Sun Fire V100
375-3090 |
375-3110 |
375-3115 |
0MB 500MHz UltraSPARC IIe |
0MB 550MHz UltraSPARC IIi |
0MB 650MHz UltraSPARC IIi |
Jumper Settings
JUMPER |
PINS |
SETTING |
DESCRIPTION |
JP1 |
1-2 1-2 |
In Out |
Registered DIMM Buffered mode (500MHz)
Registered DIMM Non-Buffered mode (550/650MHz) |
JP9 |
1-2 2-3 |
In In |
Select Flash PROM (default)
Select ROMBO |
JP13 |
1-2 1-2 |
Out In |
Normal LOM (default)
Reset LOM |
JP14 |
1-2 1-2 |
Out In |
Normal LOM operation (default)
LOM auto program on reset over Serial A |
JP15 |
1-2 1-2 |
Out In |
Normal RTC (default)
Reset RTC |
JP16 |
1-2 1-2 |
Out In |
Normal
Reset Southbridge |
JP18 |
1-2 1-2 |
Out In |
Normal Flash (default)
Flash write enable |
JP19 |
1-2 1-2 |
Out In |
Normal LOM (default)
Override LOM control of power supply |
JP7 Speed Select Jumper Settings
1-2 |
3-4 |
5-6 |
DESCRIPTION |
Part Number (Codename) |
In |
Out |
In |
500MHz UltraSPARC IIe |
100-7270 (Hummingbird) |
Out |
Out |
In |
550MHz UltraSPARC IIi |
100-7192 (Phantom) |
Out |
In |
Out |
650MHz UltraSPARC IIi |
527-1023 (Phantom) |
Sun Fire V100 Codename: Flapjack Lite CD500 |
Notes
- The minimum Sun Fire V100 operating system is Solaris 8 2/02.
- The hostid, MAC address, and OBP environment settings are stored
on System Configuration Smart Card 370-4285.
- The Sun Fire V100 System Board is based on the Netra X1 System Board
with updated OBP, LOMLITE2, and LOM EEPROM firmware.
- There is no Sun Fire V100 System Board FRU or UltraSPARC II FRU.
Memory Notes
- The memory installation sequence is Slot 3, 2, 1, and 0.
- Each DIMM slot addresses 512MB with <550MHz UltraSPARC IIe.
- Each DIMM slot addresses 1GB with >=550MHz UltraSPARC IIi.
- When equal size DIMMs are installed, the lowest slot number is
mapped to the lowest address range.
- When mixed size DIMMs are installed, the slot number with the
largest size DIMM is mapped to the lowest address range.
UltraSPARC IIi Notes
- The 650MHz UltraSPARC IIi is similar to the 270-440MHz UltraSPARC IIi.
Differences include integrated L2 Cache and SDRAM Memory Control.
- The 650MHz UltraSPARC IIi is based on the 500MHz UltraSPARC IIe.
- The 550-650MHz UltraSPARC IIi OBP and OS name is UltraSPARC IIe.
Reference
-
Sun Fire V100 Server User's Guide, 816-2756.
|