Sun Blade X6240
375-3558-01 |
540-7676 |
X6240-AA |
System Board
|
Assembly/FRU 375-3558-01 + Enclosure |
X6240 Base 540-7676 |
594-5567 |
594-5618 |
594-5382 |
8GB 1.9GHz Opteron 2347HE X6240-24L1900-42 |
16GB 2.1GHz Opteron 2352 X6240-24M2100-42 |
16GB 2.3GHz Opteron 2356 X6240-24M2300-82 |
594-5966 |
594-5964 |
594-5965 |
8GB 2.3GHz Opteron 2376HE X6240-24L2301-42 |
8GB 2.5GHz Opteron 2380 X6240-24M2501-42 |
16GB 2.7GHz Opteron 2384 X6240-24M2701-82 |
Headers and Jumpers
LOCATION |
PINS |
SETTING |
DESCRIPTION |
J5 |
2 |
Out |
Not documented |
J6 |
2 |
Out |
Not documented |
J7 |
6 |
Out |
Not documented |
J8 |
6 |
Out |
Not documented |
J10 |
6 |
Out |
Not documented |
J11 |
2 |
Out |
Not documented |
J12 |
2 |
Out |
Not documented |
J13 |
2 |
Out |
Not documented |
J15 |
3 |
Out |
I2C 2nd Bus |
J16 |
1-2 |
In |
Normal CMOS (2-3 = Clear CMOS) |
J17 |
3 |
Out |
I2C Main Bus |
J18 |
3 |
Out |
Not documented |
J19 |
2-3 |
In |
Normal Password (1-2 = Clear SP Password) |
J20 |
1-2 |
Out |
Write Protect (default) |
J21 |
2-3 |
In |
Enable ARM (1-2 = Disable ARM) |
J22 |
2-3 |
In |
Program by ILOM (default) |
J23 |
4 |
Out |
Not documented |
J24 |
2 |
Out |
Not documented |
J25 |
2 |
Out |
Not documented |
J26 |
2 |
n/a |
Not documented (not stuffed) |
J72 |
16 |
n/a |
Power Debug Header |
J75 |
20 |
n/a |
BMC JTAG Header |
J81 |
1-2 |
In |
Normal (default) |
J82 |
2-3 |
In |
Normal (default) |
J83 |
1-2 |
Out |
SP Manfacturing Mode (default) |
J84 |
1-2 |
Out |
SP TRST (default) |
J87 |
2 |
Out |
Not documented |
SW1 |
n/a |
n/a |
CPU and DIMM Fault Locate Button |
SW7 |
n/a |
n/a |
Not documented |
Sun Blade X6240 Server Module Codename: Gemini+ |
Notes
- The minimum Solaris operating system is Solaris 10 5/08.
- Press Fault Locate button SW1 to illuminate the CPU and DIMM fault LEDs.
- The FRU includes Disk Backplanes, Cables, System Board, Enclosure, and Cover.
- The FRU does not include CPUs, Disks, Heatsinks, or Memory.
- Thermal Grease 310-0065 is included with the Heatsink and System Board FRUs.
- Heatsink 310-0091 is pre-greased with ShinEtsu G751 (310-0049).
- Install DIMMs in D0/D1, then D2/D3, D4/D5, and D6/D7.
Disk Backplane Notes
- The 2-Slot Disk Backplane has no part number and is not available as a FRU.
- There is no Disk Backplane cable kit for the Sun Blade X6240.
- Use the system board SAS connectors for SAS/SATA/SSD drives connected to any REM.
- Use the system board SATA connectors for SATA/SSD drives connected without a REM.
References
-
Sun Blade X6240 Server Module Installation Guide, 820-3968.
-
Sun Blade X6240 Server Module Service Manual, 820-3971.
-
Sun Blade X6240 Server Module Product Notes, 820-3972.
Sun Blade X6240
375-3624 |
542-0141 |
X6240-AB |
System Board
|
Assembly/FRU 375-3624 + Enclosure |
X6240 Base 542-0141 |
Headers and Jumpers
LOCATION |
PINS |
SETTING |
DESCRIPTION |
J5 |
2 |
Out |
Not documented |
J6 |
2 |
Out |
Not documented |
J7 |
6 |
Out |
Not documented |
J8 |
6 |
Out |
Not documented |
J10 |
6 |
Out |
Not documented |
J11 |
2 |
Out |
Not documented |
J12 |
2 |
Out |
Not documented |
J13 |
2 |
Out |
Not documented |
J15 |
3 |
Out |
I2C 2nd Bus |
J16 |
1-2 |
In |
Normal CMOS (2-3 = Clear CMOS) |
J17 |
3 |
Out |
I2C Main Bus |
J18 |
3 |
Out |
Not documented |
J19 |
2-3 |
In |
Normal Password (1-2 = Clear SP Password) |
J20 |
1-2 |
Out |
Write Protect (default) |
J21 |
2-3 |
In |
Enable ARM (1-2 = Disable ARM) |
J22 |
2-3 |
In |
Program by ILOM (default) |
J23 |
4 |
Out |
Not documented |
J24 |
2 |
Out |
Not documented |
J25 |
2 |
Out |
Not documented |
J26 |
2 |
n/a |
Not documented (not stuffed) |
J72 |
16 |
n/a |
Power Debug Header |
J75 |
20 |
n/a |
BMC JTAG Header |
J81 |
1-2 |
In |
Normal (default) |
J82 |
2-3 |
In |
Normal (default) |
J83 |
1-2 |
Out |
SP Manfacturing Mode (default) |
J84 |
1-2 |
Out |
SP TRST (default) |
J87 |
2 |
Out |
Not documented |
SW1 |
n/a |
n/a |
CPU and DIMM Fault Locate Button |
SW7 |
n/a |
n/a |
Not documented |
Sun Blade X6240 Server Module Codename: Gemini+ HT3 |
Notes
- The minimum Solaris operating system is Solaris 10 5/08.
- X6240-AB is required to support AMD 6-core Opteron 2400 series processors.
- System Board 542-0141 supports 8GB DIMMs and
utilizes cHT3 (Coherent HyperTransport 3.0) technology.
- Press Fault Locate button SW1 to illuminate the CPU and DIMM fault LEDs.
- The FRU includes Disk Backplanes, Cables, System Board, Enclosure, and Cover.
- The FRU does not include CPUs, Disks, Heatsinks, or Memory.
- Thermal Grease 310-0065 is included with the Heatsink and System Board FRUs.
- Heatsink 310-0091 is pre-greased with ShinEtsu G751 (310-0049).
- Install DIMMs in D0/D1, then D2/D3, D4/D5, and D6/D7.
Disk Backplane Notes
- The 2-Slot Disk Backplane has no part number and is not available as a FRU.
- There is no Disk Backplane cable kit for the Sun Blade X6240.
- Use the system board SAS connectors for SAS/SATA/SSD drives connected to any REM.
- Use the system board SATA connectors for SATA/SSD drives connected without a REM.
References
-
Sun Blade X6240 Server Module Installation Guide, 820-3968.
-
Sun Blade X6240 Server Module Service Manual, 820-3971.
-
Sun Blade X6240 Server Module Product Notes, 820-3972.
|