Sun Blade X6250
375-3501 |
540-7254 |
A93-AA |
594-4530 |
594-4531 |
594-4532 |
System Board
|
Assembly/FRU
|
X6250 Base 540-7254
|
X4361A 4GB 1.6GHz Xeon L5310 |
X4362A 8GB 1.86GHz Xeon E5320 |
X4363A 32GB 2.33GHz Xeon E5345 |
594-4533 |
594-4816 |
594-5282 |
594-5283 |
594-5284 |
X4364A 32GB 2.66GHz Xeon X5355 |
X4365A 32GB 3.0GHz Xeon 5160 |
X4367A 4GB 2.5GHz Xeon L5420 |
X4368A 4GB 2.33GHz Xeon E5410 |
X4369A 8GB 2.83GHz Xeon E5440 |
594-5672 |
594-5673 |
X6250-24L2660-22 4GB 2.66GHz Xeon L5430 |
X6250-24M2500-22 4GB 2.50GHz Xeon E5420 |
Headers, Jumpers, LEDs, and Switches
LOCATION |
PINS |
SETTING |
DESCRIPTION |
D12 |
n/a |
n/a |
PEM1 Power |
D14 |
n/a |
n/a |
PEM1 Attention |
D15 |
n/a |
n/a |
Ethernet Phy Activity |
D17 |
n/a |
n/a |
Ethernet Phy Link |
D18 |
n/a |
n/a |
PEM0 Power |
D21 |
n/a |
n/a |
PEM0 Attention |
D23 |
n/a |
n/a |
CPLD |
D25 |
n/a |
n/a |
NEM0 Power |
D27 |
n/a |
n/a |
NEM0 Attention |
D30 |
n/a |
n/a |
NEM1 Power |
D32 |
n/a |
n/a |
NEM1 Attention |
D34 |
n/a |
n/a |
BMC Heartbeat |
J19 |
1-2 |
Out |
Unknown |
J23 |
1-3 3-5 2-4 4-6 |
In In In In |
Clear CMOS Normal CMOS Operation (default)
Clear BIOS Password
(BugID 6742739)
Normal BIOS Operation (default) |
JP9 |
14 |
n/a |
Unused Connector |
JP11 |
3 |
n/a |
Unknown |
S1 |
n/a |
n/a |
Unknown Button |
S2 |
n/a |
n/a |
Unknown Button |
S4 |
n/a |
n/a |
CPU and DIMM Fault Locate Button |
Sun Blade X6250 Codename: Wolf |
Notes
- CPU 0 DIMM fault LEDs are located to the left and below each slot.
- CPU 1 DIMM fault LEDs are located to the left and above each slot.
- Press Fault Remind button S4 to illuminate the memory fault LEDs.
- The FRU includes Disk Backplanes and Cables, System Board, Enclosure, and
Cover.
- The FRU does not include CPUs, Disks, Heatsinks, or Memory.
- LEDs D12 through D34 are not visible when the blade is installed.
- LEDs D12 through D34 are not activated by the Fault Remind button.
Disk Backplane Notes
- The Disk Backplane, Data Cable, and Power Cable are not available as FRUs.
- Disk Backplane Data Cables and Power Cables do not have Sun part numbers.
- The Power Cable may be labeled 540-2479. This is a disk bracket released
in 1993.
- SAS configurations require RAID Expansion Module (REM) 371-2658.
- The REM supports RAID 0/1/5/10 with SAS disk drives.
- Use the system board SAS connectors for SAS/SATA/SSD drives connected
to any REM.
- Use the system board SATA connectors for SATA/SSD drives connected
without a REM.
RoHS Notes
- The Intel 6321ESB SL97P is a leaded component. The board is not .
- The PMC-Sierra PM8380-NI is a leaded component. The board is not .
References
-
Sun Blade X6250 Server Module Installation Guide, 820-1182.
-
Sun Blade X6250 Server Module Service Manual, 820-1185.
-
Sun Blade X6250 Server Module Product Notes, 820-1186.
|