Sun Blade X6450
375-3564 |
540-7595 |
X6450-AA |
System Board
|
System Board FRU 375-3564 + Tray
w/o Processors w/o Heatsinks
|
X6450 Base 599-3506 w/o Processors
w/o Heatsinks
|
594-5397 |
594-5398 |
594-5399 |
594-5400 |
X6450-44L1860-82 16GB 2.93GHz 4x Xeon E7220
|
X6450-44M2130-82 16GB 1.86GHz 4x Xeon L7345
|
X6450-44M2400-B2 16GB 2.13GHz 4x Xeon E7320
|
X6450-42M2930-82 32GB 2.40GHz 4x Xeon E7340
|
Headers, Jumpers, LEDs, and Switches
LOCATION |
PINS |
SETTING |
DESCRIPTION |
J11 |
4 |
Out |
Unknown |
J19 |
2 |
Out |
Unknown |
J22 |
2 |
Out |
Unknown |
J23 |
2 |
Out |
Unknown |
J35 |
20 |
Out |
Unknown |
J37 |
2 |
Out |
Unknown |
J42
|
1-3 |
In |
NVRAM Clear |
3-5 |
Jumper storage position (default) |
2-4 |
Password Enable |
4-6 |
Jumper storage position (default) |
J44 |
2 |
Out |
Unknown |
J45 |
2 |
Out |
Unknown |
J46 |
2 |
Out |
Unknown |
J47 |
2 |
Out |
Unknown |
J48 |
2 |
Out |
Unknown |
J49 |
2 |
Out |
Unknown |
JP4 |
2-3 |
In |
Unknown (default) |
JP5 |
4 |
NA |
Unknown connector |
JP7 |
10 |
NA |
Unknown connector |
JP8 |
14 |
NA |
Unknown connector |
Sun Blade X6450 Codename: Hercules |
Notes
- The FRU does not include CPUs, Disks, Heatsinks, or Memory.
- Press Fault Remind button S3 to illuminate the CPU and DIMM fault LEDs.
- Install DIMMs in pairs of two beginning with A0/B0.
References
-
Sun Blade X6450 Installation Guide, 820-3535.
-
Sun Blade X6450 Service Manual, 820-3539.
-
Sun Blade X6450 Product Notes, 820-3538.
Sun Blade X6450
375-3601 |
540-7821 |
X6450-AB |
System Board
|
System Board FRU 375-3601 + Tray
w/o Processors w/o Heatsinks
|
X6450 Base 599-3548 w/o Processors
w/o Heatsinks
|
594-5766 |
594-5767 |
594-5768 |
594-5769 |
X6450-44L2131-82 16GB 2.13GHz 4x Xeon E7445
|
X6450-46L2131-82 16GB 2.13GHz 4x Xeon L7455
|
X6450-44M2401-82 16GB 2.40GHz 4x Xeon E7400
|
X6450-46M2401-B2 32GB 2.40GHz 4x Xeon E7450
|
Headers, Jumpers, LEDs, and Switches
LOCATION |
PINS |
SETTING |
DESCRIPTION |
J11 |
4 |
Out |
Unknown |
J19 |
2 |
Out |
Unknown |
J22 |
2 |
Out |
Unknown |
J23 |
2 |
Out |
Unknown |
J35 |
20 |
Out |
Unknown (not installed) |
J37 |
2 |
Out |
Unknown |
J42
|
1-3 |
In |
NVRAM Clear |
3-5 |
Jumper storage position (default) |
2-4 |
Password Enable |
4-6 |
Jumper storage position (default) |
J44 |
2 |
Out |
Unknown |
J45 |
2 |
Out |
Unknown |
J46 |
2 |
Out |
Unknown |
J47 |
2 |
Out |
Unknown |
J48 |
2 |
Out |
Unknown |
J49 |
2 |
Out |
Unknown |
J51 |
2-3 |
In |
Unknown (default) |
JP4 |
2-3 |
In |
Unknown (default) |
JP5 |
4 |
NA |
Unknown connector |
JP7 |
10 |
NA |
Unknown connector (not installed) |
JP8 |
14 |
NA |
Unknown connector |
Sun Blade X6450 Codename: Hercules 2.0 Mojo |
Notes
- The FRU does not include CPUs, Disks, Heatsinks, or Memory.
- Press Fault Remind button S3 to illuminate the CPU and DIMM fault LEDs.
- Install DIMMs in pairs of two beginning with A0/B0.
- System Board 375-3601 supports Low Voltage DIMMs and Solid-State Drives.
References
-
Sun Blade X6450 Installation Guide, 820-3535.
-
Sun Blade X6450 Service Manual, 820-3539.
-
Sun Blade X6450 Product Notes, 820-3538.
|