Sun StorEdge 3900 series : Sun Alerts


Sun Alert Former ID Synopsis Last Modified Date
1019245.1 237605 Sun StorageTek T3+ (T3B) Array and Sun StorageTek 6120, 6320 and 6920 Arrays May Reboot Unexpectedly and Lose Host Connectivity after 994 Days of Continuous Operation 2011-02-17
1000907.1 201217 Sun StoreEdge T3 and T3+ Arrays (Including SE3900 and SE6900 Series) May Reset and/or Briefly Lose Host Connectivity After Running Continuously For 497 Days 2011-03-07
1000879.1 201160 Loss of SAN Storage Path Following Link Event or Configuration Change 2011-03-01
1000860.1 201141 Certain SAN Switches May Reboot Following "break" Sequences Received on the Serial Port 2011-02-22
1000405.1 200533 The Use of Certain sscs(1M) Commands, Array/StorEdge 3900SL CLI Commands, or Certain StorEdge 3900SL/6320 GUI Actions to Manage a Sun StorEdge 3900SL/6120/6320/T3+ Array, Attached via Certain FC Switches, May Cause Loss of Connectivity to a Host(s) 2011-03-01
1000356.1 200478 Certain sscs(1M) Commands, Array/StorEdge 3900SL CLI Commands, or Certain StorEdge 3900SL/6320/6130 GUI Actions May Cause Loss of Connectivity to a Host(s) 2011-02-25
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.