Ultra 27 (B27)
Jumper and Switch Settings
JUMPER |
PINS |
SETTING |
DESCRIPTION |
J8 |
3 |
1-2 2-3 |
IEEE 1394 disable
IEEE 1394 enable (default) |
J24 |
3 |
1-2 2-3 |
Normal CMOS (default)
Clear CMOS (temporary setting) |
SW1 |
n/a |
n/a |
Power Button |
SW2 |
n/a |
n/a |
Reset Button |
Ultra 27 Codename: Volans |
Notes
- The minimum Solaris operating system is Solaris 10 10/08 x64.
- Battery FRU 371-2210 is a Maxell, Panasonic, or Renata CR2032.
- The battery installed by the external manufacturer is a Mitsubishi CR2032.
- Nine screws fasten the system board to the chassis.
- Heatsink 310-0258 is pre-greased with Shin-Etsu X23-7783D.
- The System Board FRU includes one 310-0065 Shin-Etsu X23-7783D syringe.
Memory Installation Notes
- The minimum configuration is a single 1GB DIMM in Slot 1.
- A single 2GB DIMM configuration is not supported.
- A medium configuration is a DIMM in Slot 1, Slot 3, and Slot 5.
- The maximum configuration is a DIMM in all six slots.
References
-
Sun Ultra 27 Workstation Installation Guide, 820-6771.
-
Sun Ultra 27 Workstation Product Notes, 820-6774.
-
Sun Ultra 27 Workstation Service Manual, 820-6776.
|