Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



Sun Blade X6240

375-3558-01 540-7676 X6240-AA
System Board
Assembly/FRU
375-3558-01 + Enclosure
X6240 Base
540-7676
594-5567 594-5618 594-5382
8GB 1.9GHz
Opteron 2347HE
X6240-24L1900-42
16GB 2.1GHz
Opteron 2352
X6240-24M2100-42
16GB 2.3GHz
Opteron 2356
X6240-24M2300-82
594-5966 594-5964 594-5965
8GB 2.3GHz
Opteron 2376HE
X6240-24L2301-42
8GB 2.5GHz
Opteron 2380
X6240-24M2501-42
16GB 2.7GHz
Opteron 2384
X6240-24M2701-82

Headers and Jumpers

LOCATION PINS SETTING DESCRIPTION
J5 2 Out Not documented
J6 2 Out Not documented
J7 6 Out Not documented
J8 6 Out Not documented
J10 6 Out Not documented
J11 2 Out Not documented
J12 2 Out Not documented
J13 2 Out Not documented
J15 3 Out I2C 2nd Bus
J16 1-2 In Normal CMOS (2-3 = Clear CMOS)
J17 3 Out I2C Main Bus
J18 3 Out Not documented
J19 2-3 In Normal Password (1-2 = Clear SP Password)
J20 1-2 Out Write Protect (default)
J21 2-3 In Enable ARM (1-2 = Disable ARM)
J22 2-3 In Program by ILOM (default)
J23 4 Out Not documented
J24 2 Out Not documented
J25 2 Out Not documented
J26 2 n/a Not documented (not stuffed)
J72 16 n/a Power Debug Header
J75 20 n/a BMC JTAG Header
J81 1-2 In Normal (default)
J82 2-3 In Normal (default)
J83 1-2 Out SP Manfacturing Mode (default)
J84 1-2 Out SP TRST (default)
J87 2 Out Not documented
SW1 n/a n/a CPU and DIMM Fault Locate Button
SW7 n/a n/a Not documented

Sun Blade X6240 Server Module Codename: Gemini+

Notes

  1. The minimum Solaris operating system is Solaris 10 5/08.
  2. Press Fault Locate button SW1 to illuminate the CPU and DIMM fault LEDs.
  3. The FRU includes Disk Backplanes, Cables, System Board, Enclosure, and Cover.
  4. The FRU does not include CPUs, Disks, Heatsinks, or Memory.
  5. Thermal Grease 310-0065 is included with the Heatsink and System Board FRUs.
  6. Heatsink 310-0091 is pre-greased with ShinEtsu G751 (310-0049).
  7. Install DIMMs in D0/D1, then D2/D3, D4/D5, and D6/D7.

Disk Backplane Notes

  1. The 2-Slot Disk Backplane has no part number and is not available as a FRU.
  2. There is no Disk Backplane cable kit for the Sun Blade X6240.
  3. Use the system board SAS connectors for SAS/SATA/SSD drives connected to any REM.
  4. Use the system board SATA connectors for SATA/SSD drives connected without a REM.

References

  1. Sun Blade X6240 Server Module Installation Guide, 820-3968.
  2. Sun Blade X6240 Server Module Service Manual, 820-3971.
  3. Sun Blade X6240 Server Module Product Notes, 820-3972.


Sun Blade X6240


375-3624 542-0141 X6240-AB
System Board
Assembly/FRU
375-3624 + Enclosure
X6240 Base
542-0141

Headers and Jumpers

LOCATION PINS SETTING DESCRIPTION
J5 2 Out Not documented
J6 2 Out Not documented
J7 6 Out Not documented
J8 6 Out Not documented
J10 6 Out Not documented
J11 2 Out Not documented
J12 2 Out Not documented
J13 2 Out Not documented
J15 3 Out I2C 2nd Bus
J16 1-2 In Normal CMOS (2-3 = Clear CMOS)
J17 3 Out I2C Main Bus
J18 3 Out Not documented
J19 2-3 In Normal Password (1-2 = Clear SP Password)
J20 1-2 Out Write Protect (default)
J21 2-3 In Enable ARM (1-2 = Disable ARM)
J22 2-3 In Program by ILOM (default)
J23 4 Out Not documented
J24 2 Out Not documented
J25 2 Out Not documented
J26 2 n/a Not documented (not stuffed)
J72 16 n/a Power Debug Header
J75 20 n/a BMC JTAG Header
J81 1-2 In Normal (default)
J82 2-3 In Normal (default)
J83 1-2 Out SP Manfacturing Mode (default)
J84 1-2 Out SP TRST (default)
J87 2 Out Not documented
SW1 n/a n/a CPU and DIMM Fault Locate Button
SW7 n/a n/a Not documented

Sun Blade X6240 Server Module Codename: Gemini+ HT3

Notes

  1. The minimum Solaris operating system is Solaris 10 5/08.
  2. X6240-AB is required to support AMD 6-core Opteron 2400 series processors.
  3. System Board 542-0141 supports 8GB DIMMs and utilizes cHT3 (Coherent HyperTransport 3.0) technology.
  4. Press Fault Locate button SW1 to illuminate the CPU and DIMM fault LEDs.
  5. The FRU includes Disk Backplanes, Cables, System Board, Enclosure, and Cover.
  6. The FRU does not include CPUs, Disks, Heatsinks, or Memory.
  7. Thermal Grease 310-0065 is included with the Heatsink and System Board FRUs.
  8. Heatsink 310-0091 is pre-greased with ShinEtsu G751 (310-0049).
  9. Install DIMMs in D0/D1, then D2/D3, D4/D5, and D6/D7.

Disk Backplane Notes

  1. The 2-Slot Disk Backplane has no part number and is not available as a FRU.
  2. There is no Disk Backplane cable kit for the Sun Blade X6240.
  3. Use the system board SAS connectors for SAS/SATA/SSD drives connected to any REM.
  4. Use the system board SATA connectors for SATA/SSD drives connected without a REM.

References

  1. Sun Blade X6240 Server Module Installation Guide, 820-3968.
  2. Sun Blade X6240 Server Module Service Manual, 820-3971.
  3. Sun Blade X6240 Server Module Product Notes, 820-3972.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.