Sun StorEdge[tm] 6920 System: Hardware Specifications

Disks
36GB
  • Seagate ST336752FC, 36GB - 15000 RPM, FC-AL
  • Seagate ST336753FC, 36GB - 15000 RPM, FC-AL
  • Fujitsu MAS3367FC, 36GB - 15000 RPM, FC-AL
  • Fujitsu MAU3367FC, 36GB - 15000 RPM, FC-AL
73GB
  • Seagate ST373207FC, 73GB - 10000 RPM, FC-AL
  • Seagate ST373307FC, 73GB - 10000 RPM, FC-AL
  • Seagate ST373453FC, 73GB - 15000 RPM, FC-AL
  • Fujitsu MAT3073FC, 73GB - 10000 RPM, FC-AL
  • Fujitsu MAP3735FC, 73GB - 10000 RPM, FC-AL
  • Fujitsu MAS3735FC, 73GB - 15000 RPM, FC-AL
  • Fujitsu MAU3073FC, 73GB - 15000 RPM, FC-AL
  • Hitachi DK32EJ-72FC, 73GB - 10000 RPM, FC-AL
  • Hitachi HUS1073FA, 73GB - 10000 RPM, FC-AL
146GB
  • Seagate ST3146707FC, 146GB - 10000 RPM, FC-AL
  • Seagate ST3146807FC, 146GB - 10000 RPM, FC-AL
  • Fujitsu MAP3147FC, 146GB - 10000 RPM, FC-AL
  • Fujitsu MAT3147FC, 146GB - 10000 RPM, FC-AL
  • Fujitsu MAW3147FC, 146GB - 10000 RPM, FC-AL
  • Hitachi DK32EJ-14FC, 146GB - 10000 RPM, FC-AL
  • Hitachi HUS1014FA, 146GB - 10000 RPM, FC-AL
300GB
  • Seagate ST3300007FC (300GB - 10000 RPM FC-AL)
  • Seagate ST3300007FC (300GB - 10000 RPM FC-AL), RoHS
  • Fujitsu MAT3300FC (300GB - 10000 RPM FC-AL)
  • Fujitsu MAW3300FC (300GB - 10000 RPM FC-AL), RoHS
Capacity
2 x 2 Configuration 2 Controllers and 2 Array trays (28 disks) using 300GB disks - 8.4TB
2 x 4 Configuration 2 Controllers and 4 Array trays (56 disks) using 300GB disks - 16.8TB
2 x 6 Configuration 2 Controllers and 6 Array trays (84 disks) using 300GB disks - 25.2TB
Note 1: This is raw capacity; if a disk is used for a "hot spare", you must subtract this capacity from the total raw capacity.
Note 2: An expansion cabinet can be added to the configuration to increase total storage capacity.
Environment
AC input 200 to 240 VAC at 50 to 60 Hz single phase
Input power Base Unit: 4200 W maximum, two dedicated 200 to 220 VAC, 30A circuit breakers
Base Unit + Expansion Cabinet: 8,400 W maximum, four dedicated 200 to 220 VAC, 30A circuit breakers
Base Unit + 2 Expansion Cabinets: 12,600 W maximum, six dedicated 200 to 220 VAC, 30A circuit breakers
Heat output Base Unit: ~15,000 BTU/hr
Base Unit + Expansion Cabinet: ~28,000 BTU/hr
Base Unit + 2 Expansion Cabinets: ~28,000 BTU/hr
Temperature Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 60° C (-40° F to -76° F)
Humidity Operating: 10% to 90%, noncondensing, maximum gradient 10% per hour
Nonoperating: 93%, noncondensing, maximum gradient 10% per hour
Altitude Operating: 3000 m (9840 ft )
Nonoperating: 12000 m (39,370 ft)
Vibration Operating: 0.15 g on Z axis; 0.10 g on X and Y axes; 5 to 500 Hz sinusoidal
Nonoperating: 0.5 g on Z axis; 0.25 g on X and Y axes; 5 to 500 Hz sinusoidal
Shock Operating: 3.0 g for maximum duration of 11 ms (half sinewave)(from any axis X, Y, Z)
Nonoperating: 1.0 inch roll-off freefal, front to back rolling directions (from any axis X, Y, Z)
Power Connector (US) NEMA L6-30P for 200 to 240 VAC
Power Connector (International) 32A, single phase IEC 309, connected for 220 to 240 VAC
Regulations
Meets or exceeds the following requirements:
Immunity EN55024
Safety and Emissions IEC60950, EN60950, UL60950, FCC Part 15 (47CFR15B), EN55022, EN 61000-3-2, EN 61000-3-3
Dimensions and Weights
Height Base Unit: 190.5 cm (75 in)
Base Unit + Expansion Cabinet: 190.5 cm (75 in)
Base Unit + 2 Expansion Cabinets: 190.5 cm (75 in)
Width Base Unit: 60.7 cm (23.9 in)
Base Unit + Expansion Cabinet: 121.4 cm (47.8 in)
Base Unit + 2 Expansion Cabinets: 182.1 cm (71.7 in)
Depth Base Unit: 94 cm (37 in)
Base Unit + Expansion Cabinet: 94 cm (37 in)
Base Unit + 2 Expansion Cabinets: 94 cm (37 in)
Weight Base Unit: 659 kg (1450 lbs)
Base Unit + Expansion Cabinet: 1364 kg (3000 lbs)
Base Unit + 2 Expansion Cabinets: 2068 kg (4550 lbs)
Footprint Base Unit: 0.57 sq. m (6.1 sq. ft)
Base Unit + Expansion Cabinet: 1.4 sq. m (12.3 sq. ft)
Base Unit + 2 Expansion Cabinets: 1.7 sq. m (18.4 sq. ft)
Clearance and Service Access
Front 122 cm (48 in)
Rear 92 cm (36 in)

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback