|
36.4 GB |
- Seagate ST136403FC, 36.4GB - 10000 RPM, FC-AL
- Seagate ST336704FC, 36.4GB - 10000 RPM, FC-AL
- Seagate ST336605FC, 36.4GB - 10000 RPM, FC-AL
- Seagate ST336607FC, 36.4GB - 10000 RPM, FC-AL
- Fujitsu MAN3367FC, 36.4GB - 10000 RPM, FC-AL
- IBM DDYF-T36950, 36.4GB - 10000 RPM, FC-AL
- Seagate ST336752FC, 36.4GB - 15000 RPM, FC-AL
- Seagate ST336753FC, 36.4GB - 15000 RPM, FC-AL
- Fujitsu MAS3367FC, 36.4GB - 15000 RPM, FC-AL
|
73.4 GB |
- Seagate ST173404FC, 73.4GB - 10000 RPM, FC-AL
- Seagate ST373405FC, 73.4GB - 10000 RPM, FC-AL
- Seagate ST373307FC, 73.4GB - 10000 RPM, FC-AL
- Fujitsu MAN3735FC, 73.4GB - 10000 RPM, FC-AL
- Fujitsu MAP3735FC, 73.4GB - 10000 RPM, FC-AL
- Hitachi DK32EJ-72FC, 73.4GB - 10000 RPM, FC-AL
|
181 GB |
- Seagate ST1181677FCV, 181.5GB - 7200 RPM, FC-AL
|
|
3900: 655 GB to 29 TB
6900: 655 GB to 26 TB |
|
500MHz, 64-bit UltraSPARC IIe |
|
Minimum 512MB, expandable to 1GB |
|
AC Power |
200 - 240 VAC @ 47 to 53 Hz Single phase |
Heat Output |
3910: ~14000 BTU
3960: ~26000 BTU1
6910: ~14000 BTU
6960: ~26000 BTU1 |
Temperature |
Operating: 5° C to 35°
C (41° F to 95° F)
Nonoperating: -20° C to 60° C (-4° F to 140°
F) |
Humidity |
Operating: 20% to 80% relative humidity,
noncondensing s7° C (80.6° F) maximum wet bulb
Nonoperating: 5% to 93% relative humidity, noncondensing |
Altitude |
Operating: -305 to 3048 meters (-1000
to 10000 feet)
Nonoperating: -305 to 12192 meters (-1000 to 40000 feet) |
Shock |
Operating: 4.0g for maximum duration
of 11ms (half-sinewave)
Nonoperating: 10.0g for maximum duration of 11ms (half-sinewave) |
Vibration |
Operating: 5 to 500 Hz @ 0.25g sinusoidal
Nonoperating: 5 to 500 Hz @ 1.0g sinusoidal |
1 - 3960 and 6960
values include the Sun StorEdge Expansion Cabinet. |
|
Height |
190.5 cm (75 in.) |
Width |
3910: 60.7 cm (23.9 in.)
3960: 122 cm (47.8 in.)
6910: 60.7 cm (23.9 in.)
6960: 122 cm (47.8 in.) |
Depth |
94 cm (37 in.) |
Weight1 |
3910: 665 kg (1466 lbs.)
3960: 1295 kg (2855 lbs.)2
6910: 549 kg (1210 lbs.)
6960: 1314 kg (2896 lbs.)2 |
Power Cord |
4.6 m (15 ft.) |
1 - Values given
are for the maximum hardware configuration available.
2 - 3960 and 6960 values include the Sun StorEdge
Expansion Cabinet. |
Regulations
Meets or exceeds the following requirements:
|
Safety |
IEC 60950, EN 60950, UL 60950, UL 1950, FCC Part 15 (47CRF15B),
CISPR 22 (EN55022 - RF Radiated and Conducted Emissions), IEC 61000-3-2,
IEC 61000-3-3 |
Immunity |
CISPR 24 (EN55024), IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4,
IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 |
|
Front |
With Service Access: 122 cm (48 in.)
Without Service Access: 61cm (24 in.) |
Rear |
With Service Access: 92 cm (36 in.)
Without Service Access: 61 cm (24 in.) |
Left1 |
With Service Access: 92 cm (36 in.)
Without Service Access: 5 cm (2 in.)2 |
Right1 |
With Service Access: 92 cm (36 in.)
Without Service Access: 0 |
1 - Side access may be required
for some service procedures. Refer to the documentation that came with the
devices.
2 - Sun StorEdge A5x00 disk array, Sun Enterprise
4x00 servers, and some other devices require a clearance of at least two
inches for airflow. Unless otherwise stated in the documentation that shipped
with your device, no clearance access is required. |