Sun StorEdge[tm] 3511 FC Array: Hardware Specifications
|
|
250 GB |
Hitachi 250GB - 7200 RPM, SATA
Disk Drive |
400 GB |
Hitachi 400GB - 7200 RPM, SATA
Disk Drive |
500 GB |
Hitachi 500GB - 7200 RPM, SATA
Disk Drive |
Note 1: All RAID configurations ship pre-configured with RAID level zero (RAID 0).
Note 2: Supported RAID levels include 0, 1, 1+0, 3, 5, 3+0, and 5+0.
|
|
Up to 12 Disk drives per array |
250GB Disk drives |
12 x 250 = 3TB |
400GB Disk drives |
12 x 400 = 4.8TB |
500GB Disk drives |
12 x 500 = 6.0TB |
|
Power Requirement |
AC: 90 to 264 VAC, single phase (47 to 63Hz)
DC: -36 to -75 VDC |
Input Voltage |
AC: 100 to 240 VAC, single phase
DC: -48 to -60 VDC, 18A |
Current Per Input |
AC: Values include:
- 90 VAC (3.51A) to 264 VAC (1.25A), 50 Hz
- 90 VAC (3.56A) to 264 VAC (1.31A), 60 Hz
DC: -48 to -60 VDC, 18A |
Maximum Inrush Current |
115 VAC: 50A peak
230 VAC: 100A peak |
Power Supply Output Voltages |
+5VDC and +12VDC |
Heat Output |
1105 BTU/hr (fully populated array) |
Altitude |
Operating: -30 m to 3,048 m(-100 to 10000 feet)
Non-operating: -30 m to 12192 m(-100 to 40000 feet) |
Temperature |
Operating: 5° C to 40° C (41° F to 104° F)
Non-operating: -40° C to 65° C (-40° F to 149° F) |
Humidity |
Operating: 10% to 90% relative to 27° C max.
wet bulb, noncondensing
Non-operating:) 0% to 90% relative to 38° C max. wet bulb, noncondensing |
Shock |
Operating: 5.0 G, 11-ms, half-sine
Non-operating: 15.0 G, 11-ms, half-sine |
Vibration |
Operating: 0.2 G, 5-500 Hz, swept-sine
Non-operating: 1.0 G, 5-500 Hz, swept-sine |
|
Height |
Desktop: 9.25 cm (3.64 in)
Rackmount: 8.89 cm (3.5 in) |
Width |
Desktop: 48.26 cm (19 in)
Rackmount: 44.7 cm - body only (17.6 in) |
Depth |
Main Chassis: 45.72 cm (18.0 in)
Chassis with Fan Modules: 50.80 cm (20.0 in)
Chassis with Fan Modules and Handles: 53.34 cm (21.5 in) |
Weight |
Fully Loaded 26.8 kg (59.1 lbs)
Packaged Weight (fully loaded): 31.9 kg (70.5 lbs) |
|
Safety |
UL listed CSA-C22.2 No. 60950-00, EN
60950:2000, IEC 60950, GS, GOST, S-Mark |
Emission |
FCC Part 15 Class B, ICES-003, EN 300 386, EN55022 Class B, VCCI Class B, EN AS/NZS 3548 Class B, BSMI Class B |
Harmonics |
EN 61000-3-2, EN 61000-3-3 |
Immunity |
EN300 386, EN 55024 |
Other |
NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F,
ETSI EN 300 019 |
|
Front |
37 cm (15 in) service clearance, 15 cm (6 in) cooling
clearance |
Rear |
37 cm (15 in) service clearance, 15 cm (6 in) cooling
clearance |
Airflow for cooling is from front to rear |
|
Rack mountable in 19" wide rack |
|
|