Sun Blade 1000/2000 / Sun Fire 280R / Netra 20
A28 / A29 / A35 / N28
501-4143 |
501-5938 |
501-6230 |
501-6560 |
501-6768 |
0MB FRU 270-4143-08 SB1000
August 2000 SCHIZO <=2.1 |
0MB FRU 270-4143-08 SB1000 SF280R/N20
November 2000 SCHIZO 2.2 |
0MB FRU 270-4143-11 SB1000/2000 SF280R/N20
December 2001 SCHIZO >=2.2 |
0MB FRU 270-6560-02 SB1000/2000 SF280R/N20
June 2003 SCHIZO 2.5 ELE 1.1 |
0MB 270-6768-01 SB2000 SF280R/N20
August 2004 SCHIZO 2.5 |
Jumper Settings
JUMPER |
PINS |
SETTING |
DESCRIPTION |
J2103 |
1-2 2-3 |
In In |
FPROM write protected
FPROM write enabled (default) |
J2104 |
1-2 2-3 |
Out In |
FPROM high half booting
FPROM low half booting (default) |
|
Miscellaneous Connectors
CONNECTOR |
PINS |
DESCRIPTION |
J1901 |
1-8 |
Serial test (factory use) |
J3301 |
1-2 |
DIMM Fan Power |
J3302 |
1-2 |
Graphics and PCI Fan Power |
J3303 |
1-2 |
CPU Fan Power |
J3601 |
1-28 |
Power supply +3.3V and +5V |
J3602 |
1-8 |
Interlock, LED, speaker, and power switch |
J3603 |
1-14 |
Power supply sense |
J3605 |
1-6 |
Glow Logo LED |
J3608 |
1-10 |
DC power to internal peripherals |
J4802 |
1-38 |
ROMBO (factory use) |
J4803 |
1-8 |
JSCC (factory use) |
J5201 |
1-2 |
Logic Analyzer Clock |
J5202 |
1-2 |
Logic Analyzer Clock |
Rear View
(Sun Blade 1000 Rear View shown)
PCI Slot Numbering
SLOT |
BUS |
DEVICE TREE |
4 |
B |
pci@8,700000/*@1,* |
3 |
B |
pci@8,700000/*@2,* |
2 |
B |
pci@8,700000/*@3,* |
1 |
A |
pci@8,600000/*@1,* |
PCI Bus A shares the address/data bus with the FC-AL device. PCI Bus B
shares the address/data bus with on-board Audio, Ethernet, Flash,
Floppy, IEEE 1394, Parallel, SCSI, Serial, and USB devices.
System Codenames
System |
Codename |
Sun Blade 1000 |
Excalibur |
Sun Fire 280R |
Littleneck |
Netra 20 |
Lightweight 2+ |
Notes
- The minimum Sun Blade 1000 operating system is Solaris 8 10/00.
- The minimum Sun Blade 2000 operating system is Solaris 8 2/02.
- The minimum Sun Fire 280R operating system is Solaris 8 1/01.
- The minimum Netra 20 operating system is Solaris 8 4/01.
- The system will not boot without a CPU module in Slot 0.
If only one CPU module is installed, it must be in Slot 0,
and Slot 1 should be covered with a CPU Shroud Cover.
- The minimum memory requirement is four DIMMs in any group.
- Each group addresses 4GB memory.
- Memory slots (Jxxxx) map to same-numbered DIMMs (Uxxxx):
Slot |
DIMM |
J0407 |
U0407 |
J0406 |
U0406 |
J0305 |
U0305 |
J0304 |
U0304 |
J0203 |
U0203 |
J0202 |
U0202 |
J0101 |
U0101 |
J0100 |
U0100 |
Compatibility Notes
- Sun Fire 280R is not compatible with 501-4143.
- Netra 20 was not tested with 501-4143.
- Netra 20 requires OBP 4.2 Version 4 and FIRE-I V1.2 (U2107).
- Netra 20 comes up as a Netra T4 with OBP 4.2 Version 4.
- Sun Blade 2000 is identified as Sun Blade 1000 with OBP 4.5v10.
- OBP 4.2v4 and FIRE-I V1.2 are on 501-5938-07 and 501-6230-01.
- SCHIZO 2.4 is installed on 187 501-6230-07 boards labeled DEV 24943.
- The Sun Fire 280R and Netra 20 are not compatible with 501-6230-07
(approximate ship dates = October 2002 to mid-February 2003).
- GigaSwift Ethernet <=501-5902-07 installed on 501-6230-07 requires
Solaris 8 Patch
>=111883-12
or Solaris 9 Patch
>=112817-04.
OBP Notes
- The PROM contains Sun Blade 1000 and Sun Fire 280R OBP images.
- Sun Fire 280R and Netra 20 share the same OBP image.
- Sun Fire 280R requires a Remote System Control (RSC).
- Sun Fire 280R OBP is enabled when RSC is probed.
- Sun Blade 1000 OBP is enabled when RSC or Alarm are not probed.
- Netra 20 requires an Alarm Module and a System Configuration Card.
- Netra 20 uses the System Configuration Card MAC address and Hostid.
- Netra 20 Power Distribution Board includes an lm80 device.
- Netra 20 probes for SCCR, lm80, then Alarm during power-up.
System Board 501-6560 Notes
- The 501-6560-02 was released in June 2003.
- The 501-6560-02 and -03 were not structured to any system
Bill Of Material.
- The 501-6560-04 replaced 501-6230-12 in the Sun Blade 2000, Sun Fire 280R,
and Netra 20 in December 2003.
Refer to ECO WO_28087.
- Systems labeled with deviation label WO_28321, WO_28444, WO_28557,
WO_28991 or WO_28993 shipped with System Board 501-6230 after December 2003.
- The 501-6560-05 uses ELE 1.1+ as the primary PCI-UPA Bridge component.
- The 501-6560-05 uses SCHIZO 2.5 as the alternate PCI-UPA Bridge component.
- Boards with deviation label WO_28227 were built with FAB 270-6560-01.
- The 501-6560-05 includes the 501-6230-11, -12, and -13 changes.
System Board 501-6768 Notes
- The 501-6768-02 was released in August 2004.
(ECO WO_28833)
- The 501-6768-02 was not released as a FRU.
- Sun Blade 2000, Sun Fire 280R, and Netra 20 systems with deviation label
WO_29719 shipped with System Board 501-6768 in August and September 2004.
UltraSPARC III Notes
- Mixing UltraSPARC III speeds in the Sun Blade 1000 is supported.
- Use torque tool 340-6091 or 340-6395 to install the UltraSPARC III.
Both are calibrated to 5.0 +/- 0.5 in/lbs (.565 Nm).
- The Sun Blade 1000/2000, Sun Fire 280R, and Netra 20 systems include
a torque tool.
UltraSPARC III Cu Notes
- Mixing UltraSPARC III Cu module speeds is not supported.
- Mixing UltraSPARC III and UltraSPARC III Cu modules is not supported.
- The 900MHz UltraSPARC III Cu requires OBP >=4.4 version 6.
- Support for 1GHz processors is in OBP 4.5 Version 10.
- The minimum recommended OBP for 1015/1050MHz is 4.5 Version 16.
References
-
Sun Blade 1000 Service Manual, 805-4496.
-
Sun Blade 1000 and Sun Blade 2000 Service Manual, 816-3217.
-
Sun Fire 280R Service Manual, 806-4807.
-
Netra 20 Installation and User's Guide, 806-7334.
-
Netra 20 Service and System Reference Manual, 806-7336.
|