Disk Arrays: |
Storage 7210 |
Servers: |
Sun Fire X4540 |
501-7818 |
541-0491 |
541-3758 |
CPU/Memory Board w/o CPU or Memory L |
System Controller FRU CPU/Memory + I/O w/o CPU or Memory
L |
System Controller FRU CPU/Memory + I/O w/o CPU or Memory
L |
541-1219 |
541-3241 |
32GB System Controller 2x Opteron 2356 16x 2GB 371-1338
L |
64GB System Controller 2x Opteron 2356 16x 4GB 371-2956
L |
541-3750 |
541-3751 |
32GB System Controller 2x Opteron 2384 16x 2GB 371-4180
L X4540 only |
64GB System Controller 2x Opteron 2384 16x 4GB 371-2956
L X4540 only |
Sun Fire X4540 Codename: Thor
Storage 7210 Codename: Fugu |
Notes
- The minimum Solaris operating system is Solaris 10 5/08.
- DIMM pairs require matching characteristics including manufacturer, size,
and speed.
- Replace faulty DIMMs as a pair. The DIMM FRU includes two matching DIMMs.
- Fault Remind Button SW1 lights the CPU/Memory fault LEDs for up to
one minute.
X4540 Notes
- F541-0491 and F541-3758 do not include Heatsinks or Processors.
- F541-0491 and F541-3758 include one Alcohol Wipe and
one 310-0049 Thermal Grease Syringe.
- Assembly 541-0491 only supports Opteron 2356 (Barcelona).
- Assembly 541-0491 does not support Opteron 2384 (Shanghai).
- Assembly 541-3758 supports Opteron 2356 (Barcelona) and 2384 (Shanghai).
- Assembly 541-3758 includes I/O Board 501-7819-07 with BIOS and ILOM changes
required to support Opteron 2384 (Shanghai).
(WO_40451)
- Assembly 541-3758 includes CPU/Memory Board 501-7818-04 with capacitor
changes required to support Opteron 2384 (Shanghai).
(WO_40146)
- Compact Flash Filler 343-1135 was added to the System Controller in
August 2010 to reduce radiated emissions.
(WO_43587)
7210 Notes
- F541-0491 does not include Heatsinks or Processors.
- F541-0491 includes one Alcohol Wipe and one 310-0049 Thermal Grease Syringe.
- Assembly 541-0491 only supports Opteron 2356 (Barcelona).
- Assembly 541-0491 does not support Opteron 2384 (Shanghai).
References
-
Sun Fire X4500/X4540 Server Service Manual, 819-4359.
-
Sun Fire X4500/X4540 Server Administration Guide, 819-6562.
-
Sun Fire X4500/X4540 Server Installation Guide, 820-4855.
-
Sun Fire X4540 Server Product Notes, 820-4869.
-
Sun Fire X4500/X4540 Server Integrated Lights Out Manager (ILOM) Supplement, 819-4361.
-
Sun Fire X4500-to-X4540 Migration User's Guide, 820-6559.
-
Sun Storage 7210 Unified Storage System Installation Guide, 820-3757.
-
Sun Storage 7210 Unified Storage System Service Manual, 820-4160.
|