Sun Fire V250
375-3105 |
375-3146 |
375-3147 |
375-3176 |
375-3130 |
w/o Memory w/o V250 Tray w/o USIIIi |
0MB FRU w/ V250 Tray 1× 1.064GHz |
0MB FRU w/ V250 Tray 2× 1.064GHz |
0MB FRU w/ V250 Tray 1× 1.28GHz |
0MB FRU w/ V250 Tray 2× 1.28GHz |
PCI Slot Numbering
SLOT |
BUS |
DEVICE TREE |
5 |
2B |
pci@1f,70000/*@2,* |
4 |
2A |
pci@1e,60000/*@2,* |
3 |
1A |
pci@1c,60000/*@2,* |
2 |
1B |
pci@1d,70000/*@2,* |
1 |
2A |
pci@1e,60000/*@3,* |
0 |
2A |
pci@1e,60000/*@4,* |
Jumper Settings
LOCATION |
PINS |
SETTING |
DESCRIPTION |
J9 |
1-8 |
Out |
Unknown |
J10 |
1-3 |
Out |
Unknown |
J11 |
1-46 |
n/a |
X86 Debug Header |
J12 |
1-8 |
Out |
JTAG Header |
J14 |
50 |
n/a |
Unused 50-Pin Header |
J16 |
3 |
n/a |
Speaker Header (not used) |
J19 |
3 |
n/a |
Glow Logo Header (not used) |
JP1 |
1-2 7-8 9-10 |
In In In |
CPU1 1.4V Core VID[4:0] Bit 0 (00110)
CPU1 1.4V Core VID[4:0] Bit 3 (00110)
CPU1 1.4V Core VID[4:0] Bit 4 (00110) |
JP2 |
1-2 7-8 9-10 |
In In In |
CPU0 1.4V Core VID[4:0] Bit 0 (00110)
CPU0 1.4V Core VID[4:0] Bit 3 (00110)
CPU0 1.4V Core VID[4:0] Bit 4 (00110) |
JP3 |
1-2 3-4 5-6 |
Out In Out |
1.280GHz CONFIG[2:0] Bit 0 (101)
1.280GHz CONFIG[2:0] Bit 1 (101)
1.280GHz CONFIG[2:0] Bit 2 (101) |
JP3 |
1-2 3-4 5-6 |
In In Out |
1.064GHz CONFIG[2:0] Bit 0 (100)
1.064GHz CONFIG[2:0] Bit 1 (100)
1.064GHz CONFIG[2:0] Bit 2 (100) |
JP4 |
1-8 |
Out |
Unknown |
JP5 |
1-2 2-3 |
In In |
FPROM low half booting (default)
FPROM high half booting (flash recovery) |
JP6 |
1-2 |
Out |
Clear CMOS when installed |
JP7 |
1-2 1-2 |
In Out |
FPROM write enabled (default)
FPROM write protected |
Sun Fire V250 Codename: Enchilada 2P Tower |
Notes
- The minimum operating system is Solaris 8 7/03 or Solaris 9 8/03.
Memory Notes
- Bank, Rank, DIMM, and XOR Interleaving is supported.
- UltraSPARC IIIi supports single bank and dual bank DDR DIMMs.
- Two DIMMs of the same bank size (single or dual) and memory size form a
bank.
- The minimum requirement is two DIMMs per CPU
(DIMM 0/1 or 2/3, and 4/5 or 6/7).
- Only CPU 0 DIMMs are accessible in a single CPU system (CPU 0).
- Memory is mapped globally and is accessible by either CPU in a dual-CPU
system.
- Memory error reporting identifies a failing Bank, not a single failing DIMM.
References
-
Sun Fire V250 Server Installation Guide, 817-0899.
-
Sun Fire V250 Server Administration Guide, 817-0900.
-
Sun Fire V250 Server Parts Replacement Manual, 817-0901.
- Sun Fire V250 ALOM Beta Online Help, 817-3175.