Sun Fire X2270
375-3602 |
System Board ASSY 411779700001
MAC 00144Fxxxxxx
|
Headers, Jumpers, and Switches
JUMPER |
PINS |
SETTING |
DESCRIPTION |
J2 |
1-2 |
In |
Normal CMOS (default) |
J2 |
2-3 |
In |
Clear CMOS (temporary setting only) |
J11 |
3 |
Out |
Not documented |
J12 |
2 |
Out |
Not documented |
J13 |
10 |
Out |
Not documented |
J14 |
8 |
Out |
Not documented |
J16 |
3 |
Out |
Not documented |
J17 |
1-2 |
In |
Normal Password (default) |
J17 |
2-3 |
In |
Clear Password (temporary setting only) |
J27 |
2 |
Out |
Not documented |
J30 |
2 |
Out |
Not documented |
J32 |
2 |
Out |
Not documented |
J33 |
2 |
Out |
Not documented |
J35 |
1-2 |
In |
Not documented |
J42 |
2-3 |
In |
Not documented |
J43 |
2-3 |
In |
Not documented |
J47 |
8 |
Out |
Not documented |
SW1 |
n/a |
n/a |
Locate Button |
SW2 |
n/a |
n/a |
Not documented |
SW3 |
n/a |
n/a |
Not documented |
SW4 |
n/a |
n/a |
Not documented |
Sun Fire X2270 Codename: Wasp |
Notes
- The minimum Solaris operating system is Solaris 10 10/08.
System Board Notes
- Battery FRU 371-2210 is a Maxell, Panasonic, or Renata CR2032.
- The battery installed by the external manufacture is a Mitsubishi CR2032.
- Heatsink 310-0239 is pre-greased with Shin-Etsu X23-7783D.
- Heatsink 310-0239 includes four Screws and four Springs with no part numbers.
- The System Board FRU includes two 250-1802 Cleaning Wipes, and two 310-0065
Shin-Etsu X23-7783D Thermal Grease Syringes.
Memory Installation Notes
- Do not install DIMMs in slots next to an empty CPU socket.
- Install the same number of identical DIMMs across all CPU sockets.
- Install Blue socket DIMMs D5/D3/D1 then install Black socket DIMMs D4/D2/D0.
- Use of the same DIMM size and speed is recommended for maximum performance.
References
-
Sun Fire X2270 Installation Guide, 820-5604.
-
Sun Fire X2270 Service Manual, 820-5607.
-
Sun Fire X2270 Product Notes, 820-5608.
|