StorEdge 5210 NAS / 5310 NAS
375-3209 |
PBA A99386-112 Intel SE7501WV2
370-6171 w/o BIOS/Firmware MAC Address 0007e9xxxxxx
|
Headers and Jumpers
LOCATION |
PINS |
SETTING |
DESCRIPTION |
J1A1 |
2 |
NA |
HDD LED - not used |
J1D3 |
10 |
NA |
USB Cable to LDC Module and Operator Panel |
J1G1 |
34 |
NA |
Floppy - not used |
J1G2 |
40 |
NA |
IDE - 256MB Flash Card 375-3214 |
J1G4 |
34 |
NA |
Front Panel - not used |
J1H1 |
24 |
NA |
NMI/RST/LED - not used |
J1J1 |
5 |
NA |
I2C to Power Distribution Board |
J2G1 |
6 |
NA |
Floppy/Front Panel/IDE |
J2J1 |
6 |
NA |
Fan Tray Power |
J3J1 |
24 |
NA |
Power to Power Distribution Board |
J3J2 |
12 |
NA |
Fan Tray Power |
J4J1 |
8 |
NA |
12V to Power Distribution Board |
J4J2 |
2 |
NA |
CPU1 Fan - not used |
J7A2 |
2 |
NA |
Chassis Int - not used |
J7B1 |
68 |
NA |
SCSI - not used |
J7J1 |
2 |
NA |
CPU2 Fan - not used |
J9A2 |
10 |
NA |
Serial Port A - not used |
J9B1 |
5 |
NA |
ICMB - not used |
J9C1 |
3 |
NA |
IPMB - not used |
J1D4 |
1-2 2-3 5-6 6-7 9-10 10-11 |
In In In In In In |
Normal CMOS Operation (default)
Clear CMOS
Normal Password Operation (default)
Clear Password
Normal BIOS Operation (default)
BIOS Recovery |
J4B2 |
1-2 2-3 |
Out In |
BMC Boot Block Write Enabled
BMC Boot Block Write Protected (default) |
J5A2 |
1-2 3-4 |
In In |
DCD connected to Serial Port Pin-7
DSR connected to Serial Port Pin-7 (default) |
StorEdge 5210 NAS Codename: Audi
StorEdge 5310 NAS Codename: Mustang |
Notes
- The System Board is not a Field Replacable Unit.
- The StorEdge 5210 NAS includes internal disk drives.
- The StorEdge 5310 NAS does not include internal disk drives.
References
-
StorEdge 5210 NAS Release Notes, 817-6657.
-
StorEdge 5210 NAS Quick Reference Manual, 817-6659.
-
StorEdge 5210 NAS Hardware Installation, Configuration, and User Guide, 817-6660.
-