36GB
  • Seagate ST336752FC, 36GB - 15000 RPM, FC-AL
  • Seagate ST336753FC, 36GB - 15000 RPM, FC-AL
  • Fujitsu MAS3367FC, 36GB - 15000 RPM, FC-AL
73GB
  • Seagate ST373307FC, 73GB - 10000 RPM, FC-AL
  • Fujitsu MAP3735FC, 73GB - 10000 RPM, FC-AL
  • Hitachi DK32EJ-72FC, 73GB - 10000 RPM, FC-AL
  • Seagate ST373453FC, 73GB - 15000 RPM, FC-AL
  • Fujitsu MAS3735FC, 73GB - 15000 RPM, FC-AL
146GB
  • Seagate ST3146807FC, 146GB - 10000 RPM, FC-AL
  • Fujitsu MAP3147FC, 146GB - 10000 RPM, FC-AL
  • Hitachi DK32EJ-14FC, 146GB - 10000 RPM, FC-AL
Capacity
Base Unit: Up to 20.4 TB
Base Unit + Expansion Cabinet: Up to 45.0 TB
AC input 200 to 240 VAC at 47 to 63 Hz single phase
Input power Base Unit: 4200 W maximum, two dedicated 200 to 220 VAC, 30A circuit breakers
Base Unit + Expansion Cabinet: 8,400 W maximum, four dedicated 200 to 220 VAC, 30A circuit breakers
Heat output Base Unit: ~15,000 BTU/hr
Base Unit + Expansion Cabinet: ~28,000 BTU/hr
Temperature Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 60° C (-40° F to 140° F)
Humidity Operating: 10% to 90%, noncondensing, maximum gradient 10% per hour
Nonoperating: 93%, noncondensing, maximum gradient 10% per hour
Altitude Operating: -305 m to 3048 m (-1000 ft to 10000 ft)
Nonoperating: -305 m to 12192 m (-1000 ft to 40000 ft)
Vibration Operating: 0.15 g on Z axis; 0.10 g on X and Y axes; 5 to 500 Hz sinusoidal
Nonoperating: 0.5 g on Z axis; 0.25 g on X and Y axes; 5 to 500 Hz sinusoidal
Shock Operating: 3.0 g for maximum duration of 11 ms (half sinewave)(from any axis X, Y, Z)
Nonoperating: 1.0 inch roll-off freefal, front to back rolling directions (from any axis X, Y, Z)
Power Connector (US) NEMA L6-30P for 200 to 240 VAC (two per cabinet)
Power Connector (International) 32 A, single phase IEC 309 connected to 200 to 240 VAC (two per cabinet)
Power Cables Two NEMA 5-15P
RFI/EMI EN55022, FCC 47CFR Part 15 Class A, EN61000-3-2, EN61000-3-3 EN55024
Safety and Emissions UL 1950, 3rd Ed., EN 60950:1992, 2nd Ed.+A1+A2+A3+A4+A11 CSA-C22.2 No. 950, IEC 60950:1991, 2nd Ed.+A1+A2+A3+A4+A11 TUV CB Scheme with all national differences
Height Base Unit: 190.5 cm (75 in)
Base Unit + Expansion Cabinet: 190.5 cm (75 in)
Width Base Unit: 60.7 cm (23.9 in)
Base Unit + Expansion Cabinet: 121.4 cm (47.8 in)
Depth Base Unit: 94 cm (37 in)
Base Unit + Expansion Cabinet: 94 cm (37 in)
Weight Base Unit: 771 kg (1700 lbs)(Full complement of Sun StorEdge[tm] 6020 arrays)
Base Unit + Expansion Cabinet: 1633 kg (3600 lbs) (Full complement of Sun StorEdge[tm] 6020 arrays)
Footprint Base Unit: 0.5706 sq. m (6.14 sq. ft)
Base Unit + Expansion Cabinet: 1.411 sq. m (12.29 sq. ft)
Clearance and Service Access
Front 122 cm (48 in)
Rear 92 cm (36 in)

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.