Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorageTek[tm] 2510 Array: Hardware Specifications


Disks
Disk Configuration
Sun StorageTek 2510 Up to twelve disk drives as follows:
  • 73GB 15000 RPM, 3 Gb/sec SAS
  • 146GB 15000 RPM, 3 Gb/sec SAS
  • 300GB 15000 RPM, 3 Gb/sec SAS
  • 400GB 10000 RPM, 3Gb/sec SAS
  • 450GB 15000 RPM, 3Gb/sec SAS
  • 500GB 7200 RPM, 3Gb/sec SATA-II
  • 750GB 7200 RPM, 3Gb/sec SATA-II
  • 1TB 7200 RPM, 3Gb/sec SATA-II
Capacity
Supported drives/system per tray capacity:raw, unformatted
73GB Disk drives 12 × 73GB = 876GB
146Gb Disk drives 12 × 146GB = 1.75TB
300GB Disk drives 12 × 300GB = 3.6TB
400GB Disk drives 12 × 400GB = 4.8TB
450GB Disk drives 12 × 450GB = 5.4TB
500GB Disk drives 12 × 500GB = 6TB
750GB Disk drives 12 × 750GB = 9TB
1TB Disk drives 12 × 1TB = 12TB
Note 1: Dynamic capacity expansion of 5 to 36 drives - 365GB to 36TB.
Note 2: Up to two expansion trays are supported.
Note 3: Drive depopulation scales from 5 to 12 disk drives per tray.
Interfaces
Host interfaces/link speeds Up to four 4 iSCSI 1Gb/s ports per array, up to 1GB cache per controller
Environment
Heat Output
460 watts (1,571 BTU/hr.)
AC Power 3.96 A Max Opertaing @ 115 VAC (90 - 136 VAC Range), 47/63 Hz
2.06 A Max Operating @ 240 VAC (180 - 264 VAC Range), 47/63 Hz
Temperature Operating: 10° C to 40° C (50° F to 104° F), without battery; 10° C to 35° C (50° F to 95° F), with battery
Non-Operating: -10° C to 50° C (-14° F to 122° F), without battery; -10° C to 45° C (-14° F to 113° F), with battery
Relative Humidity Operating: 20% to 80% relative humidity, noncondensing
Non-Operating: 10% to 90% relative humidity, noncondensing, max dew point is 26° C (79° F), 10 percent per hour gradient.
Altitude Operating: 68.3 kPa (3,200 m), 40° C, four-hour dwell
Non-Operating: 18.8 kPa (12,200 m), 0° C, four-hour dwell
Shock Operating: 5.5g's, 11 ms, half-sine, 10 shocks per direction, all 6 directions
Non-Operating: 20 G, 8.0 msec square wave in each direction along x,y and z axis. 33 Gs, 11msec, half-sine, three shocks per direction, all six directions
Vibration Operating: All three axes: 0.25 g's, 5 to 500 Hz, swept-sine, 5 sweep cycles, 1 octave per minute
Non-Operating: All three axes:1.2 Gs, five to 500 Hz, swept-sine, 5 sweep cycles, 1 octave per minute
Dimensions and Weights
Height 86.1 mm (3.39 in)
Width 448.6 mm (17.66 in)
Depth 540 mm (21.26 in)
Weight (maximum) 27.01 kg (59.55 lb) with 12 disks
Regulations
Note: Meets or exceeds the following requirements.
NEBS Support GR-63 CORE Requirements GR-1089 CORE Requirements Support AC and -48V DC power supply capability
Safety and Emissions EN55022 Report FCC (> 1 GHz), part 15, VCCI Class A, AS/NZS 3548, EN 61000-3-2, EN 61000-3-3, EN55024, EN300 386 (for Radiated Immunity only), RoHS, WEEE
Immunity CISPR 24 (EN55024), IEC 61000-4-2
Rack Mounting
Rack mountable in 19 inch-wide rack
Clearance and Service Access
Front 38 cm (15 in) for service access
15 cm (6 in) for cooling
Rear 38 cm (15 in) for service access
15 cm (6 in) for cooling
Airflow for cooling is from front to rear.

 


  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback