Ultra 1 Model 140
A11-140 / Netra i 1/140 / Netra j 1/145
501-2836 |
501-2854 |
501-2855 |
501-2994 |
143MHz 0MB FRU |
143MHz 32MB |
143MHz 128MB |
143MHz 64MB |
Backpanel and Connectors
FAB 270-2836-02 Jumper Settings
JUMPER |
PINS |
SETTING |
DESCRIPTION |
J1101 |
1-2 2-3 |
Out N/A |
Pins 2-3 are hardwired |
J1102 |
1-2 2-3 |
Out N/A |
Pins 2-3 are hardwired |
J1405 |
1-3 |
- |
Pre-FCS speed selection |
J1406 |
1-3 |
- |
Pre-FCS speed selection |
J1407 |
1-3 |
- |
Pre-FCS speed selection |
J2002 |
1-2 2-3 |
In In |
Select FPROM (default)
Select ROMBO |
J2003 |
1-2 2-3 |
In In |
FPROM write protect (default)
FPROM write enable |
J2102 |
1-24 |
Out |
Serial port connector |
J2104 |
1-2 2-3 |
In In |
RS-232 -12Vdc
RS-423 (default) |
J2105 |
1-2 2-3 |
In In |
RS-232 +12Vdc
RS-423 (default) |
J2201 |
1-2 2-3 |
Out Out |
Button XIR
Button POR |
J2204 |
1-2 2-3 |
In In |
FPROM high half booting
FPROM low half booting (default) |
J1104 |
1-8 |
Out |
Ethernet edge test
|
J2103 |
1-8 |
Out |
Serial port edge test |
J2202 |
1-8 |
Out |
ROMBO connector
|
J2203 |
1-8 |
Out |
JTAG connector |
Notes
- The minimum operating system is Solaris 2.5.
- The flash PROM is soldered to the system board.
- Use the Flash PROM Programming Utility to update the flash PROM.
- UltraSPARC Fan 540-2761 was replaced by Heatsink 540-3361 and
Shield 540-3090 in May/June 1997.
References
-
Sun Ultra 1 Series Installation Guide, 802-3825.
-
Sun Ultra 1 Series Service Manual, 802-3819.
-
Flash PROM Programming Guide, 802-3233.
A11-140 / Netra i 1/140 / Netra j 1/145
501-2836 |
501-2854 |
501-2855 |
501-2994 |
143MHz 0MB FRU |
143MHz 32MB |
143MHz 128MB |
143MHz 64MB |
Backpanel and Connectors
FAB 270-2836-06 Jumper Settings
JUMPER |
PINS |
SETTING |
DESCRIPTION |
J1101 |
1-2 2-3 |
Out N/A |
Pins 2-3 are hardwired |
J1102 |
1-2 2-3 |
Out N/A |
Pins 2-3 are hardwired |
J2002 |
1-2 2-3 |
In In |
Select FPROM (default)
Select ROMBO |
J2003 |
1-2 2-3 |
In In |
FPROM write protect (default)
FPROM write enable |
J2102 |
1-24 |
Out |
Serial port connector |
J2104 |
1-2 2-3 |
In In |
RS-232 -12Vdc
RS-423 (default) |
J2105 |
1-2 2-3 |
In In |
RS-232 +12Vdc
RS-423 (default) |
J2201 |
1-2 2-3 |
Out Out |
Button XIR
Button POR |
J2204 |
1-2 2-3 |
In In |
FPROM high half booting
FPROM low half booting (default) |
J1104 |
1-8 |
Out |
Ethernet edge test |
J2103 |
1-8 |
Out |
Serial port edge test |
J2203 |
1-8 |
Out |
JTAG connector |
Notes
- The minimum operating system is Solaris 2.5.
- The flash PROM is soldered to the system board.
- Use the Flash PROM Programming Utility to update the flash PROM.
- UltraSPARC Fan 540-2761 was replaced by Heatsink 540-3361 and
Shield 540-3090 in May/June 1997.
References
-
Sun Ultra 1 Series Installation Guide, 802-3825.
-
Sun Ultra 1 Series Service Manual, 802-3819.
-
Flash PROM Programming Guide, 802-3233.
|