Sun Blade X6270
501-7918 |
541-2860 |
X6270-AA |
System Board |
Assembly/FRU 501-7918 |
X6270 Base 541-2860 |
Headers, Jumpers and Switches
LOCATION |
PINS |
SETTING |
DESCRIPTION |
J602 |
1-2 |
Out |
Not documented |
J603 |
1-2 |
Out |
Not documented |
J702 |
1-2 |
Out |
Not documented |
J705 |
1-2 |
Out |
Not documented |
J706 |
1-2 |
Out |
Not documented |
J901 |
1-3 |
Out |
Not documented |
J2402 |
1-2 |
In |
Not documented |
J2403 |
1-2 |
In |
Not documented |
J3402 |
1-3 |
Out |
Not documented |
J3403 |
1-3 |
Out |
Not documented |
J3404 |
1-3 |
Out |
Not documented |
J2601 |
2 |
Out |
Unknown Header |
J1402 |
5 |
n/a |
Unknown Header |
J1403 |
5 |
n/a |
REM Card |
J3301 |
10 |
n/a |
CPLD Program Header |
J3302 |
10 |
n/a |
CPLD Debug Header |
J5301 |
14 |
n/a |
Unknown Header |
SW2401 |
n/a |
n/a |
Clear CMOS Button |
SW3001 |
n/a |
n/a |
Fault Remind Button |
SW4601 |
n/a |
n/a |
Unknown Button |
SW4602 |
n/a |
n/a |
Unknown Button |
Sun Blade X6270 Server Module Codename: Virgo |
Notes
- The minimum Solaris operating system is Solaris 10 10/08.
- Heatsink FRU 541-2545 includes Heatsink 310-0161, two 240-6751 SpringScrews,
one 250-1802 Cleaning Wipe and one 310-0065 Shin-Etsu X23-7783D Thermal
Grease Syringe. Heatsink 310-0161 is pre-greased with Shin-Etsu G751.
- The System Board FRU includes two 250-1802 Cleaning Wipes, and
two 310-0065 Shin-Etsu X23-7783D Thermal Grease Syringes.
Chassis Notes
- The X6270 is supported in Sun Blade 6000 A90-A and A90-B, and
in Sun Blade 6048.
- The X6270 is not supported in Sun Blade 6000 A90-D.
Memory Installation Notes
- Install memory filler panel 350-1288 in all unused slots.
- Install the first three DIMMs in CPU0 and CPU1 slots D8, D5, and D2.
- Install the second three DIMMs in CPU0 and CPU1 slots D7, D4, and D1.
- Maximum speed is 1333MHz when 1333MHz DIMMs are installed in D8, D5, and D2.
- Maximum speed is 1066MHz when two DIMMs of any speed are installed
per channel.
- Maximum speed is 800MHz when three DIMMs of any speed are installed
per channel.
- Use of the same DIMM size and speed is recommended for maximum performance.
Midplane Notes
- The Sun Blade X6270 supports PCI Express 1.1 and 2.0.
- Sun Blade 6000 Midplane 501-7376 supports PCI Express 1.1.
- Sun Blade 6000 Midplane 511-1298 supports PCI Express 2.0.
- The Sun Blade 6000 Midplane upgrade is A90-B-MP-UPGKIT.
- Sun Blade 6048 Midplane 501-7788 supports PCI Express 1.1.
- Sun Blade 6048 Midplanes 511-1212 and 511-1473 support PCI Express 2.0.
- The Sun Blade 6048 Midplane upgrade is B22-B-MP-UPGKIT.
References
-
Sun Blade X6270 Installation Guide, 820-6175.
-
Sun Blade X6270 Service Manual, 820-6178.
-
Sun Blade X6270 Product Notes, 820-6179.
|