Netra X4450
375-3510 |
540-7601 |
System Board
|
Assembly/FRU System Board + Tray
|
Jumpers
LOCATION |
PINS |
SETTING |
DESCRIPTION |
J33 |
1-3 |
In |
Clear NVRAM (temporary setting) |
J33 |
2-4 |
In |
Clear Password (temporary setting) |
J16 |
1-2 |
Out |
BMC Disable (default) |
J40 |
1-2 |
Out |
Unknown |
Netra X4450 Codename: Argo |
Notes
- The minimum Solaris operating system is Solaris 10 8/07.
- Heatsink 310-0185 is pregreased with Shin-Etsu X23-7783D.
- The System Board FRU includes a mounting tray, four 250-1802 Cleaning
Wipes, and four 310-0065 Thermal Grease Syringes.
- When removing the system board, unfasten the four green bus bar screws, not the
four silver bus bar screws that connect bus bar 341-4245 to the system board.
Firmware Notes
- MAXII CPLD code at U107 does not have a Sun part number
- BIOS code at U44 does not have a Sun part number.
- System Board 540-7601 includes ILOM. It was not manufactured with ELOM.
Memory Notes
- Install memory in matched pairs.
- Memory FRUs include two matched DIMMs.
- Sun Fire X4450 DIMMs are not labeled with the FRU part number.
- Install the largest capacity memory in the lowest numbered slots.
- Install the first DIMM pair in slots A0/B0. Install the second pair in slots C0/D0.
- Install additional memory in slots A1/B1, C1/D1, A2/B2, C2/D2, A3/B3, and C3/D3
A4/B4, C4/D4, A5/B5, C5/D5, A6/B6, C6/D6, A7/B7, and C7/D7.
- A 3mm allen wrench is required to remove the Memory Riser cap-head screws.
References
-
Netra X4450 Installation Guide, 820-4015.
-
Netra X4450 Service Manual, 820-4017.
-