Sun Fire V20z
501-6840 |
Newisys S01357 / S00401 / S00189 / S00190
370-6730 w/o BIOS
A55A-AA Chassis FRU 380-0979
A55B-AA Chassis FRU 380-0979
MAC Address 00093dxxxxxx |
Jumpers
LOCATION |
PINS |
SETTING |
DESCRIPTION |
J19 |
1-2 1-2 |
Out In |
Port A is Port A (default)
Port A is Service Processor Console |
J108 |
2-3 2-3 |
In Out |
Net Power Usage Indicator enabled (default)
Net Power Usage Indicator disabled |
J110 |
1-2 2-3 |
In In |
Clear CMOS on next boot
Normal CMOS Operation (default) |
JP11 * |
1-2 1-2 |
In Out |
BIOS Main Body Write Enabled (default)
BIOS Main Body Write controlled by BIOS or SP |
JP12 * |
1-2 1-2 |
In Out |
BIOS Boot Block Write Enabled (default)
BIOS Boot Block Write controlled by SP |
* Leave JP11 and JP12 in the default position.
HyperTransport/PCI Interrupt Map
HT/PCI BRIDGE |
DEVICE |
IRQ A |
IRQ B |
IRQ C |
IRQ D |
AMD-8131 Golem 0-B |
PCI Slot 2 |
x |
x |
x |
x |
AMD-8131 Golem 0-A |
BCM5703 Ethernet 0 |
|
x |
|
|
AMD-8131 Golem 0-A |
BCM5703 Ethernet 1 |
|
|
x |
|
AMD-8131 Golem 0-A |
53C1020 SCSI |
|
|
|
x |
AMD-8131 Golem 0-A |
PCI Slot 1 |
x |
x |
x |
x |
Installing a 33MHz card in Slot 1 forces Bus A to operate at 33MHz and
affects performance of the BCM5703 Ethernet controllers.
LEDs
LOCATION |
COLOR |
STATE |
DESCRIPTION |
D8 |
Amber |
Fault |
CPU0 Status |
D10 |
Amber |
Fault |
CPU0 Memory VRM Status |
D11 |
Amber |
Fault |
DVD Status |
D12-15 |
Amber |
Fault |
CPU0 DIMM 0-3 Status |
D16 |
Amber |
Fault |
CPU1 Status |
D18 |
Amber |
Fault |
CPU1 Memory VRM Status |
D19 |
Amber |
Fault |
Floppy Status |
D20-23 |
Amber |
Fault |
CPU1 DIMM 0-3 Status |
D26 |
Amber |
Fault |
PCI Slot 1 Status |
D27 |
Amber |
Fault |
PCI Slot 2 Status |
D32 |
Red |
Error |
Fan at full speed |
D34 |
Yellow |
Normal |
Gigabit Ethernet 0 Mode |
D35 |
Yellow |
Normal |
Gigabit Ethernet 0 Link |
D36 |
Yellow |
Normal |
Gigabit Ethernet 1 Mode |
D37 |
Yellow |
Normal |
Gigabit Ethernet 1 Link |
D46 |
Red |
Normal |
Service Processor Status |
D47 |
Red |
Unknown |
Service Processor Status |
D48 |
Red |
Normal |
Service Processor Status |
D53 |
Green |
Normal |
Power Supply POWER OK |
D54 |
Green |
Normal |
Power On Indicator |
D55 |
Yellow |
Reset |
Reset Indicator |
D56 |
Red |
Normal |
Ethernet Connected to Upper MGMT Port |
D57 |
Red |
Normal |
Ethernet Connected to Lower MGMT Port |
D59 |
Green |
Normal |
AMD-8111 RAM Power On |
D60 |
Green |
Normal |
CPU0 VRM Power OK |
D63 |
Green |
Normal |
CPU1 VRM Power OK |
D66 |
Green |
Normal |
AMD-8111 Power OK |
D67 |
Red Red |
Error Reset |
Power Reset Sequencer Internal Error
SW1 Service Processor Reset Pressed |
D79 |
Green |
Normal |
53C1020 SCSI Channel A Indicator |
D81 |
Green |
Normal |
53C1020 SCSI Controller Operational |
Notes:
The normal state of D46 and D48 is an illuminated Red LED.
The normal state of D56 is a illuminated Red LED when a cable is connected.
The normal state of D57 is a illuminated Red LED when a cable is connected.
|
Sun Fire V20z Codename: Stinger2P |
Notes
- The Sun Fire V20z System Board is not a Field Replaceable Unit.
- Press F2 during bootup to enter the BIOS menu.
- BIOS updates are available at
V20z SW 2.8.2 - Bundles.
- Due to AMD-8131 Errata 56, four-function PCI-X option cards are not
supported on the Sun Fire V20z.
See Release Notes
for details about Errata 56.
PCI Slot Notes
- The Slot 1 PCI Card Guide is installed on System Board 501-6840
near D36 and D37.
- The Slot 1 PCI Card Guide is not installed on System Board 501-7039.
- The Slot 1 PCI Card Guide limits the card length to approximately 172 mm.
- The Dual SCSI/Dual FastEthernet Option 2222 length is approximately 178 mm.
References
-
Sun Fire V20z and V40z Servers Release Notes, 819-1771.
-
Sun Fire V20z Server Installation Guide, 817-5246.
-
Sun Fire V20z Server User Guide, 817-5248.
-
Sun Fire V20z Server Management Guide, 817-5249.
-
Sun Fire V20z and V40z Servers Troubleshooting Techniques and Diagnostics Guide, 817-7184.
Sun Fire V20z
501-7039 |
Newisys S02398 / S02035 / S02009
370-7691 w/o BIOS
A55D-AA Chassis FRU 380-1168
MAC Address 00093dxxxxxx |
Jumpers
LOCATION |
PINS |
SETTING |
DESCRIPTION |
J19 |
1-2 1-2 |
Out In |
Port A is Port A (default)
Port A is Service Processor Console |
J108 |
2-3 2-3 |
In Out |
Net Power Usage Indicator enabled (default)
Net Power Usage Indicator disabled |
J110 |
1-2 2-3 |
In In |
Clear CMOS on next boot
Normal CMOS Operation (default) |
JP11 * |
1-2 1-2 |
In Out |
BIOS Main Body Write Enabled (default)
BIOS Main Body Write controlled by BIOS or SP |
JP12 * |
1-2 1-2 |
In Out |
BIOS Boot Block Write Enabled (default)
BIOS Boot Block Write controlled by SP |
* Leave JP11 and JP12 in the default position.
HyperTransport/PCI Interrupt Map
HT/PCI BRIDGE |
DEVICE |
IRQ A |
IRQ B |
IRQ C |
IRQ D |
AMD-8131 Golem 0-B |
PCI Slot 2 |
x |
x |
x |
x |
AMD-8131 Golem 0-A |
BCM5704 Ethernet 0 |
|
x |
|
|
AMD-8131 Golem 0-A |
BCM5704 Ethernet 1 |
|
|
x |
|
AMD-8131 Golem 0-A |
53C1020 SCSI |
|
|
|
x |
AMD-8131 Golem 0-A |
PCI Slot 1 |
x |
x |
x |
x |
Installing a 33MHz card in Slot 1 forces Bus A to operate at 33MHz and
affects performance of the BCM5703 Ethernet controllers.
LEDs
LOCATION |
COLOR |
STATE |
DESCRIPTION |
D8 |
Amber |
Fault |
CPU0 Status |
D10 |
Amber |
Fault |
CPU0 Memory VRM Status |
D11 |
Amber |
Fault |
DVD Status |
D12-15 |
Amber |
Fault |
CPU0 DIMM 0-3 Status |
D16 |
Amber |
Fault |
CPU1 Status |
D18 |
Amber |
Fault |
CPU1 Memory VRM Status |
D19 |
Amber |
Fault |
Floppy Status |
D20-23 |
Amber |
Fault |
CPU1 DIMM 0-3 Status |
D26 |
Amber |
Fault |
PCI Slot 1 Status |
D27 |
Amber |
Fault |
PCI Slot 2 Status |
D32 |
Red |
Error |
Fan at full speed |
D34 |
Yellow |
Normal |
Gigabit Ethernet 0 Mode |
D35 |
Yellow |
Normal |
Gigabit Ethernet 0 Link |
D36 |
Yellow |
Normal |
Gigabit Ethernet 1 Mode |
D37 |
Yellow |
Normal |
Gigabit Ethernet 1 Link |
D46 |
Red |
Normal |
Service Processor Status |
D47 |
Red |
Unknown |
Service Processor Status |
D48 |
Red |
Normal |
Service Processor Status |
D53 |
Green |
Normal |
Power Supply POWER OK |
D54 |
Green |
Normal |
Power On Indicator |
D55 |
Yellow |
Reset |
Reset Indicator |
D56 |
Red |
Normal |
Ethernet Connected to Upper MGMT Port |
D57 |
Red |
Normal |
Ethernet Connected to Lower MGMT Port |
D59 |
Green |
Normal |
AMD-8111 RAM Power On |
D60 |
Green |
Normal |
CPU0 VRM Power OK |
D63 |
Green |
Normal |
CPU1 VRM Power OK |
D66 |
Green |
Normal |
AMD-8111 Power OK |
D67 |
Red Red |
Error Reset |
Power Reset Sequencer Internal Error
SW1 Service Processor Reset Pressed |
D79 |
Green |
Normal |
53C1020 SCSI Channel A Indicator |
D81 |
Green |
Normal |
53C1020 SCSI Controller Operational |
Notes:
The normal state of D46 and D48 is an illuminated Red LED.
The normal state of D56 is a illuminated Red LED when a cable is connected.
The normal state of D57 is a illuminated Red LED when a cable is connected.
|
Sun Fire V20z Codename: Stinger2P |
Notes
- The Sun Fire V20z System Board is not a Field Replaceable Unit.
- Press F2 during bootup to enter the BIOS menu.
- BIOS updates are available at
V20z SW 2.8.2 - Bundles.
- Due to AMD-8131 Errata 56, four-function PCI-X option cards are not
supported on the Sun Fire V20z.
See Release Notes
for details about Errata 56.
- The BCM5704 Ethernet Controller on System Board 501-7039 requires an
Install-Time Update (ITU) to install Solaris 9 4/04 x86 or
Solaris 9 9/04 x86.
Refer to FIN I1154.
- System Board 501-7039 is installed in Chassis FRU 380-1168.
PCI Slot Notes
- The Slot 1 PCI Card Guide is installed on System Board 501-6840
near D36 and D37.
- The Slot 1 PCI Card Guide is not installed on System Board 501-7039 or
501-7125.
- The Slot 1 PCI Card Guide limits the card length to approximately 172 mm.
- The Dual SCSI/Dual FastEthernet Option 2222 length is approximately 178 mm.
References
-
Sun Fire V20z and V40z Servers Release Notes, 819-1771.
-
Sun Fire V20z Server Installation Guide, 817-5246.
-
Sun Fire V20z Server User Guide, 817-5248.
-
Sun Fire V20z Server Management Guide, 817-5249.
-
Sun Fire V20z and V40z Servers Troubleshooting Techniques and Diagnostics Guide, 817-7184.
Sun Fire V20z
501-7125 |
Newisys S02595 / S02615
370-7788 w/o BIOS
A55E-AA Chassis FRU 380-1194
MAC Address 00093dxxxxxx |
Jumpers
LOCATION |
PINS |
SETTING |
DESCRIPTION |
J19 |
1-2 1-2 |
Out In |
Port A is Port A (default)
Port A is Service Processor Console |
J108 |
2-3 2-3 |
In Out |
Net Power Usage Indicator enabled (default)
Net Power Usage Indicator disabled |
J110 |
1-2 2-3 |
In In |
Clear CMOS on next boot
Normal CMOS Operation (default) |
JP11 * |
1-2 1-2 |
In Out |
BIOS Main Body Write Enabled (default)
BIOS Main Body Write controlled by BIOS or SP |
JP12 * |
1-2 1-2 |
In Out |
BIOS Boot Block Write Enabled (default)
BIOS Boot Block Write controlled by SP |
* Leave JP11 and JP12 in the default position.
HyperTransport/PCI Interrupt Map
HT/PCI BRIDGE |
DEVICE |
IRQ A |
IRQ B |
IRQ C |
IRQ D |
AMD-8131 Golem 0-B |
PCI Slot 2 |
x |
x |
x |
x |
AMD-8131 Golem 0-A |
BCM5704 Ethernet 0 |
|
x |
|
|
AMD-8131 Golem 0-A |
BCM5704 Ethernet 1 |
|
|
x |
|
AMD-8131 Golem 0-A |
53C1020 SCSI |
|
|
|
x |
AMD-8131 Golem 0-A |
PCI Slot 1 |
x |
x |
x |
x |
Installing a 33MHz card in Slot 1 forces Bus A to operate at 33MHz and
affects performance of the BCM5703 Ethernet controllers.
LEDs
LOCATION |
COLOR |
STATE |
DESCRIPTION |
D8 |
Amber |
Fault |
CPU0 Status |
D10 |
Amber |
Fault |
CPU0 Memory VRM Status |
D11 |
Amber |
Fault |
DVD Status |
D12-15 |
Amber |
Fault |
CPU0 DIMM 0-3 Status |
D16 |
Amber |
Fault |
CPU1 Status |
D18 |
Amber |
Fault |
CPU1 Memory VRM Status |
D19 |
Amber |
Fault |
Floppy Status |
D20-23 |
Amber |
Fault |
CPU1 DIMM 0-3 Status |
D26 |
Amber |
Fault |
PCI Slot 1 Status |
D27 |
Amber |
Fault |
PCI Slot 2 Status |
D32 |
Red |
Error |
Fan at full speed |
D34 |
Yellow |
Normal |
Gigabit Ethernet 0 Mode |
D35 |
Yellow |
Normal |
Gigabit Ethernet 0 Link |
D36 |
Yellow |
Normal |
Gigabit Ethernet 1 Mode |
D37 |
Yellow |
Normal |
Gigabit Ethernet 1 Link |
D46 |
Red |
Normal |
Service Processor Status |
D47 |
Red |
Unknown |
Service Processor Status |
D48 |
Red |
Normal |
Service Processor Status |
D53 |
Green |
Normal |
Power Supply POWER OK |
D54 |
Green |
Normal |
Power On Indicator |
D55 |
Yellow |
Reset |
Reset Indicator |
D56 |
Red |
Normal |
Ethernet Connected to Upper MGMT Port |
D57 |
Red |
Normal |
Ethernet Connected to Lower MGMT Port |
D59 |
Green |
Normal |
AMD-8111 RAM Power On |
D60 |
Green |
Normal |
CPU0 VRM Power OK |
D63 |
Green |
Normal |
CPU1 VRM Power OK |
D66 |
Green |
Normal |
AMD-8111 Power OK |
D67 |
Red Red |
Error Reset |
Power Reset Sequencer Internal Error
SW1 Service Processor Reset Pressed |
D79 |
Green |
Normal |
53C1020 SCSI Channel A Indicator |
D81 |
Green |
Normal |
53C1020 SCSI Controller Operational |
Notes:
The normal state of D46 and D48 is an illuminated Red LED.
The normal state of D56 is a illuminated Red LED when a cable is connected.
The normal state of D57 is a illuminated Red LED when a cable is connected.
|
Sun Fire V20z Codename: Stinger2P |
Notes
- The Sun Fire V20z System Board is not a Field Replaceable Unit.
- Press F2 during bootup to enter the BIOS menu.
- BIOS updates are available at
V20z SW 2.8.2 - Bundles.
- Due to AMD-8131 Errata 56, four-function PCI-X option cards are not
supported on the Sun Fire V20z.
See Release Notes
for details about Errata 56.
- The BCM5704 Ethernet Controller on System Board 501-7125 requires an
Install-Time Update (ITU) to install Solaris 9 4/04 x86 or
Solaris 9 9/04 x86.
Refer to FIN I1154.
- System Board 501-7125 is installed in Chassis FRU 380-1194.
PCI Slot Notes
- The Slot 1 PCI Card Guide is installed on System Board 501-6840
near D36 and D37.
- The Slot 1 PCI Card Guide is not installed on System Board 501-7039 or
501-7125.
- The Slot 1 PCI Card Guide limits the card length to approximately 172 mm.
- The Dual SCSI/Dual FastEthernet Option 2222 length is approximately 178 mm.
References
-
Sun Fire V20z and V40z Servers Release Notes, 819-1771.
-
Sun Fire V20z Server Installation Guide, 817-5246.
-
Sun Fire V20z Server User Guide, 817-5248.
-
Sun Fire V20z Server Management Guide, 817-5249.
-
Sun Fire V20z and V40z Servers Troubleshooting Techniques and Diagnostics Guide, 817-7184.
|