36GB |
- Seagate ST336752FC, 36GB - 15000 RPM, FC-AL
- Seagate ST336753FC, 36GB - 15000 RPM, FC-AL
- Fujitsu MAS3367FC, 36GB - 15000 RPM, FC-AL
|
73GB |
- Seagate ST373307FC, 73GB - 10000 RPM, FC-AL
- Fujitsu MAP3735FC, 73GB - 10000 RPM, FC-AL
- Hitachi DK32EJ-72FC, 73GB - 10000 RPM, FC-AL
- Seagate ST373453FC, 73GB - 15000 RPM, FC-AL
- Fujitsu MAS3735FC, 73GB - 15000 RPM, FC-AL
|
146GB |
- Seagate ST3146807FC, 146GB - 10000 RPM, FC-AL
- Fujitsu MAP3147FC, 146GB - 10000 RPM, FC-AL
- Hitachi DK32EJ-14FC, 146GB - 10000 RPM, FC-AL
|
Capacity |
Base Unit: Up to 20.4 TB
Base Unit + Expansion Cabinet: Up to 45.0 TB |
|
AC input |
200 to 240 VAC at 47 to 63 Hz single phase |
Input power |
Base Unit: 4200 W maximum, two dedicated 200
to 220 VAC, 30A circuit breakers
Base Unit + Expansion Cabinet: 8,400 W maximum, four dedicated 200
to 220 VAC, 30A circuit breakers |
Heat output |
Base Unit: ~15,000 BTU/hr
Base Unit + Expansion Cabinet: ~28,000 BTU/hr |
Temperature |
Operating: 5° C to 35° C (41° F to
95° F)
Nonoperating: -40° C to 60° C (-40° F to 140° F) |
Humidity |
Operating: 10% to 90%, noncondensing, maximum
gradient 10% per hour
Nonoperating: 93%, noncondensing, maximum gradient 10% per hour |
Altitude |
Operating: -305 m to 3048 m (-1000 ft to 10000
ft)
Nonoperating: -305 m to 12192 m (-1000 ft to 40000 ft) |
Vibration |
Operating: 0.15 g on Z axis; 0.10 g on X and
Y axes; 5 to 500 Hz sinusoidal
Nonoperating: 0.5 g on Z axis; 0.25 g on X and Y axes; 5 to 500 Hz
sinusoidal |
Shock |
Operating: 3.0 g for maximum duration of 11 ms
(half sinewave)(from any axis X, Y, Z)
Nonoperating: 1.0 inch roll-off freefal, front to back rolling directions
(from any axis X, Y, Z) |
Power Connector (US) |
NEMA L6-30P for 200 to 240 VAC (two per cabinet) |
Power Connector (International) |
32 A, single phase IEC 309 connected to 200 to 240 VAC
(two per cabinet) |
Power Cables |
Two NEMA 5-15P |
|
RFI/EMI |
EN55022, FCC 47CFR Part 15 Class A, EN61000-3-2, EN61000-3-3
EN55024 |
Safety and Emissions |
UL 1950, 3rd Ed., EN 60950:1992, 2nd Ed.+A1+A2+A3+A4+A11
CSA-C22.2 No. 950, IEC 60950:1991, 2nd Ed.+A1+A2+A3+A4+A11 TUV CB Scheme
with all national differences |
|
Height |
Base Unit: 190.5 cm (75 in)
Base Unit + Expansion Cabinet: 190.5 cm (75 in) |
Width |
Base Unit: 60.7 cm (23.9 in)
Base Unit + Expansion Cabinet: 121.4 cm (47.8 in) |
Depth |
Base Unit: 94 cm (37 in)
Base Unit + Expansion Cabinet: 94 cm (37 in) |
Weight |
Base Unit: 771 kg (1700 lbs)(Full complement
of Sun StorEdge[tm] 6020 arrays)
Base Unit + Expansion Cabinet: 1633 kg (3600 lbs) (Full complement
of Sun StorEdge[tm] 6020 arrays) |
Footprint |
Base Unit: 0.5706 sq. m (6.14 sq. ft)
Base Unit + Expansion Cabinet: 1.411 sq. m (12.29 sq. ft) |
Clearance and Service Access
|
Front |
122 cm (48 in) |
Rear |
92 cm (36 in) |