LED Name |
LED color |
Description |
7320 Locator LED and Locator button |
White |
Enables you to identify a particular server. The LED is controlled using one of the following methods:
- Issuing the setlocator on or off command
- Using the Solaris OS command: locator -n (to turn on) or -f (to turn off).
This LED provides the following indications:
- Off - Normal operating state.
- Fast Blink - The server received a signal as a result of one of the preceding methods and is indicating
here I am - and that it is operational.
|
7320 Service Action Required LED |
Amber |
The service required LED will illuminate when any of the following conditions occur:
- A fault is detected by the system diagnostics, such as POST
- When a FRU fails, such as a power supply
|
7320 Power/OK LED |
Off |
The system is unavailable. System power might be off or simply disconnected. |
Green - Steady On |
Normal Operating State |
Green - Slow Blink |
Indicates that the system is in SUSPEND mode. |
7320 Power on/off Button |
Turns the system on and off. This button is recessed to prevent accidental server power-off.
There is no Power On/Off button on the rear panel.
|
7320 Power Supply Service LED |
Amber |
The power supply is faulty. The front and rear panel Service Required LED
are also lit if the system detects a power supply fault.
|
7320 System Overtemperature LED |
Amber |
The system is over heating.
|
7320 Fan Module Service LED |
Amber |
The fan module is faulty. The front and rear panel Service required LEDs are
also lit if the system detects a fan module fault.
|
Disk Shelf 24x3.5" SAS-2 Locate Button/Indicator LED |
White - Off |
Not supported.
|
White - Blinking @ 1 Hz 50% |
Locate LED is active. |
Disk Shelf 24x3.5" SAS-2 System Fault Indicator LED |
Green - Steady On |
System is powered on. |
Green - Blinking @ 4 Hz 50% |
System is booting or being configured. |
Green - Off |
System is powered off. |
Amber - Off |
No current faults. |
Amber - On |
System fault. |
Disk Shelf 24x3.5" SAS-2 System Power Indicator |
Green |
System powered on and functioning.
|
Disk Shelf 24x3.5" SAS-2 System Overtemp Indicator LED |
Amber - On |
System is over heating.
|
Disk Shelf 24x3.5" SAS-2 SIMM Board Fault Indicator LED |
Amber - On |
SIMM Board failure.
|
Disk Shelf 24x3.5" SAS-2 Power Supply Fault Indicator LED |
Amber |
Power Supply failure..
|
LED Name |
Description |
Disk Shelf 24x3.5" SAS-2 AC power status Indicator |
Green - On : AC power ready. |
Disk Shelf 24x3.5" SAS-2 DC power status Indicator |
Green - On : DC power ready |
Disk Shelf 24x3.5" SAS-2 Cooling Fan Status Indicator |
Amber - On : Fan failure |
Disk Shelf 24x3.5" SAS-2 Power supply status Indicator |
Amber - On : Power supply failure |
Disk Shelf 24x3.5" SAS-2 Port OK Indicator |
Green - On: Normal operation. |
Disk Shelf 24x3.5" SAS-2 Port Fault Indicator |
Amber - On: Fault condition detected. |
Disk Shelf 24x3.5" SAS-2 SIM Board Locator Indicator |
Amber - On: SIM Board failure |
Disk Shelf 24x3.5" SAS-2 SIM Board OK Indicator |
Green - On: System functioning properly |
7320 Locator LED/ Locator button |
Reference Front Panel Locator LED/button listed above |
7320 Service Action Required LED |
Reference Front Panel Service Required LED listed above |
7320 Power/OK LED |
Reference Front Panel Power OK LED listed above |