Ultra 1 Model 200E

A12-200E / Netra i 1/200E

501-4134 501-4358 501-5403
200MHz 0MB FRU
FAB 270-4134
200MHz 0MB FRU
FAB 270-4358
200MHz 0MB FRU
FAB 270-4358

Backpanel and Connectors

Jumper Settings

JUMPER PINS SETTING DESCRIPTION
J2002 1-2
2-3
In
In
Select FPROM (default)
Select ROMBO
J2003 1-2
2-3
In
In
FPROM write protect (default)
FPROM write enable
J2102 1-24 Out Serial port connector
J2103 1-8 Out Serial port edge test
J2104 1-2
2-3
In
In
RS-232 -12Vdc
RS-423 (default)
J2105 1-2
2-3
In
In
RS-232 +12Vdc
RS-423 (default)
J2201 1-2
2-3
Out
Out
Button XIR
Button POR
J2202 1-8 Out ROMBO connector
J2203 1-8 Out JTAG connector
J2204 1-2
2-3
In
In
FPROM high half booting
FPROM low half booting (default)
J3603 1-8 Out Ethernet edge test

Configured System Boards

PART
NUMBER
MEMORY
SIZE
SIMM
SIZE
NUMBER
SIMMs
501-4144 64MB 32MB 2
501-4145 256MB 128MB 2
501-4244 128MB 64MB 2
501-4380 512MB 128MB 4

Notes

  1. The minimum operating system is Solaris 2.5.1.
  2. The flash PROM is soldered to the system board.
  3. Use the Flash PROM Programming Utility to update the flash PROM.
  4. UltraSPARC Fan 540-2761 was replaced by Heatsink 540-3361 and Shield 540-3090 in May/June 1997.

References

  1. Sun Ultra 1 Series Installation Guide, 802-3825.
  2. Sun Ultra 1 Creator Series Service Manual, 802-4148.
  3. Flash PROM Programming Guide, 802-3233.