Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



Sun Fire X4450

375-3510 540-7381
System Board
Assembly/FRU
System Board + Tray

Jumpers

LOCATION PINS SETTING DESCRIPTION
J33 1-3
2-4
In
In
Clear NVRAM (temporary setting)
Clear Password (temporary setting)
J16 1-2 Out BMC Disable (default)
J40 1-2 Out Unknown

Sun Fire X4450 Codename: Tucani

Notes

  1. The minimum Solaris operating system is Solaris 10 8/07.
  2. System Board 375-3510 details are not available in a Bill of Materials.
  3. Heatsink 310-0160 is pregreased with Shin-Etsu X23-7783D.
  4. The System Board FRU includes a mounting tray, four 250-1802 Cleaning Wipes, and four 310-0065 Thermal Grease Syringes.
  5. A two-CPU configuration utilizes CPU0 and CPU1.

Firmware Notes

  1. MAXII CPLD code at U107 does not have a Sun part number.
  2. BIOS code at U44 does not have a Sun part number.
  3. System Board 540-7381-01 with ELOM changed to 540-7381-02 with ILOM in August 2008. (WO_39580)

Memory Notes

  1. Install memory in matched pairs.
  2. Memory FRUs include two matched DIMMs.
  3. Sun Fire X4450 DIMMs are not labeled with the FRU part number.
  4. Install the largest capacity memory in the lowest numbered slots.
  5. Install the first DIMM pair in slots A0/B0. Install the second pair in slots C0/D0.
  6. Install additional memory in slots A1/B1, C1/D1, A2/B2, C2/D2, A3/B3, C3/D3, A4/B4, C4/D4, A5/B5, C5/D5, A6/B6, C6/D6, A7/B7, and C7/D7.
  7. A 3mm allen wrench is required to remove the Memory Riser cap-head screws.

References

  1. Sun Fire X4450 Server Product Notes, 820-2703.
  2. Sun Fire X4450 Server Service Manual, 820-2707.
  3. Sun Fire X4450 Server Installation Guide, 820-2709.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback