all
component weights within the system.
|